***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics FPHKMCN4F24V (FPHKMCN4F24V) is a pilot-operated, normally closed, electroproportional throttle valve with a reverse free flow check feature. This valve functions by energizing the coil to generate an opening force on the pilot stage, which then vents the main stage poppet to open proportionally. It facilitates metered flow from port 1 to port 2 and allows reverse free flow from port 2 to port 1. The valve can operate under pressures up to 5000 psi and is compatible with interchangeable coils from Sun's other full-flow solenoid-operated valves, which can be mounted in either direction on the tube. For optimal performance, it is recommended to use an amplifier with current sensing and adjustable dither, adjustable between 100-250 Hz. The valve offers several manual override options, including a momentary twist override option \"E,\" which enables the operator to shift the valve by twisting the manual override clockwise by 90 degrees. Depending on specific circuit requirements, a reverse free flow check bypassing the compensator might be necessary when using this model with an external compensator. The FPHKMCN4F24V incorporates Sun's floating style construction to reduce internal parts binding due to excessive installation torque or cavity/cartridge machining variations. It fits into a T16A cavity and belongs to Series 3 with a capacity of 60 gpm (240 L/min). The maximum valve leakage at 110 SUS (24 cSt) is approximately 10 drops/min at 5000 psi (0.7 cc/min at 350 bar). The manual override requires a force of about 5 lbs/1000 psi at Port 1 (33 N/100 bar). The solenoid tube diameter measures .75 inches (19 mm), and it has a hex size of 1-1/4 inches (31.8 mm), requiring an installation torque between 150-160 lbf-ft (203-217 Nm).
The Sun Hydraulics FPHKMCN4F24V (FPHKMCN4F24V) is a pilot-operated, normally closed, electroproportional throttle valve with a reverse free flow check feature. This valve functions by energizing the coil to generate an opening force on the pilot stage, which then vents the main stage poppet to open proportionally. It facilitates metered flow from port 1 to port 2 and allows reverse free flow from port 2 to port 1. The valve can operate under pressures up to 5000 psi and is compatible with interchangeable coils from Sun's other full-flow solenoid-operated valves, which can be mounted in either direction on the tube. For optimal performance, it is recommended to use an amplifier with current sensing and adjustable dither, adjustable between 100-250 Hz. The valve offers several manual override options, including a momentary twist override option \"E,\" which enables the operator to shift the valve by twisting the manual override clockwise by 90 degrees. Depending on specific circuit requirements, a reverse free flow check bypassing the compensator might be necessary when using this model with an external compensator. The FPHKMCN4F24V incorporates Sun's floating style construction to reduce internal parts binding due to excessive installation torque or cavity/cartridge machining variations. It fits into a T16A cavity and belongs to Series 3 with a capacity of 60 gpm (240 L/min). The maximum valve leakage at 110 SUS (24 cSt) is approximately 10 drops/min at 5000 psi (0.7 cc/min at 350 bar). The manual override requires a force of about 5 lbs/1000 psi at Port 1 (33 N/100 bar). The solenoid tube diameter measures .75 inches (19 mm), and it has a hex size of 1-1/4 inches (31.8 mm), requiring an installation torque between 150-160 lbf-ft (203-217 Nm).
This valve is a pilot operated, normally closed, electro-proportional throttle with reverse free flow check. Energizing the coil generates an opening force on the pilot stage which vents the main stage poppet to open proportionally. Metered flow is from port 1 to port 2 with reverse free flow from port 2 to port 1.
- Capable of operating with pressures up to 5000 psi.
- Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
- This cartridge has several manual override choices, including no manual override. See Option Configuration.
- For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
- The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
- Depending on circuit requirements, a reverse free flow check bypassing the compensator may be needed when using the FPHK with an external compensator.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-16A |
| Series | 3 |
| Capacity | 60 gpm240 L/min. |
| Recommended dither frequency | 100 Hz100 Hz |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 10 drops/min.@5000 psi0,7 cc/min.@350 bar |
| Manual Override Force Requirement | 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1 |
| Deadband, nominal (as a percentage of input) | 25%25% |
| Manual Override Stroke | .06 in.1,50 mm |
| Solenoid Tube Diameter | .75 in.19 mm |
| Valve Hex Size | 1 1/4 in.31,8 mm |
| Valve Installation Torque | 150 - 160 lbf ft203 - 217 Nm |
| Model Weight | 1.50 lb0,70 kg |
| Model Weight (with coil) | 2.00 lb2.00 lb |
| Seal kit - Cartridge | Viton: 990-016-006 |
| Seal and nut kit - Coil | Viton: 990-770-006Viton: 990-770-006 |