SUN HYDRAULICS
FPHKXCV812N
$356.80 USD
Tags:
- SUN HYDRAULICS
- Material:FPHKXCV812N
- Model:FPHK-XCV@812N
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics FPHKXCV812N (FPHKXCV812N) is a pilot-operated, normally closed, electroproportional throttle valve with reverse free flow check capabilities. Designed to operate with pressures up to 5000 psi, this versatile valve is ideal for applications requiring precise control of hydraulic flow. When energized, the coil generates an opening force on the pilot stage that vents the main stage poppet, allowing for proportional opening and metered flow from port 1 to port 2. In reverse, it provides free flow from port 2 to port 1. The valve features interchangeable coils compatible with other Sun solenoid-operated valves and can be mounted on the tube in either direction. For optimal performance, it is recommended to use an amplifier with current sensing and adjustable dither between 100-250 Hz. The valve includes several manual override options, including a momentary-twist override that allows manual shifting by twisting clockwise 90 degrees. It incorporates Sun's floating style construction to minimize binding risks due to installation torque or machining variations. With a capacity of 60 gpm (240 L/min), it fits into a T16A cavity and requires a torque of 150-160 lbf ft (203-217 Nm) for installation. The model weighs 1.50 lb (0.70 kg) without the coil and increases to 2.00 lb with the coil attached. For sealing purposes, Viton seal kits are available for both the cartridge (990016006) and coil (990770006).
The Sun Hydraulics FPHKXCV812N (FPHKXCV812N) is a pilot-operated, normally closed, electroproportional throttle valve with reverse free flow check capabilities. Designed to operate with pressures up to 5000 psi, this versatile valve is ideal for applications requiring precise control of hydraulic flow. When energized, the coil generates an opening force on the pilot stage that vents the main stage poppet, allowing for proportional opening and metered flow from port 1 to port 2. In reverse, it provides free flow from port 2 to port 1. The valve features interchangeable coils compatible with other Sun solenoid-operated valves and can be mounted on the tube in either direction. For optimal performance, it is recommended to use an amplifier with current sensing and adjustable dither between 100-250 Hz. The valve includes several manual override options, including a momentary-twist override that allows manual shifting by twisting clockwise 90 degrees. It incorporates Sun's floating style construction to minimize binding risks due to installation torque or machining variations. With a capacity of 60 gpm (240 L/min), it fits into a T16A cavity and requires a torque of 150-160 lbf ft (203-217 Nm) for installation. The model weighs 1.50 lb (0.70 kg) without the coil and increases to 2.00 lb with the coil attached. For sealing purposes, Viton seal kits are available for both the cartridge (990016006) and coil (990770006).
This valve is a pilot operated, normally closed, electro-proportional throttle with reverse free flow check. Energizing the coil generates an opening force on the pilot stage which vents the main stage poppet to open proportionally. Metered flow is from port 1 to port 2 with reverse free flow from port 2 to port 1.
- Capable of operating with pressures up to 5000 psi.
- Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
- This cartridge has several manual override choices, including no manual override. See Option Configuration.
- For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
- The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
- Depending on circuit requirements, a reverse free flow check bypassing the compensator may be needed when using the FPHK with an external compensator.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-16A |
| Series | 3 |
| Capacity | 60 gpm240 L/min. |
| Recommended dither frequency | 100 Hz100 Hz |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 10 drops/min.@5000 psi0,7 cc/min.@350 bar |
| Manual Override Force Requirement | 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1 |
| Deadband, nominal (as a percentage of input) | 25%25% |
| Manual Override Stroke | .06 in.1,50 mm |
| Solenoid Tube Diameter | .75 in.19 mm |
| Valve Hex Size | 1 1/4 in.31,8 mm |
| Valve Installation Torque | 150 - 160 lbf ft203 - 217 Nm |
| Model Weight | 1.50 lb0,70 kg |
| Model Weight (with coil) | 2.00 lb2.00 lb |
| Seal kit - Cartridge | Viton: 990-016-006 |
| Seal and nut kit - Coil | Viton: 990-770-006Viton: 990-770-006 |
Show FAQ