You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
PPDF8WN


$90.20 USD

Tags:

  • SUN HYDRAULICS
  • Material:PPDF8WN
  • Model:PPDF-8WN
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PPDF8WN (Material Number: PPDF8WN) is a versatile 3-way, normally open modulating valve designed to incorporate an integral pilot control cavity, accommodating any T8A pressure control cartridge. This valve is engineered to reduce high primary pressure at inlet port 2 to a consistent reduced pressure at port 1, while offering full flow relief from port 1 to tank port 3. The setting of the pilot cartridge dictates the pressure differential between reduced pressure port 1 and tank port 3. Notably, the main stage orifice is drilled into the piston, enhancing durability in demanding applications. Pressure at port 3 adds directly to the valve setting in a 1:1 ratio, with a maximum allowable pressure of 3000 psi (210 bar). The maximum inlet pressure is contingent upon the bias spring used; the D spring supports up to 2000 psi (140 bar) differential pressure, and the W spring accommodates up to 5000 psi (350 bar) inlet pressure. The valve's design allows for straightforward integration of pilot control cartridges via the T8A cavity, which are available separately in various operational modes such as electro-proportional and solenoid. All three-port reducing and reducing-relieving cartridges share physical interchangeability for compatibility across configurations. For optimal performance in circuits requiring reverse free flow from reduced pressure port 1 to inlet port 2, adding a separate check valve is recommended. This pilot-operated valve exhibits minimal deadband transition between reducing and relieving modes and maintains stable performance with low hysteresis due to its exceptionally flat pressure-flow characteristics. Its floating style construction minimizes risks of internal binding from excessive installation torque or machining variations. Key specifications include a capacity of 10 gpm (40 L/min), maximum operating pressure of 5000 psi (350 bar), and necessary installation torques for both main stage and pilot control valves.

This valve is a 3-way, normally open modulating element that incorporates an integral pilot control cavity. The pilot control cavity will accept any T-8A pressure control cartridge. The valve reduces a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full flow relief function from port 1 to tank (port 3). The pilot cartridge's setting determines the difference in pressure between reduced pressure (port 1) and the tank (port 3).

  • These valves have the main stage orifice drilled into the piston rather than a staked-in orifice. This allows the valve to survive physically demanding applications.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Maximum inlet pressure is determined by the bias spring. The D spring is tested with 2000 psi (140 bar) maximum differential pressure and the W spring is tested with 5000 psi (350 bar) maximum inlet pressure.
  • NOTE: With the -8 control option, the main stage valve should first be installed to the correct torque value. The T-8A pilot control valve should then be installed into the main stage valve to its required torque value.
  • The -8 control option allows the pilot control valve to be incorporated directly into the end of the relief cartridge via the T-8A cavity. These pilot control cartridges are sold separately and include electro-proportional, solenoid, air pilot, and hydraulic pilot operation. See Pilot Control Cartridges.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • Pilot operated valves exhibit very low dead-band transition between reducing and relieving modes.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-11A
Series1
Capacity10 gpm40 L/min.
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow7 - 10 in³/min.0,11 - 0,16 L/min.
Pilot Control CavityT-8AT-8A
Pilot Control Valve Installation Torque20 - 25 lbf ft27 - 33 Nm
Pilot Control Valve Hex Size7/8 in.22,2 mm
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Model Weight.30 lb0,15 kg
Seal kit - CartridgeViton: 990-011-006

Show FAQ

Additional Resources



Notes:
  • Compound cartridge (pilot and main stage) assembly information is provided for reference only. Cartridges must be ordered separately and assembled at point of use.