SUN HYDRAULICS
FPHKECN2D24A
$706.60 USD
Tags:
- SUN HYDRAULICS
- Material:FPHKECN2D24A
- Model:FPHK-ECN@2D24A
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics FPHKECN2D24A (Material Number: FPHKECN2D24A) is a sophisticated pilot-operated, normally closed, electroproportional throttle valve equipped with a reverse free flow check. Upon energizing the coil, the valve generates an opening force on the pilot stage, venting the main stage poppet to open proportionally. This results in metered flow from port 1 to port 2, while allowing reverse free flow from port 2 to port 1. This valve is engineered to operate under pressures up to 5000 psi and has a capacity of handling up to 60 gpm (240 L/min). It features interchangeable coils that can be mounted in either direction and offers several manual override options, including a momentary-twist override option that enables shifting by twisting clockwise by 90 degrees. For optimal performance, it is recommended to use an amplifier with current sensing and adjustable dither between 100-250 Hz. The Sun floating style construction minimizes potential binding of internal parts due to excessive installation torque or cavity-cartridge machining variations. The valve's design incorporates a T16A cavity and belongs to Series 3. It also includes specifications such as a solenoid tube diameter of .75 inches (19 mm) and requires an installation torque between 150-160 lbf ft (203-217 Nm). The model weighs approximately 1.50 lb without the coil and around 2.00 lb with it installed. For maintenance or replacement needs, Viton seal kits are available for both the cartridge and coil components.
The Sun Hydraulics FPHKECN2D24A (Material Number: FPHKECN2D24A) is a sophisticated pilot-operated, normally closed, electroproportional throttle valve equipped with a reverse free flow check. Upon energizing the coil, the valve generates an opening force on the pilot stage, venting the main stage poppet to open proportionally. This results in metered flow from port 1 to port 2, while allowing reverse free flow from port 2 to port 1. This valve is engineered to operate under pressures up to 5000 psi and has a capacity of handling up to 60 gpm (240 L/min). It features interchangeable coils that can be mounted in either direction and offers several manual override options, including a momentary-twist override option that enables shifting by twisting clockwise by 90 degrees. For optimal performance, it is recommended to use an amplifier with current sensing and adjustable dither between 100-250 Hz. The Sun floating style construction minimizes potential binding of internal parts due to excessive installation torque or cavity-cartridge machining variations. The valve's design incorporates a T16A cavity and belongs to Series 3. It also includes specifications such as a solenoid tube diameter of .75 inches (19 mm) and requires an installation torque between 150-160 lbf ft (203-217 Nm). The model weighs approximately 1.50 lb without the coil and around 2.00 lb with it installed. For maintenance or replacement needs, Viton seal kits are available for both the cartridge and coil components.
This valve is a pilot operated, normally closed, electro-proportional throttle with reverse free flow check. Energizing the coil generates an opening force on the pilot stage which vents the main stage poppet to open proportionally. Metered flow is from port 1 to port 2 with reverse free flow from port 2 to port 1.
- Capable of operating with pressures up to 5000 psi.
- Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
- This cartridge has several manual override choices, including no manual override. See Option Configuration.
- For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
- The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
- Depending on circuit requirements, a reverse free flow check bypassing the compensator may be needed when using the FPHK with an external compensator.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
Cavity | T-16A |
Series | 3 |
Capacity | 60 gpm240 L/min. |
Recommended dither frequency | 100 Hz100 Hz |
Maximum Valve Leakage at 110 SUS (24 cSt) | 10 drops/min.@5000 psi0,7 cc/min.@350 bar |
Manual Override Force Requirement | 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1 |
Deadband, nominal (as a percentage of input) | 25%25% |
Manual Override Stroke | .06 in.1,50 mm |
Solenoid Tube Diameter | .75 in.19 mm |
Valve Hex Size | 1 1/4 in.31,8 mm |
Valve Installation Torque | 150 - 160 lbf ft203 - 217 Nm |
Model Weight | 1.50 lb0,70 kg |
Model Weight (with coil) | 2.00 lb2.00 lb |
Seal kit - Cartridge | Viton: 990-016-006 |
Seal and nut kit - Coil | Viton: 990-770-006Viton: 990-770-006 |
Show FAQ