SUN HYDRAULICS
PRDCLDN
$95.80 USD
Tags:
- SUN HYDRAULICS
- Material:PRDCLDN
- Model:PRDC-LDN
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PRDCLDN (Material Number: PRDCLDN) is a direct-acting pressure reducing valve designed to lower high primary pressures at the inlet port 2 to a consistent reduced pressure at port 1. This valve features a damped construction for stable operation and supports high reduced pressures, making it suitable for applications requiring precise pressure control and dynamic response. The transition from reducing to relieving is slightly open, resulting in efficient pressure regulation with an oil consumption of about 0.1 gpm (0.4 L/min). It is important to note that cartridges with EPDM seals are intended for systems using phosphate ester fluids, as exposure to petroleum-based fluids can damage the seals. The valve allows full reverse flow from reduced pressure port 1 to inlet port 2, which may cause the main spool to close; therefore, if reverse free flow is needed in the circuit, adding a separate check valve is advisable. Tested under conditions of up to 5000 psi (350 bar) inlet pressure, this direct-acting valve provides reliable performance even in contaminated systems and offers superior dynamic response compared to pilot-operated models. The pressure at port 3 adds directly to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar). With a maximum operating capacity of 10 gpm (40 L/min), this cartridge incorporates Sun's floating style construction to minimize internal part binding due to excessive installation torque or machining variations. The PRDCLDN model is physically interchangeable with all three-port pressure reducing and relieving cartridges for a given frame size. It has specific installation requirements such as torque specifications and seal kit compatibility, ensuring optimal performance in various hydraulic applications.
The Sun Hydraulics PRDCLDN (Material Number: PRDCLDN) is a direct-acting pressure reducing valve designed to lower high primary pressures at the inlet port 2 to a consistent reduced pressure at port 1. This valve features a damped construction for stable operation and supports high reduced pressures, making it suitable for applications requiring precise pressure control and dynamic response. The transition from reducing to relieving is slightly open, resulting in efficient pressure regulation with an oil consumption of about 0.1 gpm (0.4 L/min). It is important to note that cartridges with EPDM seals are intended for systems using phosphate ester fluids, as exposure to petroleum-based fluids can damage the seals. The valve allows full reverse flow from reduced pressure port 1 to inlet port 2, which may cause the main spool to close; therefore, if reverse free flow is needed in the circuit, adding a separate check valve is advisable. Tested under conditions of up to 5000 psi (350 bar) inlet pressure, this direct-acting valve provides reliable performance even in contaminated systems and offers superior dynamic response compared to pilot-operated models. The pressure at port 3 adds directly to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar). With a maximum operating capacity of 10 gpm (40 L/min), this cartridge incorporates Sun's floating style construction to minimize internal part binding due to excessive installation torque or machining variations. The PRDCLDN model is physically interchangeable with all three-port pressure reducing and relieving cartridges for a given frame size. It has specific installation requirements such as torque specifications and seal kit compatibility, ensuring optimal performance in various hydraulic applications.
Direct-acting, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1. These valves incorporate a damped construction for stable operation allowing the use of high reduced pressure. This valve is open in the transition from reducing to relieving. It provides good pressure control and dynamic response.
- The transition from reducing to relieving is slightly open. The result is very good pressure control with oil consumption of about 0.1 gpm (0,4 L/min.). The relatively high pilot control flow is only a factor in a dead-headed condition.
- Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- All spring ranges are tested for correct operation with 5000 psi (350 bar) inlet pressure.
- Direct acting concept provides highly reliable operation in contaminated systems, especially at dead headed conditions.
- Direct operated version offers superior dynamic response compared to equivalent pilot operated models.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Leakage specified in Technical Data is out of port 3 with a supply pressure of 2000 psi (140 bar) and the valve set at mid range. This leakage is directly proportional to pressure differential and inversely proportional to viscosity expressed in centistokes.
- All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-11A |
| Series | 1 |
| Capacity | 10 gpm40 L/min. |
| Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
| Maximum Operating Pressure | 5000 psi350 bar |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 20 in³/min.330 cc/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .30 lb0,15 kg |
| Seal kit - Cartridge | Viton: 990-011-006 |
Show FAQ
Additional Resources
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Sun Expands Corrosion-Resistant Solutions
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Manufacturing Sun Cartridge Cavities
- Reducing and Reducing/Relieving Valves
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
- Cartridges: Materials of Construction
- Fluid and Temperature Recommendations
- Performance Data
- Sun's Floating Style Screw-In Cartridge
Notes:
- For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.