You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
CKEAKCN


$138.60 USD

Tags:

  • SUN HYDRAULICS
  • Material:CKEAKCN
  • Model:CKEA-KCN
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CKEAKCN (CKEAKCN) is a pilot-to-open check valve designed for hydraulic systems, featuring a non-sealed pilot with a Delrin seat and non-vented design. This valve allows free flow from valve port 2 to load port 1 while blocking flow in the opposite direction. The operation of the valve is controlled by pressure at the pilot port 3, which opens the valve to allow flow from port 1 to port 2. The required pilot pressure at port 3 is directly proportional to the load pressure at port 1, with backpressure at port 2 opposing this pilot pressure. The CKEAKCN model has a maximum operating pressure of 2500 psi (175 bar) and a flow capacity of up to 30 gpm (120 L/min). It features extremely low leakage characteristics, crucial for applications requiring robust load holding capabilities such as hose break protection and prevention of load drift. The standard unsealed pilot facilitates air purging in the circuit, enhancing operational reliability. Optional external piloting can be configured by blocking port 3 and using external ports out of the hex end of the cartridge. This model's Delrin seat makes it suitable for medium-pressure systems that are not exposed to high flows or temperatures, providing durability in environments with moderate contamination levels. Furthermore, Sun Hydraulics incorporates floating style construction in this model to minimize potential issues due to excessive installation torque or variations in cavity/cartridge machining. For manual load release control models, turning the load release clockwise releases the held load. The pilot ratio stands at an effective range between 3:1 and 4.4:1 depending on specific operating conditions, ensuring flexible application across different system pressures. Overall, Sun Hydraulics' CKEAKCN offers reliable performance for hydraulic systems requiring precise backflow prevention and load control functionalities.

This valve is a pilot to open check valve. It has a non-sealed pilot, a Delrin seat, and is non-vented. It allows free flow from the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3) will open the valve, allowing flow from port 1 to port 2. Pilot pressure needed at port 3 to open the valve is directly proportional to the load pressure at port 1. Pressure at port 2 directly opposes pilot pressure.

  • This 3 port pilot-to-open check valve and 3 port counterbalance valves are physically interchangeable (i.e. same cavities, same flow path for a given frame size). However, cartridge extension dimensions from the mounting surface may vary.
  • Provides hose break protection, prevents loads from drifting and positively locks pressurized loads.
  • Standard unsealed pilot allows air trapped in the pilot line to be purged from the circuit.
  • Optional external porting out of the hex end of the cartridge is available for external piloting. In this configuration, port 3 is blocked. See Control options E, and P.
  • Pilot-to-open check cartridges are locking valves, not motion control valves. For motion control applications, use counterbalance valves.
  • The Delrin seat is suitable for dirty, medium pressure systems that are not subjected to high flows or temperatures.
  • Extremely low leakage. If the load drifts due to the valve, the seat has probably been damaged by contamination and the valve should be replaced.
  • For models with manual load release control option, turn load release clockwise to release load.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-2A
Series 2
Capacity 30 gpm120 L/min.
Pilot Ratio 3:13:1
Maximum Operating Pressure 2500 psi175 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 1 drops/min.0,07 cc/min.
Valve Hex Size 1 1/8 in.28,6 mm
Valve Installation Torque 45 - 50 lbf ft61 - 68 Nm
Model Weight .50 lb0,25 kg
Seal kit - Cartridge Viton: 990-202-006

Show FAQ