You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
PPDBLCN


$85.70 USD

Tags:

  • SUN HYDRAULICS
  • Material:PPDBLCN
  • Model:PPDB-LCN
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PPDBLCN (PPDBLCN) is a pilot-operated, pressure-reducing and relieving valve designed to manage high primary pressures by reducing them to a consistent lower pressure, while also providing a full-flow relief function. This valve operates between three ports: the inlet port 2, reduced pressure port 1, and tank port 3. It is interchangeable with other three-port pressure reducing and relieving cartridges of the same frame size, offering flexibility in mounting configurations. The valve's design allows for reverse flow from port 1 to port 2; however, for circuits requiring reverse free flow, an additional check valve should be considered. This model demonstrates exceptionally stable performance with low hysteresis due to its flat pressure-flow characteristics. The PPDBLCN can handle maximum operating pressures of up to 5000 psi (350 bar) and is tested across various adjustment ranges with different maximum differentials. Notably, the valve features Sun's floating style construction which minimizes internal part binding risks during installation or due to machining variations. The PPDBLCN incorporates EPDM seals suitable for phosphate ester fluids but should not be exposed to petroleum-based fluids as this will damage the seals. It is designed with a Cavity T-11A Series 1 capacity capable of handling flows up to 10 gpm (40 L/min). Installation requires specific torque settings and adjustments are made via an internal hex screw. For applications needing superior dynamic response or critical pilot flow consumption considerations, direct-acting valves may be preferable over this pilot-operated model. Overall, the Sun Hydraulics PPDBLCN provides reliable pressure control in hydraulic systems where precise regulation between high inlet pressures and reduced outlet pressures is crucial.

Pilot-operated, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3).

  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-11A
Series1
Capacity10 gpm40 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow7 - 10 in³/min.0,11 - 0,16 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.30 lb0,15 kg
Seal kit - CartridgeViton: 990-011-006

Show FAQ

Additional Resources



Notes:
  • Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) N and Q are 2000 psi (140 bar) W is 5000 psi (350 bar)inlet pressure
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.