***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics FRDDOAN (FRDDOAN) is a bypass-restrictive, fixed-orifice, priority flow control valve designed to manage hydraulic flow efficiently. This valve takes input flow at port 1 to fulfill the priority flow requirement at port 3, with any excess being diverted to port 2 for use in secondary circuits. It is engineered with enhanced damping compared to the FRDA model, addressing potential system instability issues. Users must specify a desired flow rating, which the factory sets within a 10% margin of the requested setting. The maximum pressure at port 3 should not exceed 3000 psi (210 bar), and both priority and bypass flows can operate up to the system's maximum pressure. The valve maintains consistent priority flow despite variations in input flow, while bypass flow activates only after meeting the priority requirement. The design features a sharp-edged orifice that reduces fluctuations due to viscosity changes and includes an adjustable control option allowing up to a 25% variation from the preset flow using a simple adjustment screw mechanism. The Sun floating style construction minimizes risks of internal binding due to excessive installation torque or machining inconsistencies. This model fits into cavity T-2A, belongs to series 2, and has a capacity of 12 gpm (45 L/min) with a maximum operating pressure of 5000 psi (350 bar). It accommodates an input flow of up to 30 gpm (120 L/min). Installation requires specific torque settings for both the valve and locknut components. Additionally, it supports Viton seal kits for maintenance purposes.
The Sun Hydraulics FRDDOAN (FRDDOAN) is a bypass-restrictive, fixed-orifice, priority flow control valve designed to manage hydraulic flow efficiently. This valve takes input flow at port 1 to fulfill the priority flow requirement at port 3, with any excess being diverted to port 2 for use in secondary circuits. It is engineered with enhanced damping compared to the FRDA model, addressing potential system instability issues. Users must specify a desired flow rating, which the factory sets within a 10% margin of the requested setting. The maximum pressure at port 3 should not exceed 3000 psi (210 bar), and both priority and bypass flows can operate up to the system's maximum pressure. The valve maintains consistent priority flow despite variations in input flow, while bypass flow activates only after meeting the priority requirement. The design features a sharp-edged orifice that reduces fluctuations due to viscosity changes and includes an adjustable control option allowing up to a 25% variation from the preset flow using a simple adjustment screw mechanism. The Sun floating style construction minimizes risks of internal binding due to excessive installation torque or machining inconsistencies. This model fits into cavity T-2A, belongs to series 2, and has a capacity of 12 gpm (45 L/min) with a maximum operating pressure of 5000 psi (350 bar). It accommodates an input flow of up to 30 gpm (120 L/min). Installation requires specific torque settings for both the valve and locknut components. Additionally, it supports Viton seal kits for maintenance purposes.
Bypass/restrictive, fixed-orifice, priority flow controls take an input flow at port 1 and use it to satisfy the priority flow at port 3. If the input flow exceeds the priority flow requirement, the excess is bypassed out port 2. The bypass flow may be used in a secondary circuit.
- This valve is more highly damped than the FRDA to help solve system instability problems.
- Customer must specify a flow rating. Factory set flow ratings are within +/- 10% of the requested setting.
- Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
- Both priority and bypass flow are usable up to the system operating pressure.
- Priority remains relatively constant regardless of variation in input flow.
- Bypass flow is not available until priority flow requirements are satisfied.
- Pressure at the bypass port (port 2) may exceed pressure at the priority port (port 3).
- The sharp-edged orifice design minimizes flow variations due to viscosity changes.
- A tuneable adjustment control option provides up to +/- 25% variation from the nominal factory pre-set flow. Adjustment is done with +/- 3 turns of the adjust screw. Screw in (CW) to increase flow.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-2A |
| Series | 2 |
| Capacity | 12 gpm45 L/min. |
| Maximum Operating Pressure | 5000 psi350 bar |
| Maximum Input Flow | 30 gpm120 L/min. |
| Valve Hex Size | 1 1/8 in.28,6 mm |
| Valve Installation Torque | 45 - 50 lbf ft61 - 68 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .40 lb0,20 kg |
| Seal kit - Cartridge | Viton: 990-202-006 |