SUN HYDRAULICS
PPHFLNV
$264.40 USD
Tags:
- SUN HYDRAULICS
- Material:PPHFLNV
- Model:PPHF-LNV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PPHFLNV (PPHFLNV) is a pilot-operated, pressure reducing-relieving valve designed to reduce high primary pressure at inlet port 2 to a constant reduced pressure at port 1, while providing a full-flow relief function from port 1 to tank port 3. This valve features the main stage orifice drilled into the piston, enhancing its durability in physically demanding applications. The pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar). The maximum recommended inlet pressure varies depending on the adjustment range: ranges D, E, N, and Q are tested with a maximum differential of 2000 psi (140 bar), while ranges A, B, and H handle up to 3000 psi (210 bar), and ranges C and W can withstand inlet pressures of up to 5000 psi (350 bar). The valve is known for its exceptionally flat pressure-flow characteristics, stability, and low hysteresis. It incorporates Sun's floating style construction to minimize internal parts binding due to excessive installation torque or machining variations. The valve is physically interchangeable with other three-port reducing and reducing-relieving cartridges of the same frame size. For applications requiring reverse flow from reduced pressure port 1 to inlet port 2, it may be necessary to add a separate check valve in the circuit. If pilot flow consumption or superior dynamic response is critical, direct acting valves may be preferred over pilot-operated ones. The PPHFLNV features a cavity type T-17A with series-3 capacity for up to 40 gpm (160 L/min) flow rates. It has a factory-set maximum operating pressure of 5000 psi (350 bar) with control pilot flow between 15-20 in\u00b3/min (0.25-0.33 L/min). Installation requires specific torque settings for various components such as locknuts and adjustment screws.
The Sun Hydraulics PPHFLNV (PPHFLNV) is a pilot-operated, pressure reducing-relieving valve designed to reduce high primary pressure at inlet port 2 to a constant reduced pressure at port 1, while providing a full-flow relief function from port 1 to tank port 3. This valve features the main stage orifice drilled into the piston, enhancing its durability in physically demanding applications. The pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar). The maximum recommended inlet pressure varies depending on the adjustment range: ranges D, E, N, and Q are tested with a maximum differential of 2000 psi (140 bar), while ranges A, B, and H handle up to 3000 psi (210 bar), and ranges C and W can withstand inlet pressures of up to 5000 psi (350 bar). The valve is known for its exceptionally flat pressure-flow characteristics, stability, and low hysteresis. It incorporates Sun's floating style construction to minimize internal parts binding due to excessive installation torque or machining variations. The valve is physically interchangeable with other three-port reducing and reducing-relieving cartridges of the same frame size. For applications requiring reverse flow from reduced pressure port 1 to inlet port 2, it may be necessary to add a separate check valve in the circuit. If pilot flow consumption or superior dynamic response is critical, direct acting valves may be preferred over pilot-operated ones. The PPHFLNV features a cavity type T-17A with series-3 capacity for up to 40 gpm (160 L/min) flow rates. It has a factory-set maximum operating pressure of 5000 psi (350 bar) with control pilot flow between 15-20 in\u00b3/min (0.25-0.33 L/min). Installation requires specific torque settings for various components such as locknuts and adjustment screws.
Pilot-operated, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3).
- These valves have the main stage orifice drilled into the piston rather than a staked-in orifice. This allows the valve to survive physically demanding applications.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
- Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
- Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
- Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
- Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
- All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-17A |
| Series | 3 |
| Capacity | 40 gpm160 L/min. |
| Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
| Maximum Operating Pressure | 5000 psi350 bar |
| Control Pilot Flow | 15 - 20 in³/min.0,25 - 0,33 L/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 1 1/4 in.31,8 mm |
| Valve Installation Torque | 150 - 160 lbf ft203 - 217 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | 1.30 lb0,60 kg |
| Seal kit - Cartridge | Viton: 990-017-006 |
Show FAQ
Additional Resources
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Sun Expands Corrosion-Resistant Solutions
- Manufacturing Sun Cartridge Cavities
- Reducing and Reducing/Relieving Valves
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
- Cartridges: Materials of Construction
- Fluid and Temperature Recommendations