***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CKEVSCV (CKEVSCV) is a high-performance pilot-to-open check valve designed for hydraulic applications requiring reliable load holding and hose break protection. This valve facilitates free flow from port 2 to load port 1 while blocking flow in the opposite direction. It operates with a pilot pressure that is proportional to the load pressure at port 1, requiring a minimum of 75 psi over vent pressure to prevent closure. The valve features a sealed pilot to avoid cross-port leakage and incorporates Sun's floating style construction, which minimizes internal part binding due to installation torque or cavity/cartridge machining variations. The CKEVSCV is built with a steel seat for durability and has extremely low leakage characteristics, with only about one drop of fluid loss per 4000 cycles from the pilot area to the vented spring chamber. It has a maximum operating pressure of 5000 psi and can handle up to 30 gpm flow capacity. The valve's design includes atmospherically referenced venting, which can be susceptible to external leakage and moisture ingress into the spring chamber over time; thus, four-port vented designs are recommended for new applications. This model also provides options for manual load release control, enhancing its utility in various hydraulic systems. The CKEVSCV is ideal for applications where hose break protection and positive locking of pressurized loads are critical. Its robust construction ensures long life and reliability even under demanding conditions, making it an essential component for efficient hydraulic operations.

This valve is a pilot to open check valve. It has a sealed pilot, a steel seat, and is vented. It allows free flow from the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3) pilot port will open the valve from port 1 to port 2. Pilot pressure needed to open the valve is directly proportional to the load pressure at port 1. The valve is insensitive to pressure at port 2 because the spring chamber is referenced out the back of the hex body.

  • There is a positve seal between ports 2 and 3.
  • Pilot pressure as low as 75 psi (5 bar) higher than the pressure at the vent can prevent the valve from closing.
  • Atmospherically referenced pilot-to-open check valves are considered problem solvers for existing circuits using non-vented valves. However, the atmospherically referenced valve will eventually leak externally or allow moisture into the spring chamber. Four-port vented pilot-to-open check cartridges are recommended for new applications.
  • Pilot-to-open check cartridges are locking valves, not motion control valves. For motion control applications, use counterbalance valves.
  • Approximately 1 drop (0,07 cc) of fluid will pass from the pilot area to the vented spring chamber every 4000 cycles.
  • For models with manual load release control option, turn load release clockwise to release load.
  • Provides hose break protection, prevents loads from drifting and positively locks pressurized loads.
  • Extremely low leakage. The seat and poppet are heat treated for long life. If the load drifts due to the valve, the seat has probably been damaged by contamination and the valve should be replaced.
  • Sealed pilot for use in circuits where cross port leakage is undesirable.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-2A
Series 2
Capacity 30 gpm120 L/min.
Pilot Ratio 3:13:1
Maximum Operating Pressure 5000 psi350 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 1 drops/min.0,07 cc/min.
Valve Hex Size 1 1/8 in.28,6 mm
Valve Installation Torque 45 - 50 lbf ft61 - 68 Nm
Model Weight .50 lb0,25 kg
Seal kit - Cartridge Viton: 990-202-006