SUN HYDRAULICS
PPDBQAN
$86.70 USD
Tags:
- SUN HYDRAULICS
- Material:PPDBQAN
- Model:PPDB-QAN
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PPDBQAN (PPDBQAN) is a pilot-operated, pressure-reducing/relieving valve designed to reduce high primary pressure at inlet port 2 to a consistent reduced pressure at port 1, while providing a full-flow relief function from port 1 to tank port 3. This valve is part of Sun Hydraulics' three-port pressure reducing and reducing/relieving cartridges, which are interchangeable in terms of flow path and cavity size for a given frame size. It is recommended to use a full-capacity return line for mounting configurations involving reducing/relieving cartridges. The valve is capable of full reverse flow from reduced pressure port 1 to inlet port 2, although this may close the main spool; hence, adding a separate check valve is advised if reverse free flow is required. This model exhibits stable performance with low hysteresis and exceptionally flat pressure-flow characteristics. It operates with maximum inlet pressures determined by the adjustment range: Ranges D, E, N, and Q allow for up to 2000 psi (140 bar) differential between inlet and reduced pressures; Ranges A, B, and H allow up to 3000 psi (210 bar); Ranges C and W can handle up to 5000 psi (350 bar) inlet pressure. The valve setting at port 3 should not exceed 5000 psi (350 bar). Notably, this pilot-operated model is not fast-acting; users needing superior dynamic response should consider direct-acting alternatives. The PPDBQAN incorporates Sun's floating style construction to minimize internal binding risks due to installation torque or machining variations. It comes equipped with EPDM seals suitable for phosphate ester fluids but incompatible with petroleum-based substances. The cartridge has a capacity of 10 gpm (40 L/min), operates under a maximum pressure of 5000 psi (350 bar), and requires specific installation torques detailed in its specifications.
The Sun Hydraulics PPDBQAN (PPDBQAN) is a pilot-operated, pressure-reducing/relieving valve designed to reduce high primary pressure at inlet port 2 to a consistent reduced pressure at port 1, while providing a full-flow relief function from port 1 to tank port 3. This valve is part of Sun Hydraulics' three-port pressure reducing and reducing/relieving cartridges, which are interchangeable in terms of flow path and cavity size for a given frame size. It is recommended to use a full-capacity return line for mounting configurations involving reducing/relieving cartridges. The valve is capable of full reverse flow from reduced pressure port 1 to inlet port 2, although this may close the main spool; hence, adding a separate check valve is advised if reverse free flow is required. This model exhibits stable performance with low hysteresis and exceptionally flat pressure-flow characteristics. It operates with maximum inlet pressures determined by the adjustment range: Ranges D, E, N, and Q allow for up to 2000 psi (140 bar) differential between inlet and reduced pressures; Ranges A, B, and H allow up to 3000 psi (210 bar); Ranges C and W can handle up to 5000 psi (350 bar) inlet pressure. The valve setting at port 3 should not exceed 5000 psi (350 bar). Notably, this pilot-operated model is not fast-acting; users needing superior dynamic response should consider direct-acting alternatives. The PPDBQAN incorporates Sun's floating style construction to minimize internal binding risks due to installation torque or machining variations. It comes equipped with EPDM seals suitable for phosphate ester fluids but incompatible with petroleum-based substances. The cartridge has a capacity of 10 gpm (40 L/min), operates under a maximum pressure of 5000 psi (350 bar), and requires specific installation torques detailed in its specifications.
Pilot-operated, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3).
- All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
- Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
- Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
- W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
- Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
Cavity | T-11A |
Series | 1 |
Capacity | 10 gpm40 L/min. |
Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
Maximum Operating Pressure | 5000 psi350 bar |
Control Pilot Flow | 7 - 10 in³/min.0,11 - 0,16 L/min. |
Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
Valve Hex Size | 7/8 in.22,2 mm |
Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
Locknut Hex Size | 9/16 in.15 mm |
Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
Model Weight | .30 lb0,15 kg |
Seal kit - Cartridge | Viton: 990-011-006 |
Show FAQ
Additional Resources
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Sun Expands Corrosion-Resistant Solutions
- Manufacturing Sun Cartridge Cavities
- Reducing and Reducing/Relieving Valves
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
- Cartridges: Materials of Construction
- Fluid and Temperature Recommendations
Notes:
- Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) N and Q are 2000 psi (140 bar) W is 5000 psi (350 bar)inlet pressure
- For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.