HYDAC
3353201
$10,611.16 USD
- HYDAC
- Material:3353201
- Model:CONTAMINATION SENSOR
- Summary:FCU 1310-4-U-AS-1
Quantity in stock: 0
The FCU 1000 is a portable service unit for the temporary measurement of particulate contamination, water saturation and fluid temperature in hydraulic systems. The integrated pump and the hoses included in the scope of delivery of the FCU 1000 series enable application on:
- control circuits
- pressure circuits and
- depressurised containers
All measurement data (ISO, SAE/NAS and % saturation and temperature in °C or °F) are stored in files (measurement value file) and folders (measurement points) in the internal data memory. The data memory takes place with a time stamp. The evaluation can then be readily carried out on the PC in MS Excel or in HYDAC's own FluidMonitoring software (FluMoS). For application in hydraulic systems, for the Service Department in the mobile hydraulics and for maintenance.
- Operating mode: short-term operation (S4, in accordance with DIN EN 60034/VDE 0530)
- Cleanliness classes in accordance with ISO and SAE and/or NAS:
Measurement range calibrated: ISO 13/11/10 ... ISO 23/21/18
Measurement range display: ISO Code 9/8/7 (MIN) to ISO Code 25/24/23 (MAX) - Integrated AquaSensor AS 1000 for the measurement of moisture and temperature: saturation level: 0 ... 100%; Temperature: -25 ... 100°C
- suitable for hydraulic oils up to 350 mm2/s (hydraulic oils up to ISO VG 68)