You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
PPJFCDV


$609.40 USD

Tags:

  • SUN HYDRAULICS
  • Material:PPJFCDV
  • Model:PPJF-CDV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PPJFCDV (PPJFCDV) is a pilot-operated, pressure reducing-relieving valve designed to maintain a constant reduced pressure at port 1 from a higher primary pressure at inlet port 2. It features a full-flow relief function from port 1 to tank port 3. Notably, the valve's main stage orifice is drilled into the piston, enhancing its durability for demanding applications. The maximum pressure at port 3 should not exceed 3000 psi (210 bar), and this pressure is directly additive to the valve setting at a 1:1 ratio. Although pilot-operated reducing-relieving valves are not fast-acting, they offer exceptionally stable performance with low hysteresis and flat pressure-flow characteristics. These valves are interchangeable within their series due to consistent flow paths and cavity sizes, making them versatile for various configurations. They are constructed with Sun's floating style design to minimize internal part binding due to installation torque or machining variations. The PPJFCDV model can handle a maximum operating pressure of up to 5000 psi (350 bar) and has a factory-set control pilot flow of 15-20 in\u00b3/min (0.25-0.33 L/min). The valve incorporates an adjustment mechanism allowing up to 5.5 clockwise turns for setting increases, with specific torque requirements for installation and locknut adjustments. The PPJFCDV model weighs approximately 3.10 lb (1.40 kg) and comes with Viton seal kits available for maintenance needs. This valve is suitable for applications requiring precise pressure regulation while handling high flow capacities up to 80 gpm (320 L/min). If reverse free flow is necessary in the circuit, users should consider adding a separate check valve as reverse flow may cause the main spool to close unexpectedly.

Pilot-operated, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3).

  • These valves have the main stage orifice drilled into the piston rather than a staked-in orifice. This allows the valve to survive physically demanding applications.
  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-19A
Series4
Capacity80 gpm320 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow15 - 20 in³/min.0,25 - 0,33 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 5/8 in.41,3 mm
Valve Installation Torque350 - 375 lbf ft474 - 508 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight3.10 lb1,40 kg
Seal kit - CartridgeViton: 990-019-006

Show FAQ

Additional Resources