SUN HYDRAULICS
PRDMXDV2C24V
$574.80 USD
Tags:
- SUN HYDRAULICS
- Material:PRDMXDV2C24V
- Model:PRDM-XDV@2C24V
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PRDMXDV2C24V (Material Number: PRDMXDV2C24V) is an electroproportional, direct-acting reducer-reliever valve designed to manage hydraulic pressure with precision and reliability. This valve effectively reduces high primary pressures at inlet port 2 to a constant, user-specified reduced pressure at port 1, while also providing a full flow relief function from port 1 to tank port 3. The valve's operation is biased towards the reducing mode, ensuring that port 2 connects to port 1 at the predefined pressure setting. By increasing the current to its coil, users can proportionally decrease the reduced pressure at port 1. Should the pressure exceed the coil-induced setting, it is relieved to port 3. The design of this valve features a slightly open transition from reducing to relieving modes, allowing for excellent pressure control and dynamic response with minimal oil consumption of approximately 0.1 gpm (0.4 L/min). To optimize performance, it is recommended to use an amplifier with current sensing and adjustable dither between 100-250 Hz. The valve supports interchangeable coils from Sun's solenoid-operated valves line and can be mounted in either direction on the tube. This model incorporates Sun's floating style construction which minimizes potential binding of internal parts due to installation torque or machining variations in cavities or cartridges. It is capable of operating under a maximum pressure of 5000 psi (350 bar) and features a direct acting concept that ensures reliable performance even in contaminated systems or dead-headed conditions. For applications requiring reverse flow from reduced pressure port 1 to inlet port 2, adding a separate check valve may be necessary as reverse flow could cause the main spool to close. Overall, this valve offers robust capabilities for applications requiring precise hydraulic pressure control with reliable performance characteristics across various conditions.
The Sun Hydraulics PRDMXDV2C24V (Material Number: PRDMXDV2C24V) is an electroproportional, direct-acting reducer-reliever valve designed to manage hydraulic pressure with precision and reliability. This valve effectively reduces high primary pressures at inlet port 2 to a constant, user-specified reduced pressure at port 1, while also providing a full flow relief function from port 1 to tank port 3. The valve's operation is biased towards the reducing mode, ensuring that port 2 connects to port 1 at the predefined pressure setting. By increasing the current to its coil, users can proportionally decrease the reduced pressure at port 1. Should the pressure exceed the coil-induced setting, it is relieved to port 3. The design of this valve features a slightly open transition from reducing to relieving modes, allowing for excellent pressure control and dynamic response with minimal oil consumption of approximately 0.1 gpm (0.4 L/min). To optimize performance, it is recommended to use an amplifier with current sensing and adjustable dither between 100-250 Hz. The valve supports interchangeable coils from Sun's solenoid-operated valves line and can be mounted in either direction on the tube. This model incorporates Sun's floating style construction which minimizes potential binding of internal parts due to installation torque or machining variations in cavities or cartridges. It is capable of operating under a maximum pressure of 5000 psi (350 bar) and features a direct acting concept that ensures reliable performance even in contaminated systems or dead-headed conditions. For applications requiring reverse flow from reduced pressure port 1 to inlet port 2, adding a separate check valve may be necessary as reverse flow could cause the main spool to close. Overall, this valve offers robust capabilities for applications requiring precise hydraulic pressure control with reliable performance characteristics across various conditions.
This electro-proportional, direct-acting reducer/reliever valve reduces a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full flow relief function from port 1 to tank (port 3). The valve is biased to the reducing mode, connecting port 2 to port 1 at a customer specified pressure setting. Increasing the current to the coil will proportionally decrease the reduced pressure at port 1. If pressure at port 1 exceeds the setting induced by the coil, pressure at port 1 is relieved to port 3. This valve is open in the transition from reducing to relieving. It provides good pressure control and dynamic response.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
- Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
- Direct acting concept provides highly reliable operation in contaminated systems, especially at dead headed conditions.
- The transition from reducing to relieving is slightly open. The result is very good pressure control with oil consumption of about 0.1 gpm (0,4 L/min.).
- For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
- Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
- With no electrical signal, the reduced pressure setting will default to the customer specified value. Increasing the command to the coil will proportionally reduce the secondary pressure value.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-11A |
| Series | 1 |
| Capacity | 5 gpm20 L/min. |
| Maximum Operating Pressure | 5000 psi350 bar |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 20 in³/min.330 cc/min. |
| Solenoid Tube Diameter | .75 in.19 mm |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Model Weight (with coil) | 1.20 lb0,55 kg |
| Seal kit - Cartridge | Viton: 990-511-006 |
| Seal and nut kit - Coil | Viton: 990-770-006Viton: 990-770-006 |
Show FAQ
Additional Resources
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Expands Corrosion-Resistant Solutions
- Sun Cartridges with EPDM Seals
- Weatherized Solenoid Valves for Harsh Environments
- Configure Your Bluetooth Embedded Amplifier with AmpSet Blue™
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Electro-Proportional Basics Explained
- Proportional Amplifiers and Ancillary Products
- Manufacturing Sun Cartridge Cavities
- Solenoid Coils for Switching and Proportional Valves
- Reducing and Reducing/Relieving Valves
- Electro-Proportional Cartridge Valves
- Electro-Proportional Terms and Definitions
- Cavity Information (S-171) and Tooling
- Sun's Floating Style Screw-In Cartridge
- Fluid and Temperature Recommendations
- Sun Model Code Explanation; 999-901-334
- Performance Data
- Cartridges: Materials of Construction
- Units of Measure, Settings, and Conversions