FRFAKAV
$390.50 USD
Tags:
- SUN HYDRAULICS
- Material:FRFAKAV
- Model:FRFA-KAV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics FRFAKAV (Material Number: FRFAKAV) is a bypass-restrictive, fixed-orifice, priority flow control valve designed to manage hydraulic flow efficiently by directing input flow at port 1 to satisfy the priority flow at port 3. If the input flow surpasses the required priority flow, the excess is diverted through port 2 for use in secondary circuits. Users can specify a flow rating, with factory settings precise within a 10% range of the requested specification. The valve allows a maximum pressure of 3000 psi (210 bar) at port 3 and features an adjustable control option that permits up to a 22% variation from the nominal preset flow using an internal adjustment screw. Both priority and bypass flows are usable up to system operating pressures, maintaining relatively constant priority regardless of input variations. The sharp-edged orifice design minimizes viscosity-induced flow variations, while Sun's floating style construction reduces risks of internal part binding. It fits into cavity T19A, belongs to series 4, and has a capacity of up to 50 gpm (200 L/min). Its maximum operating pressure is rated at 5000 psi (350 bar), with an input flow capacity reaching up to 120 gpm (480 L/min). The valve's hex size measures 1-5/8 inches (41.3 mm), requiring installation torque between 350-375 lbf ft (475-508 Nm). The adjustment screw has an internal hex size of 5/32 inches (4 mm), while the locknut hex size is set at 9/16 inches (15 mm), with torque specifications ranging from 80-90 lbf in (9-10 Nm). Weighing approximately 2.70 lb (1.25 kg), this model includes a Viton seal kit for enhanced durability and performance in hydraulic systems.
The Sun Hydraulics FRFAKAV (Material Number: FRFAKAV) is a bypass-restrictive, fixed-orifice, priority flow control valve designed to manage hydraulic flow efficiently by directing input flow at port 1 to satisfy the priority flow at port 3. If the input flow surpasses the required priority flow, the excess is diverted through port 2 for use in secondary circuits. Users can specify a flow rating, with factory settings precise within a 10% range of the requested specification. The valve allows a maximum pressure of 3000 psi (210 bar) at port 3 and features an adjustable control option that permits up to a 22% variation from the nominal preset flow using an internal adjustment screw. Both priority and bypass flows are usable up to system operating pressures, maintaining relatively constant priority regardless of input variations. The sharp-edged orifice design minimizes viscosity-induced flow variations, while Sun's floating style construction reduces risks of internal part binding. It fits into cavity T19A, belongs to series 4, and has a capacity of up to 50 gpm (200 L/min). Its maximum operating pressure is rated at 5000 psi (350 bar), with an input flow capacity reaching up to 120 gpm (480 L/min). The valve's hex size measures 1-5/8 inches (41.3 mm), requiring installation torque between 350-375 lbf ft (475-508 Nm). The adjustment screw has an internal hex size of 5/32 inches (4 mm), while the locknut hex size is set at 9/16 inches (15 mm), with torque specifications ranging from 80-90 lbf in (9-10 Nm). Weighing approximately 2.70 lb (1.25 kg), this model includes a Viton seal kit for enhanced durability and performance in hydraulic systems.
Bypass/restrictive, fixed-orifice, priority flow controls take an input flow at port 1 and use it to satisfy the priority flow at port 3. If the input flow exceeds the priority flow requirement, the excess is bypassed out port 2. The bypass flow may be used in a secondary circuit.
- Customer must specify a flow rating. Factory set flow ratings are within +/- 10% of the requested setting.
- Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
- A tuneable adjustment control option provides up to +/- 22% variation from the nominal factory pre-set flow. Adjustment is done with +/- 3 turns of the adjust screw. Screw in (CW) to increase flow.
- Both priority and bypass flow are usable up to the system operating pressure.
- Priority remains relatively constant regardless of variation in input flow.
- Bypass flow is not available until priority flow requirements are satisfied.
- Pressure at the bypass port (port 2) may exceed pressure at the priority port (port 3).
- The sharp-edged orifice design minimizes flow variations due to viscosity changes.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-19A |
| Series | 4 |
| Capacity | 50 gpm200 L/min. |
| Maximum Operating Pressure | 5000 psi350 bar |
| Maximum Input Flow | 120 gpm480 L/min. |
| Valve Hex Size | 1 5/8 in.41,3 mm |
| Valve Installation Torque | 350 - 375 lbf ft475 - 508 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | 2.70 lb1,25 kg |
| Seal kit - Cartridge | Viton: 990-019-006 |
Show FAQ