***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics FPHKECV2D24A (FPHKECV2D24A) is a pilot-operated, normally closed, electroproportional throttle valve featuring a reverse free flow check. It is designed to handle pressures up to 5000 psi and provides metered flow from port 1 to port 2, with reverse free flow from port 2 to port 1. This valve incorporates Sun's floating style construction, minimizing the risk of internal parts binding due to excessive installation torque or machining variations. The FPHKECV2D24A is compatible with interchangeable coils that can be mounted in either direction on the solenoid tube. For optimal performance, it is recommended to use an amplifier with current sensing and adjustable dither between 100-250 Hz. The valve offers several manual override options, including a momentary-twist override that allows operation by twisting the manual control clockwise by 90 degrees. It fits into a T16A cavity and belongs to Series 3, offering a capacity of up to 60 gpm (240 L/min). The valve features a nominal deadband percentage of input at 25% and has a maximum leakage rate of 10 drops/min at 5000 psi (0.7 cc/min at 350 bar). Installation requires a torque setting between 150-160 lbf ft (203-217 Nm), and the model weighs approximately 1.50 lb without the coil and around 2.00 lb with it installed. Seal kits for both the cartridge and coil are available in Viton material under part numbers Viton:990016006 and Viton:990770006 respectively.
The Sun Hydraulics FPHKECV2D24A (FPHKECV2D24A) is a pilot-operated, normally closed, electroproportional throttle valve featuring a reverse free flow check. It is designed to handle pressures up to 5000 psi and provides metered flow from port 1 to port 2, with reverse free flow from port 2 to port 1. This valve incorporates Sun's floating style construction, minimizing the risk of internal parts binding due to excessive installation torque or machining variations. The FPHKECV2D24A is compatible with interchangeable coils that can be mounted in either direction on the solenoid tube. For optimal performance, it is recommended to use an amplifier with current sensing and adjustable dither between 100-250 Hz. The valve offers several manual override options, including a momentary-twist override that allows operation by twisting the manual control clockwise by 90 degrees. It fits into a T16A cavity and belongs to Series 3, offering a capacity of up to 60 gpm (240 L/min). The valve features a nominal deadband percentage of input at 25% and has a maximum leakage rate of 10 drops/min at 5000 psi (0.7 cc/min at 350 bar). Installation requires a torque setting between 150-160 lbf ft (203-217 Nm), and the model weighs approximately 1.50 lb without the coil and around 2.00 lb with it installed. Seal kits for both the cartridge and coil are available in Viton material under part numbers Viton:990016006 and Viton:990770006 respectively.
This valve is a pilot operated, normally closed, electro-proportional throttle with reverse free flow check. Energizing the coil generates an opening force on the pilot stage which vents the main stage poppet to open proportionally. Metered flow is from port 1 to port 2 with reverse free flow from port 2 to port 1.
- Capable of operating with pressures up to 5000 psi.
- Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
- This cartridge has several manual override choices, including no manual override. See Option Configuration.
- For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
- The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
- Depending on circuit requirements, a reverse free flow check bypassing the compensator may be needed when using the FPHK with an external compensator.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-16A |
| Series | 3 |
| Capacity | 60 gpm240 L/min. |
| Recommended dither frequency | 100 Hz100 Hz |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 10 drops/min.@5000 psi0,7 cc/min.@350 bar |
| Manual Override Force Requirement | 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1 |
| Deadband, nominal (as a percentage of input) | 25%25% |
| Manual Override Stroke | .06 in.1,50 mm |
| Solenoid Tube Diameter | .75 in.19 mm |
| Valve Hex Size | 1 1/4 in.31,8 mm |
| Valve Installation Torque | 150 - 160 lbf ft203 - 217 Nm |
| Model Weight | 1.50 lb0,70 kg |
| Model Weight (with coil) | 2.00 lb2.00 lb |
| Seal kit - Cartridge | Viton: 990-016-006 |
| Seal and nut kit - Coil | Viton: 990-770-006Viton: 990-770-006 |