SUN HYDRAULICS
FMDAEDV824
$338.10 USD
Tags:
- SUN HYDRAULICS
- Material:FMDAEDV824
- Model:FMDA-EDV@824
- Summary:Cartridge
Quantity in stock: 0
The Sun Hydraulics FMDAEDV824 (FMDAEDV824) is a 3-way, meter-in, electro-proportional throttle valve designed for precise flow control in hydraulic systems. In its unenergized state, the valve blocks supply at port 1 and drains port 2 to tank at port 3. When the coil is energized, it creates a closing force on the spool, forming a metering orifice between ports 1 and 2 that adjusts proportionally to the coil command current. This self-compensating feature allows for pressure-compensated flow control when used with an external compensator. The valve's flow capacity from port 2 to port 3 is approximately 1.5 gpm (6 L/min), optimized for increased resolution and capacity rather than proportional control. The FMDAEDV824 is suitable for circuits with a separate passage to tank, such as cushion lock circuits. Utilizing two of these valves can create a meter-in/meter-out configuration in a three-position, four-way circuit. The transition between positions remains closed, and using two three-ways to form a four-way allows for selection from existing flow ranges without requiring custom spools. For enhanced accuracy in flow control over various flows and pressures, an external modulating logic element can be added for further compensation. All ports are rated to accept pressures up to 5000 psi (350 bar). The valve features interchangeable coils with Sun's other solenoid-operated valves and supports both directions of mounting on the tube. Additional specifications include a cavity size of T-11A, series number 1, and a maximum capacity of 9 gpm (34 L/min). The manual override requires approximately five pounds of force per 1000 psi at Port 1 and has an approximate mechanical life expectancy of around 7,000 cycles. For optimal performance, it's recommended to use an amplifier with current sensing and adjustable dither between 100-250 Hz.
This valve is a 3-way, meter-in, electro-proportional throttle. The flow path, unenergized, has the supply blocked at port 1 and port 2 is drained to tank at port 3. Energizing the coil generates a closing force on the spool, creating a metering orifice in the 1 to 2 direction that is proportional to the coil command current. The valve self-compensates in the 1 to 2 direction and with the addition of an external compensator will provide pressure compensated flow control.
Flow in the 2 to 3 direction is not proportional and is limited in the interest of increased resolution and capacity. Flow capacity in the 2 to 3 direction is about 1.5 gpm (6 L/min). This valve is meant to be used in a circuit that has a separate passage to tank such as a cushion lock circuit. Two FMDA's in conjunction with a cushion lock circuit create a meter-in/meter-out 3 position 4-way.
- Note: Flow in the 2 to 3 direction is limited to about 1.5 gpm (5 L/pm).
- The transition between positions is closed.
- Using 2 3-ways to create a 4-way allows one to choose existing flow ranges instead of cutting a special spool.
- These valves may be pressure compensated by an external, modulating, logic element. Use LR_C-XHN for a bypass circuit or LP_C-XHN for a restrictive circuit.
- The valve provides a degree of self-compensation and may be used as a flow control. To increase the accuracy of flow control, an external, modulating, logic element can be used to maintain a constant flow over a wider range of flows and pressures. See performance curves for additional information.
- All ports will accept 5000 psi (350 bar).
- On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, E, L and T manual control assemblies have a mechanical life expectancy of approximately 7,000 cycles.
- The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
- Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
- For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-11A |
| Series | 1 |
| Capacity | 9 gpm34 L/min. |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 2 in³/min.@1000 psi30 cc/min.@70 bar |
| Manual Override Force Requirement | 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1 |
| Manual Override Stroke | .10 in.2,5 mm |
| Solenoid Tube Diameter | .75 in.19 mm |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Model Weight (with coil) | 1.10 lb0,50 kg |
| Seal kit - Cartridge | Viton: 990-411-006 |
| Seal and nut kit - Coil | Viton: 990-770-006Viton: 990-770-006 |
Show FAQ