***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PPDBMHV (Material Number: PPDBMHV) is a pilot-operated, pressure reducing-relieving valve designed to manage high primary pressures at the inlet port 2, ensuring a consistent reduced pressure at port 1 while offering a full-flow relief function from port 1 to tank port 3. These three-port cartridges are interchangeable, maintaining the same flow path and cavity for a given frame size. The valve's maximum inlet pressure is contingent on the adjustment range, with specific ranges tested up to different maximum differentials between inlet and reduced pressures. This valve excels in providing exceptionally flat pressure-flow characteristics, stability, and low hysteresis. It is crucial to note that while pilot-operated valves are not fast-acting, they can be adjusted throughout their full range using W or Y controls unless specified otherwise. The valve incorporates Sun's floating style construction to minimize internal binding due to installation torque or machining variations. The PPDBMHV model supports a maximum operating pressure of 5000 psi (350 bar) with a control pilot flow ranging from 7 to 10 in\u00b3/min (0.11 to 0.16 L/min). The valve's installation torque ranges from 30 to 35 lbf\u00b7ft (41 to 47 Nm), and it requires specific hex sizes for adjustment and locknut operations. Additionally, cartridges configured with EPDM seals are suitable for systems using phosphate ester fluids but are incompatible with petroleum-based fluids. This product is designed for use in hydraulic circuits where precise pressure regulation is necessary, offering reliable performance under specified conditions and configurations.
The Sun Hydraulics PPDBMHV (Material Number: PPDBMHV) is a pilot-operated, pressure reducing-relieving valve designed to manage high primary pressures at the inlet port 2, ensuring a consistent reduced pressure at port 1 while offering a full-flow relief function from port 1 to tank port 3. These three-port cartridges are interchangeable, maintaining the same flow path and cavity for a given frame size. The valve's maximum inlet pressure is contingent on the adjustment range, with specific ranges tested up to different maximum differentials between inlet and reduced pressures. This valve excels in providing exceptionally flat pressure-flow characteristics, stability, and low hysteresis. It is crucial to note that while pilot-operated valves are not fast-acting, they can be adjusted throughout their full range using W or Y controls unless specified otherwise. The valve incorporates Sun's floating style construction to minimize internal binding due to installation torque or machining variations. The PPDBMHV model supports a maximum operating pressure of 5000 psi (350 bar) with a control pilot flow ranging from 7 to 10 in\u00b3/min (0.11 to 0.16 L/min). The valve's installation torque ranges from 30 to 35 lbf\u00b7ft (41 to 47 Nm), and it requires specific hex sizes for adjustment and locknut operations. Additionally, cartridges configured with EPDM seals are suitable for systems using phosphate ester fluids but are incompatible with petroleum-based fluids. This product is designed for use in hydraulic circuits where precise pressure regulation is necessary, offering reliable performance under specified conditions and configurations.
Pilot-operated, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3).
- All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
- Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
- Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
- W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
- Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-11A |
| Series | 1 |
| Capacity | 10 gpm40 L/min. |
| Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
| Maximum Operating Pressure | 5000 psi350 bar |
| Control Pilot Flow | 7 - 10 in³/min.0,11 - 0,16 L/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .30 lb0,15 kg |
| Seal kit - Cartridge | Viton: 990-011-006 |
Show FAQ
Additional Resources
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Sun Expands Corrosion-Resistant Solutions
- Manufacturing Sun Cartridge Cavities
- Reducing and Reducing/Relieving Valves
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
- Cartridges: Materials of Construction
- Fluid and Temperature Recommendations
Notes:
- Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) N and Q are 2000 psi (140 bar) W is 5000 psi (350 bar)inlet pressure
- For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.