SUN HYDRAULICS
XQIFLANBX
$1,543.60 USD
Tags:
- SUN HYDRAULICS
- Material:XQIFLANBX
- Model:XQIF-LAN-BX
- Summary:Y-assembly
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQIFLANBX (Material Number: XQIFLANBX) is a sophisticated valve assembly designed to efficiently charge an accumulator using a fixed displacement pump. This assembly is engineered to unload the pump when the pressure reaches a predetermined set point and to bring the pump back online when pressure drops according to the pilot valve's fixed percentage. It features a ventable relief that functions both as a main stage for unloading the pump and as an overpressure relief system, with an additional circuit that softens the pump's unloading process. For optimal operation, it requires a separate drain line to mitigate erratic behavior due to tank line pressure fluctuations. When configuring this assembly, selecting an appropriate adjustment range is crucial, as system pressure drops and flow rates can influence the unloading valves' performance. The design ensures that low operating pressures with narrow differentials necessitate precise system design, while high flow rates may result in significant pressure drops affecting differential management. The pressure settings relate specifically to port 1 of the QPA pilot valve, with variations in pump and accumulator pressures due to flow-induced drops. The assembly's large porting relative to its capacity encourages using large piping to minimize flow-induced pressure issues. The spool design of the pilot valve maintains a consistent differential ratio through non-wearing spool diameters. It's essential that the accumulator pilot valve is set below any system reliefs on the pump side to prevent excessive heating. The included relief acts as an overpressure safeguard, preset higher than any pilot valve settings and capped for security. With a capacity of 80 gpm (320 L/min), this line-mount body type assembly requires specific mounting hole specifications for proper installation and operation.
The Sun Hydraulics XQIFLANBX (Material Number: XQIFLANBX) is a sophisticated valve assembly designed to efficiently charge an accumulator using a fixed displacement pump. This assembly is engineered to unload the pump when the pressure reaches a predetermined set point and to bring the pump back online when pressure drops according to the pilot valve's fixed percentage. It features a ventable relief that functions both as a main stage for unloading the pump and as an overpressure relief system, with an additional circuit that softens the pump's unloading process. For optimal operation, it requires a separate drain line to mitigate erratic behavior due to tank line pressure fluctuations. When configuring this assembly, selecting an appropriate adjustment range is crucial, as system pressure drops and flow rates can influence the unloading valves' performance. The design ensures that low operating pressures with narrow differentials necessitate precise system design, while high flow rates may result in significant pressure drops affecting differential management. The pressure settings relate specifically to port 1 of the QPA pilot valve, with variations in pump and accumulator pressures due to flow-induced drops. The assembly's large porting relative to its capacity encourages using large piping to minimize flow-induced pressure issues. The spool design of the pilot valve maintains a consistent differential ratio through non-wearing spool diameters. It's essential that the accumulator pilot valve is set below any system reliefs on the pump side to prevent excessive heating. The included relief acts as an overpressure safeguard, preset higher than any pilot valve settings and capped for security. With a capacity of 80 gpm (320 L/min), this line-mount body type assembly requires specific mounting hole specifications for proper installation and operation.
This valve assembly is meant to charge an accumulator using a fixed displacement pump. When the pressure reaches the set point of the valve, the pump is unloaded. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the pump is brought back on line to recharge the accumulator. The ventable relief serves a dual purpose as a main stage to unload the pump and as a system over-pressure relief. The assembly has an additional feature; a simple circuit that softens the unloading of the pump.
- When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
- NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
- The pressure setting and the resultant reseat pressure are in reference to the port 1 area of the QPA* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow.
- The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
- The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
- The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
- The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.
| Capacity | 80 gpm320 L/min. |
| Body Type | Line mountLine mount |
| Mounting Hole Thread | .375-16 UNC - 2B in..375-16 UNC - 2B in. |
| Mounting Hole Depth | .88 in.22,4 mm |
| Mounting Hole Quantity | 33 |
Show FAQ
Additional Resources
- Integrated Packages: Solutions That Grow Your Reputation
- Fluid and Temperature Recommendations
- Sun's Floating Style Screw-In Cartridge
- Sun Model Code Explanation; 999-901-334
- Custom Integrated Packages from Sun
Notes:
- Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.