SUN HYDRAULICS
PPHBQCN
$272.70 USD
Tags:
- SUN HYDRAULICS
- Material:PPHBQCN
- Model:PPHB-QCN
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PPHBQCN (PPHBQCN) is a pilot-operated, pressure-reducing and relieving valve designed to maintain a constant reduced pressure at port 1 while offering a full-flow relief function from port 1 to tank port 3. This valve is capable of reducing high primary pressure at inlet port 2 effectively. A key feature of this valve is its ability to add pressure at port 3 directly to the valve setting at a 1:1 ratio, with a maximum allowable pressure of 3000 psi (210 bar) at this port. The recommended maximum inlet pressure varies based on the adjustment range, with ranges C and W tested up to an inlet pressure of 5000 psi (350 bar). It exhibits exceptionally flat pressure-flow characteristics, ensuring stability and low hysteresis, though it is not as fast-acting as direct-acting valves. The PPHBQCN model incorporates Sun Hydraulics' floating style construction which helps prevent internal parts from binding due to excessive installation torque or machining variations. It supports a maximum operating pressure of 5000 psi (350 bar) and has a control pilot flow rate between 15-20 in\u00b3/min (0.25-0.33 L/min). The valve features an adjustable setting that can be increased by turning the adjustment screw clockwise up to 5.5 turns. This model also offers compatibility with systems using phosphate ester fluids when configured with EPDM seals, although exposure to petroleum-based fluids could damage these seals. Interchangeable with other three-port reducing and relieving cartridges, it allows for various mounting configurations and applications where full capacity return line usage might be necessary. Additionally, the design supports reverse flow from reduced pressure port 1 back to inlet port 2 but may require an additional check valve for optimal circuit performance if reverse free flow is necessary.
The Sun Hydraulics PPHBQCN (PPHBQCN) is a pilot-operated, pressure-reducing and relieving valve designed to maintain a constant reduced pressure at port 1 while offering a full-flow relief function from port 1 to tank port 3. This valve is capable of reducing high primary pressure at inlet port 2 effectively. A key feature of this valve is its ability to add pressure at port 3 directly to the valve setting at a 1:1 ratio, with a maximum allowable pressure of 3000 psi (210 bar) at this port. The recommended maximum inlet pressure varies based on the adjustment range, with ranges C and W tested up to an inlet pressure of 5000 psi (350 bar). It exhibits exceptionally flat pressure-flow characteristics, ensuring stability and low hysteresis, though it is not as fast-acting as direct-acting valves. The PPHBQCN model incorporates Sun Hydraulics' floating style construction which helps prevent internal parts from binding due to excessive installation torque or machining variations. It supports a maximum operating pressure of 5000 psi (350 bar) and has a control pilot flow rate between 15-20 in\u00b3/min (0.25-0.33 L/min). The valve features an adjustable setting that can be increased by turning the adjustment screw clockwise up to 5.5 turns. This model also offers compatibility with systems using phosphate ester fluids when configured with EPDM seals, although exposure to petroleum-based fluids could damage these seals. Interchangeable with other three-port reducing and relieving cartridges, it allows for various mounting configurations and applications where full capacity return line usage might be necessary. Additionally, the design supports reverse flow from reduced pressure port 1 back to inlet port 2 but may require an additional check valve for optimal circuit performance if reverse free flow is necessary.
Pilot-operated, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3).
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
- Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
- Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
- Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
- Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
- W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
- Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
- All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-17A |
| Series | 3 |
| Capacity | 40 gpm160 L/min. |
| Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
| Maximum Operating Pressure | 5000 psi350 bar |
| Control Pilot Flow | 15 - 20 in³/min.0,25 - 0,33 L/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 1 1/4 in.31,8 mm |
| Valve Installation Torque | 150 - 160 lbf ft203 - 217 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | 1.30 lb0,60 kg |
| Seal kit - Cartridge | Viton: 990-017-006 |
Show FAQ
Additional Resources
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Sun Expands Corrosion-Resistant Solutions
- Manufacturing Sun Cartridge Cavities
- Reducing and Reducing/Relieving Valves
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
- Cartridges: Materials of Construction
- Fluid and Temperature Recommendations
Notes:
- Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) N and Q are 2000 psi (140 bar) W is 5000 psi (350 bar)inlet pressure