***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PPHBCQN (PPHBCQN) is a pilot-operated pressure reducing/relieving valve designed to manage high primary pressures at the inlet port and maintain a consistent reduced pressure at port 1, with a full-flow relief function from port 1 to tank port 3. This valve is adept at handling pressures up to 5000 psi (350 bar) and is characterized by its exceptionally stable performance with low hysteresis. It features a flat pressure-flow characteristic making it suitable for applications where precise pressure control is essential. The valve's construction incorporates Sun's floating style, minimizing internal part binding due to excessive installation torque or machining variations. It supports flow capacities up to 40 gpm (160 L/min), with adjustable pressure settings controlled through a series of clockwise turns. This model can be configured with EPDM seals for systems using phosphate ester fluids, although exposure to petroleum-based fluids should be avoided to prevent seal damage. The PPHBCQN valve is interchangeable within its series for different mounting configurations, often requiring a full-capacity return line at port 3 when used in reducing/relieving applications. For circuits needing reverse free flow from reduced pressure port 1 to inlet port 2, additional check valves are recommended as the main spool may close under such conditions. The valve's design allows for easy adjustment across its full range when no special setting is specified, ensuring flexibility in various hydraulic systems.

Pilot-operated, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3).

  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-17A
Series3
Capacity40 gpm160 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow15 - 20 in³/min.0,25 - 0,33 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/4 in.31,8 mm
Valve Installation Torque150 - 160 lbf ft203 - 217 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight1.30 lb0,60 kg
Seal kit - CartridgeViton: 990-017-006

Show FAQ

Additional Resources



Notes:
  • Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) N and Q are 2000 psi (140 bar) W is 5000 psi (350 bar)inlet pressure