You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
PPJFLNV


$601.40 USD

Tags:

  • SUN HYDRAULICS
  • Material:PPJFLNV
  • Model:PPJF-LNV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PPJFLNV (PPJFLNV) is a pilot-operated, pressure reducing-relieving valve designed to manage high primary pressure at the inlet port 2 by reducing it to a constant lower pressure at port 1, while offering a full-flow relief function from port 1 to tank port 3. This valve features a main stage orifice drilled directly into the piston, enhancing its durability for physically demanding applications. The maximum allowable pressure at port 3 is capped at 3000 psi (210 bar). Pressure at this port adds directly to the valve setting in a 1:1 ratio, and exceeding this limit is not recommended. While pilot-operated valves like this one are known for their stability and low hysteresis, they are not as fast-acting as direct-acting valves. The recommended maximum inlet pressure depends on the adjustment range, with different ranges supporting varying maximum differentials between inlet and reduced pressures. Notably, full reverse flow from reduced pressure port 1 to inlet port 2 can cause the main spool to close; hence, adding a separate check valve is advisable if reverse free flow is needed. For applications where pilot flow consumption is critical, direct acting reducing-relieving valves should be considered. This valve incorporates Sun's floating style construction to minimize internal binding risks due to excessive installation torque or machining variations. It fits into cavity T-19A and supports up to an 80 gpm (320 L/min) capacity with a maximum operating pressure of 5000 psi (350 bar). Adjustments can be made via an internal hex screw with specific torque requirements for both installation and locknut adjustments. The valve weighs approximately 3.10 lb (1.40 kg) and requires Viton seal kit number 990019006 for maintenance purposes.

Pilot-operated, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3).

  • These valves have the main stage orifice drilled into the piston rather than a staked-in orifice. This allows the valve to survive physically demanding applications.
  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-19A
Series4
Capacity80 gpm320 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow15 - 20 in³/min.0,25 - 0,33 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 5/8 in.41,3 mm
Valve Installation Torque350 - 375 lbf ft474 - 508 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight3.10 lb1,40 kg
Seal kit - CartridgeViton: 990-019-006

Show FAQ

Additional Resources