You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
PRDMXDN4F24V


$498.80 USD

Tags:

  • SUN HYDRAULICS
  • Material:PRDMXDN4F24V
  • Model:PRDM-XDN@4F24V
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PRDMXDN4F24V (PRDMXDN4F24V) is an electroproportional, direct-acting reducer-reliever valve designed to reduce a high primary pressure at inlet port 2 to a consistent reduced pressure at port 1. It features a full flow relief function from port 1 to tank port 3. The valve operates by connecting port 2 to port 1 at a predefined pressure setting, and increasing the current to the coil proportionally decreases the reduced pressure at port 1. If the pressure at port 1 exceeds this setting, it is relieved to port 3. The valve provides excellent pressure control and dynamic response due to its slightly open transition from reducing to relieving mode. It is highly reliable even in contaminated systems, especially during dead-headed conditions. This valve has a maximum operating pressure of 5000 psi (350 bar) and allows for direct additive pressures up to 3000 psi (210 bar) at port 3. For optimal performance, it is recommended that an amplifier with current sensing and adjustable dither between 100-250 Hz be used. The valve's coils are interchangeable with other Sun solenoid-operated valves and can be mounted in either direction on the tube. In scenarios where full reverse flow from reduced pressure port 1 to inlet port 2 is necessary, it is advisable to incorporate a separate check valve into the circuit as reverse flow may cause the main spool to close. The PRDMXDN4F24V incorporates Sun's floating style construction, minimizing the risk of internal parts binding due to excessive installation torque or cavity/cartridge machining variations. It fits into cavity T-11A with a series capacity of up to 5 gpm (20 L/min). The model weighs approximately 1.20 lb (0.55 kg) with coil included and comes with Viton seal kits for both cartridge and coil components.

This electro-proportional, direct-acting reducer/reliever valve reduces a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full flow relief function from port 1 to tank (port 3). The valve is biased to the reducing mode, connecting port 2 to port 1 at a customer specified pressure setting. Increasing the current to the coil will proportionally decrease the reduced pressure at port 1. If pressure at port 1 exceeds the setting induced by the coil, pressure at port 1 is relieved to port 3. This valve is open in the transition from reducing to relieving. It provides good pressure control and dynamic response.

  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • Direct acting concept provides highly reliable operation in contaminated systems, especially at dead headed conditions.
  • The transition from reducing to relieving is slightly open. The result is very good pressure control with oil consumption of about 0.1 gpm (0,4 L/min.).
  • For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
  • Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
  • With no electrical signal, the reduced pressure setting will default to the customer specified value. Increasing the command to the coil will proportionally reduce the secondary pressure value.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-11A
Series1
Capacity5 gpm20 L/min.
Maximum Operating Pressure5000 psi350 bar
Maximum Valve Leakage at 110 SUS (24 cSt)20 in³/min.330 cc/min.
Solenoid Tube Diameter.75 in.19 mm
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Model Weight (with coil)1.20 lb0,55 kg
Seal kit - CartridgeViton: 990-511-006
Seal and nut kit - CoilViton: 990-770-006Viton: 990-770-006

Show FAQ

Additional Resources