SUN HYDRAULICS
CAIGCGV
$591.40 USD
Tags:
- SUN HYDRAULICS
- Material:CAIGCGV
- Model:CAIG-CGV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CAIGCGV (CAIGCGV) is an atmospherically vented counterbalance valve with pilot assist, designed to control overrunning loads effectively. This valve features a check valve that permits free flow from the directional valve port to the load port while a direct-acting, pilot-assisted relief valve manages flow from port to port. The pilot assist at a specific port reduces the effective setting of the relief valve based on the pilot ratio. Importantly, backpressure at another specified port does not influence the valve setting due to the spring chamber being atmospherically referenced. This model is engineered to be set at least 1.3 times the maximum load-induced pressure and can be adjusted by turning clockwise to decrease settings and release loads. The full clockwise setting provides a maximum of 5000 psi (345 bar). Designed for durability and reliability, it incorporates Sun's floating style construction which minimizes potential internal parts binding due to installation torque or variations in cavity/cartridge machining. The CAIGCGV offers high versatility as it can be directly installed into cavities machined into actuator housings, enhancing protection and circuit stiffness. It ensures positive seals between all ports and requires a lower pilot ratio for achieving machine stability compared to non-vented valves. All port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable for a given frame size within this series. Key specifications include a capacity of 40 gpm (151 L/min), a standard pilot ratio of 3:1, and factory pressure settings established at 25 in³/min (410 cc/min). The maximum recommended load pressure at maximum setting is 5000 psi (345 bar), with an adjustment feature allowing numerous counterclockwise turns to increase the setting. This model also boasts minimal leakage at reseat, less than 5 drops/min., ensuring efficient operation even under demanding conditions.
The Sun Hydraulics CAIGCGV (CAIGCGV) is an atmospherically vented counterbalance valve with pilot assist, designed to control overrunning loads effectively. This valve features a check valve that permits free flow from the directional valve port to the load port while a direct-acting, pilot-assisted relief valve manages flow from port to port. The pilot assist at a specific port reduces the effective setting of the relief valve based on the pilot ratio. Importantly, backpressure at another specified port does not influence the valve setting due to the spring chamber being atmospherically referenced. This model is engineered to be set at least 1.3 times the maximum load-induced pressure and can be adjusted by turning clockwise to decrease settings and release loads. The full clockwise setting provides a maximum of 5000 psi (345 bar). Designed for durability and reliability, it incorporates Sun's floating style construction which minimizes potential internal parts binding due to installation torque or variations in cavity/cartridge machining. The CAIGCGV offers high versatility as it can be directly installed into cavities machined into actuator housings, enhancing protection and circuit stiffness. It ensures positive seals between all ports and requires a lower pilot ratio for achieving machine stability compared to non-vented valves. All port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable for a given frame size within this series. Key specifications include a capacity of 40 gpm (151 L/min), a standard pilot ratio of 3:1, and factory pressure settings established at 25 in³/min (410 cc/min). The maximum recommended load pressure at maximum setting is 5000 psi (345 bar), with an adjustment feature allowing numerous counterclockwise turns to increase the setting. This model also boasts minimal leakage at reseat, less than 5 drops/min., ensuring efficient operation even under demanding conditions.
Atmospherically-vented counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamber is atmospherically referenced.
Other names for this valve include motion control valve and over center valve.
- Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
- Turn adjustment clockwise to decrease setting and release load.
- Full clockwise setting is 200 psi (14 bar).
- Approximately 1 drop (0,07 cc) of fluid will pass from the pilot area to the vented spring chamber every 4000 cycles.
- Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
- Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
- This valve has positive seals between all ports.
- With vented valves, a lower pilot ratio may be required to achieve machine stability compared to non-vented valves.
- All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-19A |
| Series | 4 |
| Capacity | 120 gpm480 L/min. |
| Pilot Ratio | 5:15:1 |
| Maximum Recommended Load Pressure at Maximum Setting | 4615 psi320 bar |
| Maximum Setting | 6000 psi420 bar |
| Factory Pressure Settings Established at | 2 in³/min.30 cc/min. |
| Maximum Valve Leakage at Reseat | 5 drops/min.0,3 cc/min. |
| Check Cracking Pressure | 20 psi1,5 bar |
| Adjustment - Number of Counterclockwise Turns to Increase Setting | 55 |
| Operating Characteristic | StandardStandard |
| Reseat | >85% of setting>85% of setting |
| Valve Hex Size | 1 5/8 in.41,3 mm |
| Valve Installation Torque | 350 - 375 lbf ft475 - 508 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Seal kit - Cartridge | Viton: 990-119-006 |
Show FAQ