PRDBCEV
$102.70 USD
Tags:
- SUN HYDRAULICS
- Material:PRDBCEV
- Model:PRDB-CEV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PRDBCEV (Material Number: PRDBCEV) is a direct-acting, pressure reducing/relieving valve designed to reduce high primary pressure at inlet port 2 to a constant reduced pressure at port 1, while offering a full-flow relief function from port 1 to tank port 3. This valve's damped construction ensures stable operation, even under high reduced pressure conditions. It is physically interchangeable with other three-port pressure reducing and relieving cartridges of the same frame size, facilitating easy integration into existing systems. The PRDBCEV valve is particularly suitable for accumulator circuits due to its direct acting concept, which minimizes secondary circuit leakage and enhances reliability in contaminated systems. With a capacity of 10 gpm (40 L/min) and maximum operating pressure of 5000 psi (350 bar), this valve is ideal for applications requiring precise pressure control. It features an adjustment range facilitated by an internal hex screw and locknut, allowing for fine-tuning of the pressure setting across its full range. The valve incorporates Sun's floating style construction to reduce the risk of internal parts binding due to installation torque or machining variations. Notably, the PRDBCEV model offers superior dynamic response compared to pilot-operated models and is tested for correct operation with an inlet pressure of up to 5000 psi. It also provides compatibility with EPDM seals for use in systems utilizing phosphate ester fluids, though care must be taken to avoid exposure to petroleum-based substances that could damage the seals. The design includes considerations for reverse flow scenarios and recommends integrating a separate check valve if reverse free flow from reduced pressure port 1 to inlet port 2 is necessary.
The Sun Hydraulics PRDBCEV (Material Number: PRDBCEV) is a direct-acting, pressure reducing/relieving valve designed to reduce high primary pressure at inlet port 2 to a constant reduced pressure at port 1, while offering a full-flow relief function from port 1 to tank port 3. This valve's damped construction ensures stable operation, even under high reduced pressure conditions. It is physically interchangeable with other three-port pressure reducing and relieving cartridges of the same frame size, facilitating easy integration into existing systems. The PRDBCEV valve is particularly suitable for accumulator circuits due to its direct acting concept, which minimizes secondary circuit leakage and enhances reliability in contaminated systems. With a capacity of 10 gpm (40 L/min) and maximum operating pressure of 5000 psi (350 bar), this valve is ideal for applications requiring precise pressure control. It features an adjustment range facilitated by an internal hex screw and locknut, allowing for fine-tuning of the pressure setting across its full range. The valve incorporates Sun's floating style construction to reduce the risk of internal parts binding due to installation torque or machining variations. Notably, the PRDBCEV model offers superior dynamic response compared to pilot-operated models and is tested for correct operation with an inlet pressure of up to 5000 psi. It also provides compatibility with EPDM seals for use in systems utilizing phosphate ester fluids, though care must be taken to avoid exposure to petroleum-based substances that could damage the seals. The design includes considerations for reverse flow scenarios and recommends integrating a separate check valve if reverse free flow from reduced pressure port 1 to inlet port 2 is necessary.
Direct-acting, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). These valves incorporate a damped construction for stable operation allowing the use of high reduced pressure.
- All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- All spring ranges are tested for correct operation with 5000 psi (350 bar) inlet pressure.
- Suitable for accumulator circuits since the absence of pilot control flow results in reduced secondary circuit leakage.
- Direct acting concept provides highly reliable operation in contaminated systems, especially at dead headed conditions.
- Unlike pilot operated versions, direct acting valves exhibit a transitional step between reducing and relieving modes. This step equals 5% of the high end of the adjustment range, independent of the valve setting. Therefore, these valves may not be suitable for counterbalancing applications.
- Direct operated version offers superior dynamic response compared to equivalent pilot operated models.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Leakage specified in Technical Data is out of port 3 with a supply pressure of 2000 psi (140 bar) and the valve set at mid range. This leakage is directly proportional to pressure differential and inversely proportional to viscosity expressed in centistokes.
- W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
- Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-11A |
| Series | 1 |
| Capacity | 10 gpm40 L/min. |
| Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
| Maximum Operating Pressure | 5000 psi350 bar |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 2 in³/min.30 cc/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .30 lb0,15 kg |
| Seal kit - Cartridge | Viton: 990-011-006 |
Show FAQ
Additional Resources
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Sun Expands Corrosion-Resistant Solutions
- Reduce Cylinder Decompression Shock and Cost of Ownership
- Manufacturing Sun Cartridge Cavities
- Reducing and Reducing/Relieving Valves
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
- Cartridges: Materials of Construction
- Fluid and Temperature Recommendations
Notes:
- For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.