Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics FPHKEEN224 (FPHKEEN224) is a pilot-operated, normally closed, electroproportional throttle valve featuring a reverse free flow check. This sophisticated valve is designed to function by energizing the coil, which generates an opening force on the pilot stage, thereby venting the main stage poppet to open proportionally. It offers metered flow from port 1 to port 2 and reverse free flow from port 2 to port 1. The valve is capable of operating under pressures up to 5000 psi and has a capacity of handling flow rates up to 60 gpm (240 L/min). The FPHKEEN224 incorporates interchangeable coils with other full-flow solenoid-operated valves from Sun Hydraulics and can be mounted in either direction on the tube. For optimal performance, it is recommended to use an amplifier with current sensing and adjustable dither between 100-250 Hz. The valve also includes several manual override options, such as the momentary-twist override (option E), which allows for manual shifting by twisting the override clockwise by 90 degrees. With its floating style construction, this cartridge minimizes potential binding of internal parts due to excessive installation torque or machining variations in the cavity/cartridge. It fits into a T16A cavity and requires an installation torque of 150-160 lbf ft (203-217 Nm). The valve's deadband is nominally set at 25% of input, and it has a maximum leakage rate of 10 drops/min at 5000 psi (0.7 cc/min at 350 bar). Additionally, it weighs approximately 1.50 lb without the coil and around 2.00 lb with it installed.
The Sun Hydraulics FPHKEEN224 (FPHKEEN224) is a pilot-operated, normally closed, electroproportional throttle valve featuring a reverse free flow check. This sophisticated valve is designed to function by energizing the coil, which generates an opening force on the pilot stage, thereby venting the main stage poppet to open proportionally. It offers metered flow from port 1 to port 2 and reverse free flow from port 2 to port 1. The valve is capable of operating under pressures up to 5000 psi and has a capacity of handling flow rates up to 60 gpm (240 L/min). The FPHKEEN224 incorporates interchangeable coils with other full-flow solenoid-operated valves from Sun Hydraulics and can be mounted in either direction on the tube. For optimal performance, it is recommended to use an amplifier with current sensing and adjustable dither between 100-250 Hz. The valve also includes several manual override options, such as the momentary-twist override (option E), which allows for manual shifting by twisting the override clockwise by 90 degrees. With its floating style construction, this cartridge minimizes potential binding of internal parts due to excessive installation torque or machining variations in the cavity/cartridge. It fits into a T16A cavity and requires an installation torque of 150-160 lbf ft (203-217 Nm). The valve's deadband is nominally set at 25% of input, and it has a maximum leakage rate of 10 drops/min at 5000 psi (0.7 cc/min at 350 bar). Additionally, it weighs approximately 1.50 lb without the coil and around 2.00 lb with it installed.
This valve is a pilot operated, normally closed, electro-proportional throttle with reverse free flow check. Energizing the coil generates an opening force on the pilot stage which vents the main stage poppet to open proportionally. Metered flow is from port 1 to port 2 with reverse free flow from port 2 to port 1.
- Capable of operating with pressures up to 5000 psi.
- Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
- This cartridge has several manual override choices, including no manual override. See Option Configuration.
- For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
- The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
- Depending on circuit requirements, a reverse free flow check bypassing the compensator may be needed when using the FPHK with an external compensator.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-16A |
| Series | 3 |
| Capacity | 60 gpm240 L/min. |
| Recommended dither frequency | 100 Hz100 Hz |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 10 drops/min.@5000 psi0,7 cc/min.@350 bar |
| Manual Override Force Requirement | 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1 |
| Deadband, nominal (as a percentage of input) | 25%25% |
| Manual Override Stroke | .06 in.1,50 mm |
| Solenoid Tube Diameter | .75 in.19 mm |
| Valve Hex Size | 1 1/4 in.31,8 mm |
| Valve Installation Torque | 150 - 160 lbf ft203 - 217 Nm |
| Model Weight | 1.50 lb0,70 kg |
| Model Weight (with coil) | 2.00 lb2.00 lb |
| Seal kit - Cartridge | Viton: 990-016-006 |
| Seal and nut kit - Coil | Viton: 990-770-006Viton: 990-770-006 |
Show FAQ