SUN HYDRAULICS
FPHKMCV912
$367.20 USD
Tags:
- SUN HYDRAULICS
- Material:FPHKMCV912
- Model:FPHK-MCV@912
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics FPHKMCV912 (FPHKMCV912) is a pilot-operated, normally closed, electroproportional throttle valve with a reverse free flow check. Designed for high-pressure applications, it can operate up to 5000 psi. This valve allows metered flow from port 1 to port 2 and features reverse free flow from port 2 to port 1. The coil's energization creates an opening force on the pilot stage, venting the main stage poppet for proportional opening. It incorporates Sun's floating style construction, minimizing internal part binding due to excessive installation torque or machining variations. The valve has a capacity of 60 gpm (240 L/min) and fits into a T16A cavity with a series rating of 3. It offers various manual override options, including the momentary twist option E, which shifts the valve when twisted clockwise by 90 degrees. For optimal performance, it is recommended to use an amplifier with current sensing and adjustable dither between 100-250 Hz. The solenoid tube diameter is .75 inches (19 mm), and it requires an installation torque of 150-160 lbf ft (203-217 Nm). The valve's hex size is 1\u00bc inches (31.8 mm), and it weighs approximately 1.50 lbs without the coil and 2 lbs with the coil installed. The maximum leakage at 110 SUS (24 cSt) is limited to ten drops per minute at pressures up to 5000 psi (0.7 cc/min at 350 bar). Seal kits are available in Viton material for both cartridge and coil applications, ensuring durability in various operational environments.
The Sun Hydraulics FPHKMCV912 (FPHKMCV912) is a pilot-operated, normally closed, electroproportional throttle valve with a reverse free flow check. Designed for high-pressure applications, it can operate up to 5000 psi. This valve allows metered flow from port 1 to port 2 and features reverse free flow from port 2 to port 1. The coil's energization creates an opening force on the pilot stage, venting the main stage poppet for proportional opening. It incorporates Sun's floating style construction, minimizing internal part binding due to excessive installation torque or machining variations. The valve has a capacity of 60 gpm (240 L/min) and fits into a T16A cavity with a series rating of 3. It offers various manual override options, including the momentary twist option E, which shifts the valve when twisted clockwise by 90 degrees. For optimal performance, it is recommended to use an amplifier with current sensing and adjustable dither between 100-250 Hz. The solenoid tube diameter is .75 inches (19 mm), and it requires an installation torque of 150-160 lbf ft (203-217 Nm). The valve's hex size is 1\u00bc inches (31.8 mm), and it weighs approximately 1.50 lbs without the coil and 2 lbs with the coil installed. The maximum leakage at 110 SUS (24 cSt) is limited to ten drops per minute at pressures up to 5000 psi (0.7 cc/min at 350 bar). Seal kits are available in Viton material for both cartridge and coil applications, ensuring durability in various operational environments.
This valve is a pilot operated, normally closed, electro-proportional throttle with reverse free flow check. Energizing the coil generates an opening force on the pilot stage which vents the main stage poppet to open proportionally. Metered flow is from port 1 to port 2 with reverse free flow from port 2 to port 1.
- Capable of operating with pressures up to 5000 psi.
- Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
- This cartridge has several manual override choices, including no manual override. See Option Configuration.
- For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
- The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
- Depending on circuit requirements, a reverse free flow check bypassing the compensator may be needed when using the FPHK with an external compensator.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-16A |
| Series | 3 |
| Capacity | 60 gpm240 L/min. |
| Recommended dither frequency | 100 Hz100 Hz |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 10 drops/min.@5000 psi0,7 cc/min.@350 bar |
| Manual Override Force Requirement | 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1 |
| Deadband, nominal (as a percentage of input) | 25%25% |
| Manual Override Stroke | .06 in.1,50 mm |
| Solenoid Tube Diameter | .75 in.19 mm |
| Valve Hex Size | 1 1/4 in.31,8 mm |
| Valve Installation Torque | 150 - 160 lbf ft203 - 217 Nm |
| Model Weight | 1.50 lb0,70 kg |
| Model Weight (with coil) | 2.00 lb2.00 lb |
| Seal kit - Cartridge | Viton: 990-016-006 |
| Seal and nut kit - Coil | Viton: 990-770-006Viton: 990-770-006 |
Show FAQ