You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
PRDMXBV824


$284.10 USD

Tags:

  • SUN HYDRAULICS
  • Material:PRDMXBV824
  • Model:PRDM-XBV@824
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PRDMXBV824 (PRDMXBV824) is an electroproportional, direct-acting reducer-reliever valve designed to manage hydraulic pressure with precision and reliability. This valve reduces a high primary pressure at inlet port 2 to a consistent reduced pressure at port 1, featuring a full-flow relief function from port 1 to tank port 3. It operates in the reducing mode by default, linking port 2 to port 1 at a specified pressure setting determined by the customer. The valve's performance is enhanced by increasing current to the coil, which proportionally decreases the reduced pressure at port 1. Should pressure at port 1 surpass the coil-induced setting, it is relieved to port 3. Notably, this valve remains open during transitions from reducing to relieving, ensuring excellent pressure control and dynamic responsiveness. The maximum allowable pressure at port 3 is capped at 3000 psi (210 bar), contributing directly and additively to the valve setting. This direct-acting design offers reliable operation even in contaminated systems and dead-headed conditions. An amplifier with current sensing and adjustable dither between 100-250 Hz is recommended for optimal functionality. The interchangeable coils can be mounted on the tube in either direction, providing flexibility in installation. In scenarios requiring reverse flow from reduced pressure port 1 to inlet port 2, it is advised to incorporate a separate check valve into the circuit as reverse flow may cause the main spool to close. The Sun Hydraulics PRDMXBV824 incorporates floating style construction minimizing potential binding due to installation torque or machining variations. It fits into cavity T-11A with a capacity of up to 5 gpm (20 L/min) and can withstand a maximum operating pressure of up to 5000 psi (350 bar).

This electro-proportional, direct-acting reducer/reliever valve reduces a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full flow relief function from port 1 to tank (port 3). The valve is biased to the reducing mode, connecting port 2 to port 1 at a customer specified pressure setting. Increasing the current to the coil will proportionally decrease the reduced pressure at port 1. If pressure at port 1 exceeds the setting induced by the coil, pressure at port 1 is relieved to port 3. This valve is open in the transition from reducing to relieving. It provides good pressure control and dynamic response.

  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • Direct acting concept provides highly reliable operation in contaminated systems, especially at dead headed conditions.
  • The transition from reducing to relieving is slightly open. The result is very good pressure control with oil consumption of about 0.1 gpm (0,4 L/min.).
  • For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
  • Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
  • With no electrical signal, the reduced pressure setting will default to the customer specified value. Increasing the command to the coil will proportionally reduce the secondary pressure value.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-11A
Series1
Capacity5 gpm20 L/min.
Maximum Operating Pressure5000 psi350 bar
Maximum Valve Leakage at 110 SUS (24 cSt)20 in³/min.330 cc/min.
Solenoid Tube Diameter.75 in.19 mm
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Model Weight (with coil)1.20 lb0,55 kg
Seal kit - CartridgeViton: 990-511-006
Seal and nut kit - CoilViton: 990-770-006Viton: 990-770-006

Show FAQ

Additional Resources