SUN HYDRAULICS
FPHKXCN2F12V
$588.70 USD
Tags:
- SUN HYDRAULICS
- Material:FPHKXCN2F12V
- Model:FPHK-XCN@2F12V
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics FPHKXCN2F12V (Material Number: FPHKXCN2F12V) is a sophisticated pilot-operated, normally closed, electroproportional throttle valve with a reverse free flow check. This component is designed to handle pressures up to 5000 psi and is capable of metering flow from port 1 to port 2, while allowing reverse free flow from port 2 to port 1. It features interchangeable coils that can be mounted in either direction on the tube, providing flexibility in installation. The valve incorporates Sun's floating style construction, which reduces the risk of internal binding due to excessive torque or machining variations. For optimal performance, it is recommended to use an amplifier with current sensing and adjustable dither between 100-250 Hz. The valve offers several manual override options, including a momentary twist override that allows operation by twisting the override clockwise by 90 degrees. The FPHK model may require a reverse free flow check bypassing the compensator if used with an external compensator based on circuit requirements. The valve fits into a T16A cavity and belongs to Series 3 with a capacity of 60 gpm (240 L/min). It has a maximum leakage rate of 10 drops/min at 5000 psi and requires an override force of approximately 5 lbs/1000 psi at Port 1. The solenoid tube diameter measures .75 inches (19 mm), and the valve has a hex size of 1\u00bc inches (31.8 mm). Installation torque should be between 150-160 lbf.ft (203-217 Nm). The model weighs approximately 1.50 lbs without the coil and comes with Viton seal kits for both cartridge and coil applications for enhanced durability and sealing performance under various conditions.
The Sun Hydraulics FPHKXCN2F12V (Material Number: FPHKXCN2F12V) is a sophisticated pilot-operated, normally closed, electroproportional throttle valve with a reverse free flow check. This component is designed to handle pressures up to 5000 psi and is capable of metering flow from port 1 to port 2, while allowing reverse free flow from port 2 to port 1. It features interchangeable coils that can be mounted in either direction on the tube, providing flexibility in installation. The valve incorporates Sun's floating style construction, which reduces the risk of internal binding due to excessive torque or machining variations. For optimal performance, it is recommended to use an amplifier with current sensing and adjustable dither between 100-250 Hz. The valve offers several manual override options, including a momentary twist override that allows operation by twisting the override clockwise by 90 degrees. The FPHK model may require a reverse free flow check bypassing the compensator if used with an external compensator based on circuit requirements. The valve fits into a T16A cavity and belongs to Series 3 with a capacity of 60 gpm (240 L/min). It has a maximum leakage rate of 10 drops/min at 5000 psi and requires an override force of approximately 5 lbs/1000 psi at Port 1. The solenoid tube diameter measures .75 inches (19 mm), and the valve has a hex size of 1\u00bc inches (31.8 mm). Installation torque should be between 150-160 lbf.ft (203-217 Nm). The model weighs approximately 1.50 lbs without the coil and comes with Viton seal kits for both cartridge and coil applications for enhanced durability and sealing performance under various conditions.
This valve is a pilot operated, normally closed, electro-proportional throttle with reverse free flow check. Energizing the coil generates an opening force on the pilot stage which vents the main stage poppet to open proportionally. Metered flow is from port 1 to port 2 with reverse free flow from port 2 to port 1.
- Capable of operating with pressures up to 5000 psi.
- Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
- This cartridge has several manual override choices, including no manual override. See Option Configuration.
- For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
- The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
- Depending on circuit requirements, a reverse free flow check bypassing the compensator may be needed when using the FPHK with an external compensator.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-16A |
| Series | 3 |
| Capacity | 60 gpm240 L/min. |
| Recommended dither frequency | 100 Hz100 Hz |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 10 drops/min.@5000 psi0,7 cc/min.@350 bar |
| Manual Override Force Requirement | 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1 |
| Deadband, nominal (as a percentage of input) | 25%25% |
| Manual Override Stroke | .06 in.1,50 mm |
| Solenoid Tube Diameter | .75 in.19 mm |
| Valve Hex Size | 1 1/4 in.31,8 mm |
| Valve Installation Torque | 150 - 160 lbf ft203 - 217 Nm |
| Model Weight | 1.50 lb0,70 kg |
| Model Weight (with coil) | 2.00 lb2.00 lb |
| Seal kit - Cartridge | Viton: 990-016-006 |
| Seal and nut kit - Coil | Viton: 990-770-006Viton: 990-770-006 |
Show FAQ