You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
FMDAEDV912


$293.40 USD

Tags:

  • SUN HYDRAULICS
  • Material:FMDAEDV912
  • Model:FMDA-EDV@912
  • Summary:Cartridge

Quantity in stock: 0

***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics FMDAEDV912 (FMDAEDV912) is a sophisticated 3-way, meter-in, electro-proportional throttle valve designed for precise flow control applications. In its unenergized state, the supply is blocked at port 1 while port 2 drains to tank at port 3. When the coil is energized, it exerts a closing force on the spool, creating a metering orifice in the 1 to 2 direction that adjusts proportionally to the coil command current. This valve is self-compensating in the 1 to 2 direction and can be pressure-compensated with an external compensator for enhanced flow control accuracy. The FMDAEDV912 limits flow in the 2 to 3 direction to approximately 1.5 gpm (6 L/min) for increased resolution and capacity. It is ideally used in circuits with separate passages to tank, such as cushion lock circuits, and can be combined with another FMDA valve to form a meter-in-meter-out configuration for more complex hydraulic systems. The valve features a closed transition between positions and allows users to select existing flow ranges without requiring custom spools. It supports pressure compensation via an external modulating logic element and offers self-compensation capabilities for basic flow control functions. For optimal performance, employing an amplifier with current sensing and adjustable dither (100-250 Hz) is recommended. The FMDAEDV912 integrates Sun's floating style construction to minimize internal binding risks due to installation torque or machining variations. This model fits into T-11A cavities and operates efficiently at pressures up to 5000 psi (350 bar). Its manual override mechanism provides temporary actuation with a life expectancy of about 7,000 cycles. Coils are interchangeable with other Sun solenoid-operated valves, enhancing versatility across hydraulic systems requiring precise electro-proportional control solutions.

This valve is a 3-way, meter-in, electro-proportional throttle. The flow path, unenergized, has the supply blocked at port 1 and port 2 is drained to tank at port 3. Energizing the coil generates a closing force on the spool, creating a metering orifice in the 1 to 2 direction that is proportional to the coil command current. The valve self-compensates in the 1 to 2 direction and with the addition of an external compensator will provide pressure compensated flow control.

Flow in the 2 to 3 direction is not proportional and is limited in the interest of increased resolution and capacity. Flow capacity in the 2 to 3 direction is about 1.5 gpm (6 L/min). This valve is meant to be used in a circuit that has a separate passage to tank such as a cushion lock circuit. Two FMDA's in conjunction with a cushion lock circuit create a meter-in/meter-out 3 position 4-way.

  • Note: Flow in the 2 to 3 direction is limited to about 1.5 gpm (5 L/pm).
  • The transition between positions is closed.
  • Using 2 3-ways to create a 4-way allows one to choose existing flow ranges instead of cutting a special spool.
  • These valves may be pressure compensated by an external, modulating, logic element. Use LR_C-XHN for a bypass circuit or LP_C-XHN for a restrictive circuit.
  • The valve provides a degree of self-compensation and may be used as a flow control. To increase the accuracy of flow control, an external, modulating, logic element can be used to maintain a constant flow over a wider range of flows and pressures. See performance curves for additional information.
  • All ports will accept 5000 psi (350 bar).
  • On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, E, L and T manual control assemblies have a mechanical life expectancy of approximately 7,000 cycles.
  • The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
  • Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
  • For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-11A
Series 1
Capacity 9 gpm34 L/min.
Maximum Valve Leakage at 110 SUS (24 cSt) 2 in³/min.@1000 psi30 cc/min.@70 bar
Manual Override Force Requirement 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1
Manual Override Stroke .10 in.2,5 mm
Solenoid Tube Diameter .75 in.19 mm
Valve Hex Size 7/8 in.22,2 mm
Valve Installation Torque 30 - 35 lbf ft41 - 47 Nm
Model Weight (with coil) 1.10 lb0,50 kg
Seal kit - Cartridge Viton: 990-411-006
Seal and nut kit - Coil Viton: 990-770-006Viton: 990-770-006

Show FAQ