***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CKGCEEN (CKGCEEN) is a pilot-to-open check valve designed for hydraulic systems requiring reliable load holding and hose break protection. This valve features a sealed pilot to prevent cross-port leakage, making it ideal for applications where such leakage is undesirable. It supports free flow from port 2 to the load port 1 and blocks flow in the reverse direction, ensuring that loads are held securely and do not drift. The Delrin seat within the valve is particularly suited for medium pressure systems that may contain some level of contamination; it provides durable performance even in environments not characterized by high flows or temperatures. The CKGCEEN offers an optional external porting configuration which blocks port 3 for external piloting, enhancing its versatility in system integration. The valve's design incorporates Sun's floating style construction which minimizes potential binding of internal parts due to variations in installation torque or cavity/cartridge machining. This feature helps maintain smooth operation and prolongs the valve\u2019s lifespan. With a maximum operating pressure of 2500 psi (175 bar) and a capacity of up to 60 gpm (240 L/min), this valve is capable of handling significant hydraulic loads efficiently. The pilot ratio of 3:1 ensures that the pilot pressure needed at port 3 to open the valve is directly proportional to the load pressure at port 1, with pressure at port 2 opposing this pilot pressure directly. Designed for easy maintenance, if there are signs of load drift due to seat damage from contamination, replacement is straightforward. In addition, manual load release control options provide further operational flexibility, allowing users to manually release loads when necessary by turning the load release clockwise. Overall, the Sun Hydraulics CKGCEEN check valve offers robust performance and reliability for hydraulic systems requiring precise control over load holding and directional flow security.

This valve is a pilot to open check valve. It has a sealed pilot, a Delrin seat, and is non-vented. It allows free flow from the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3) will open the valve from port 1 to port 2. Pilot pressure needed at port 3 to open the valve is directly proportional to the load pressure at port 1. Pressure at port 2 directly opposes pilot pressure.

  • This 3 port pilot-to-open check valve and 3 port counterbalance valves are physically interchangeable (i.e. same cavities, same flow path for a given frame size). However, cartridge extension dimensions from the mounting surface may vary.
  • Provides hose break protection, prevents loads from drifting and positively locks pressurized loads.
  • Sealed pilot for use in circuits where cross port leakage is undesirable.
  • Optional external porting out of the hex end of the cartridge is available for external piloting. In this configuration, port 3 is blocked. See Control options E, and P.
  • The Delrin seat is suitable for dirty, medium pressure systems that are not subjected to high flows or temperatures.
  • Extremely low leakage. If the load drifts due to the valve, the seat has probably been damaged by contamination and the valve should be replaced.
  • For models with manual load release control option, turn load release clockwise to release load.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-17A
Series 3
Capacity 60 gpm240 L/min.
Pilot Ratio 3:13:1
Maximum Operating Pressure 2500 psi175 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 1 drops/min.0,07 cc/min.
Valve Hex Size 1 1/4 in.31,8 mm
Valve Installation Torque 150 - 160 lbf ft203 - 217 Nm
Model Weight 1.10 lb0,50 kg
Seal kit - Cartridge Viton: 990-017-006