You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
PPJFKNN


$607.40 USD

Tags:

  • SUN HYDRAULICS
  • Material:PPJFKNN
  • Model:PPJF-KNN
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PPJFKNN (PPJFKNN) is a pilot-operated, pressure-reducing and relieving valve designed to manage high primary pressures at the inlet port 2, reducing them to a constant lower pressure at port 1, while providing a full-flow relief function from port 1 to tank port 3. This valve features a main stage orifice drilled into the piston, enhancing its durability in demanding applications. The maximum pressure at port 3 should not exceed 3000 psi (210 bar), as it directly adds to the valve setting at a 1:1 ratio. It is important to note that these pilot-operated valves are not fast-acting; for superior dynamic response, direct-acting valves are recommended. The recommended maximum inlet pressure varies by adjustment range: D, E, N, and Q ranges are tested with a 2000 psi (140 bar) differential; A, B, and H ranges with a 3000 psi (210 bar) differential; and C and W ranges with up to 5000 psi (350 bar). These valves exhibit stable performance with low hysteresis and flat pressure-flow characteristics. For circuits requiring reverse free flow from reduced pressure port 1 to inlet port 2, an additional check valve may be necessary. If pilot flow consumption is critical, direct-acting valves should be considered. The PPJFKNN model incorporates Sun's floating style construction to minimize internal binding due to installation torque or machining variations. It fits into cavity T-19A/Series 4 with an operating capacity of up to 80 gpm (320 L/min) and can handle pressures up to 5000 psi (350 bar). The control pilot flow ranges from 15\u201320 in\u00b3/min (0.25\u20130.33 L/min), with adjustments made via an internal hex screw size of 5/32 inch (4 mm).

Pilot-operated, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3).

  • These valves have the main stage orifice drilled into the piston rather than a staked-in orifice. This allows the valve to survive physically demanding applications.
  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-19A
Series4
Capacity80 gpm320 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow15 - 20 in³/min.0,25 - 0,33 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 5/8 in.41,3 mm
Valve Installation Torque350 - 375 lbf ft474 - 508 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight3.10 lb1,40 kg
Seal kit - CartridgeViton: 990-019-006

Show FAQ

Additional Resources