SUN HYDRAULICS
CAIACHN
$580.10 USD
Tags:
- SUN HYDRAULICS
- Material:CAIACHN
- Model:CAIA-CHN
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CAIACHN (CAIACHN) is an atmospherically vented counterbalance valve with pilot assist, designed to manage overrunning loads effectively. This valve incorporates a check valve that permits free flow from the directional valve port to the load port. Additionally, it features a direct-acting, pilot-assisted relief valve that controls flow from port to port. The pilot assist at the specified port significantly reduces the effective setting of the relief valve based on the pilot ratio. The CAIACHN model is engineered to maintain stability and performance in hydraulic systems by ensuring that backpressure at a specific port does not influence the valve setting due to its atmospheric referencing in the spring chamber. This model is beneficial for applications requiring precise control over load handling and movement, providing enhanced protection against mechanical shock and system variations. The design specifications include a maximum setting of 5000 psi (344.7 bar) with factory pressure settings established at certain flow rates. The valve also features a check cracking pressure set at 25 psi (1.7 bar), ensuring reliable operation under varied conditions. For maintenance and adjustments, this model allows for manual tuning through its adjustment feature, which can be turned clockwise or counterclockwise to modify the setting as needed. The construction includes Sun’s floating style which minimizes internal part binding due to installation torque or cavity-cartridge machining discrepancies. Overall, the Sun Hydraulics CAIACHN counterbalance valve is an essential component for hydraulic circuits requiring robust control and reliability in managing dynamic loads efficiently while preventing external leakage and moisture ingress into the spring chamber over time.
The Sun Hydraulics CAIACHN (CAIACHN) is an atmospherically vented counterbalance valve with pilot assist, designed to manage overrunning loads effectively. This valve incorporates a check valve that permits free flow from the directional valve port to the load port. Additionally, it features a direct-acting, pilot-assisted relief valve that controls flow from port to port. The pilot assist at the specified port significantly reduces the effective setting of the relief valve based on the pilot ratio. The CAIACHN model is engineered to maintain stability and performance in hydraulic systems by ensuring that backpressure at a specific port does not influence the valve setting due to its atmospheric referencing in the spring chamber. This model is beneficial for applications requiring precise control over load handling and movement, providing enhanced protection against mechanical shock and system variations. The design specifications include a maximum setting of 5000 psi (344.7 bar) with factory pressure settings established at certain flow rates. The valve also features a check cracking pressure set at 25 psi (1.7 bar), ensuring reliable operation under varied conditions. For maintenance and adjustments, this model allows for manual tuning through its adjustment feature, which can be turned clockwise or counterclockwise to modify the setting as needed. The construction includes Sun’s floating style which minimizes internal part binding due to installation torque or cavity-cartridge machining discrepancies. Overall, the Sun Hydraulics CAIACHN counterbalance valve is an essential component for hydraulic circuits requiring robust control and reliability in managing dynamic loads efficiently while preventing external leakage and moisture ingress into the spring chamber over time.
Atmospherically-vented counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamber is atmospherically referenced.
Other names for this valve include motion control valve and over center valve.
- Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
- Turn adjustment clockwise to decrease setting and release load.
- Full clockwise setting is 200 psi (14 bar).
- Approximately 1 drop (0,07 cc) of fluid will pass from the pilot area to the vented spring chamber every 4000 cycles.
- Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
- Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
- This valve has positive seals between all ports.
- With vented valves, a lower pilot ratio may be required to achieve machine stability compared to non-vented valves.
- Three-port vented valves are atmospherically referenced and considered problem solvers for existing circuits using non-vented valves. Over time, the vented valves may leak externally or allow moisture into the spring chamber. Four-port vented counterbalance valves are recommended for new applications.
- All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-19A |
| Series | 4 |
| Capacity | 120 gpm480 L/min. |
| Pilot Ratio | 3:13:1 |
| Maximum Recommended Load Pressure at Maximum Setting | 3075 psi215 bar |
| Maximum Setting | 4000 psi280 bar |
| Factory Pressure Settings Established at | 2 in³/min.30 cc/min. |
| Maximum Valve Leakage at Reseat | 5 drops/min.0,3 cc/min. |
| Check Cracking Pressure | 20 psi1,5 bar |
| Adjustment - Number of Counterclockwise Turns to Increase Setting | 55 |
| Operating Characteristic | StandardStandard |
| Reseat | >85% of setting>85% of setting |
| Valve Hex Size | 1 5/8 in.41,3 mm |
| Valve Installation Torque | 350 - 375 lbf ft475 - 508 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | 3.00 lb1,35 kg |
| Seal kit - Cartridge | Viton: 990-119-006 |
Show FAQ