***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CBCARHV (CBCARHV) is a meticulously engineered counterbalance valve designed to manage and control overrunning loads effectively in hydraulic systems. This valve incorporates a check valve that permits free flow from port 2 to the load at port 1, while a pilot-assisted relief valve manages the flow from port 1 back to port 2. The pilot assist feature at port 3 enhances the functionality by reducing the relief valve setting based on the pilot ratio, which is crucial for applications requiring precise motion control. The CBCARHV model is equipped with settings that should be adjusted to at least 1.3 times the maximum load-induced pressure to ensure optimal performance. It allows for manual adjustments where turning the adjustment screw clockwise decreases the setting, thereby releasing the load with a minimum setting of less than 200 psi (14 bar). Additionally, backpressure at port 2 influences the effective relief setting, adding complexity and precision in handling loads. The design of this model includes Sun's floating style construction which minimizes internal parts binding - a common issue caused by excessive installation torque or variations in cavity/cartridge machining. Furthermore, it offers two check valve cracking pressures catering to different operational needs; typically, a 25 psi check is used unless actuator cavitation concerns dictate otherwise. This counterbalance valve also features interchangeable cartridges within the same frame size for various configurations like load control and pilot-to-open check cartridges. Notably, it lacks positive seals in the pilot section which may allow passage between ports under certain conditions – an aspect significant in master-slave circuits or when conducting leak tests on valve/cylinder assemblies. Sun Hydraulics has designed this model allowing direct installation into machined actuator housings enhancing protection and circuit stiffness. With its robust construction and versatile applications, CBCARHV serves as an essential component for effective hydraulic system management across various equipment setups.

Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio.

Other names for this valve include motion control valve and over center valve.

  • Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
  • Turn adjustment clockwise to decrease setting and release load.
  • Full clockwise setting is less than 200 psi (14 bar).
  • Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure.
  • Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
  • Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
  • Two check valve cracking pressures are available. Use the 25 psi (1,7 bar) check unless actuator cavitation is a concern.
  • All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
  • This valve does not have positive seals on the pilot section and will pass up to 3 in³/min.@1000 psi (45 ml/min.@70 bar ) between port 2 and port 3. This is a consideration in master-slave circuits and in the leak testing of valve-cylinder assemblies.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-11A
Series 1
Capacity 15 gpm60 L/min.
Pilot Ratio 3:13:1
Maximum Recommended Load Pressure at Maximum Setting 3075 psi215 bar
Maximum Setting 4000 psi280 bar
Factory Pressure Settings Established at 2 in³/min.30 cc/min.
Maximum Valve Leakage at Reseat 5 drops/min.0,3 cc/min.
Adjustment - Number of Counterclockwise Turns to Increase Setting 3.753.75
Operating Characteristic StandardStandard
Reseat >85% of setting>85% of setting
Valve Hex Size 7/8 in.22,2 mm
Valve Installation Torque 30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size 5/32 in.4 mm
Locknut Hex Size 9/16 in.15 mm
Locknut Torque 80 - 90 lbf in.9 - 10 Nm
Model Weight .40 lb0,20 kg
Seal kit - Cartridge Viton: 990-011-006