BOSCH REXROTH
R911173742
$1,253.63 USD
- BOSCH REXROTH
- Material:R911173742
- Model:S20-DO-64/1
Quantity in stock: 0
The Bosch Rexroth S20-DO-64/1 (R911173742) is a state-of-the-art digital output module designed to seamlessly integrate into cabinet IO systems. This module is specifically engineered for use within an S20 station, offering a robust and compact design that maximizes flexibility and cost-effectiveness in custom machine concepts. The S20-DO-64/1 features 64 digital outputs with a voltage of 24 VDC and a current capacity of 0.5A per channel, making it ideal for connecting actuators using 2-wire connection technology. The device boasts a forced ventilated axial fan, ensuring reliable operation through effective cooling. Its quick reaction time and ease of installation are notable, as it can be mounted on top hat rails within control cabinets or directly in the field. The S20-DO-64/1’s mechanics are durable, accommodating the demanding environments often found in industrial settings. Moreover, this module supports open communication standards, which allows for perfect integration and high availability within various systems. It also features innovative assembly and installation concepts that save space without compromising performance or functionality. With individually combinable modules, users benefit from the product's modular nature, allowing for tailored configurations to meet specific requirements. The S20-DO-64/1 comes equipped with diagnostic and status indicators that provide real-time feedback on system performance and facilitate troubleshooting. Additionally, the outputs of this module are safeguarded against short circuits and overloads, enhancing its reliability and longevity. The saved device nameplate feature simplifies maintenance and management tasks by allowing easy identification of the module within complex systems. Overall, the Bosch Rexroth S20-DO-64/1 is an advanced solution designed to deliver efficient digital signal output capabilities in various industrial applications where precision and durability are paramount.
Cabinet I/O S20
The modular, compact device design of the I/O systems from Rexroth provides you with maximum flexibility for cost-effective implementation of your custom machine concepts. The I/O modules have a robust design and mechanics, Forced ventilated - Axial fan 230Vre easy to handle, have a fast reaction time and are quick to install – both in the control cabinet as well as in the field. Open communication standards allow you to perfectly integrate the I/O modules with maximum availability.
Unpacked Weight: 0.301 kg
This module is designed for use within an S20 station. It is used to output digital signals. The outputs are protected against short circuits and overload.
| Innovative assembly and installation concept |
| Individually combinable modules |
| Space-saving I/O technology for top hat rail mounting |
| Compact, modular and simple |
| 2D CAD | Download 2D CAD |
| 3D CAD | Download 3D CAD |
| Type code extension | S20-DO-64/1 |
| Productgroup ID | 4,6 |
| ctrlX configurator | https://www.boschrexroth.com/ctrlx-configurator/ |
| Number of channels | 64 |
| EPLAN | https://ecad-configuration.boschrexroth.com/?rootpartnr=BOS.S20-DO-64%2F1**&downloads=true |
| Weight | 0.301 |
General data
|
Type |
S20-DO-64/1 | |
|
Color |
Gray | |
|
Weight 1) |
g |
260 |
|
Ambient temperature (operation) |
-25 °C ... +60 °C | |
|
Ambient temperature (storage/transport) |
-40 °C ... +85 °C | |
|
Permissible relative humidity (operation) |
5 % ... 95 %, no dewing | |
|
Permissible relative humidity (storage/transport) |
5 % ... 95 %, no dewing | |
|
Air pressure (operation) |
70 kPa ... 106 kPa (up to 3000 m above sea level) | |
|
Air pressure (storage/transport) |
70 kPa ... 106 kPa (up to 3000 m above sea level) | |
|
Protection type |
IP20 | |
|
Protection class |
III, IEC 61140, EN 61140, VDE 0140-1 | |
|
Installation position |
Any (no temperature derating) | |
| 1) | Including plug and bus base module |
Connection data
|
Type |
S20-DO-64/1 | |
|
Designation |
S20 connector | |
|
Connection type |
Push-in technology | |
|
Conductor cross-section solid/flexible/AWG |
0.2 mm² ... 1.5 mm² 0.2 mm² ... 1.5 mm² 24 ... 16 |
|
|
Stripping length |
mm |
8 |
Interface local bus
|
Type |
S20-DO-64/1 | |
|
Connection type |
Bus base module | |
|
Transmission speed |
MBit/s |
100 |
Power supply to logic
|
Type |
S20-DO-64/1 | |
|
Logic voltage UBus 1) |
V DC |
5 |
|
Maximum current consumption from UBus |
mA |
120 |
|
Maximum power consumption from UBus |
mW |
600 |
| 1) | Via bus base module |
Power supply to peripherals
|
Type |
S20-DO-64/1 | |
|
Feed to digital output modules UO |
V DC |
24 |
|
Maximum permitted voltage range 1) |
19.2 V DC ... 30 V DC | |
|
Current consumption from UO 2) |
A |
≤ 16 |
|
Typical power consumption from UO 3) |
W |
1.2 |
|
Maximum power consumption from UO 4) |
W |
480 |
|
Overvoltage/reverse polarity protection supply voltage |
Electronic (35 V, 0.5 s) / parallel diode; with external security 5 A (only for commissioning) | |
|
Guarantee 5) |
A |
≤ 16 |
| 1) | Including all tolerances, including ripple |
| 2) | For parallel power supply, secure externally |
| 3) | Without actuators |
| 4) | Of which 1.8 W internal losses |
| 5) | Reverse polarity protection up to 5 A |
Digital outputs
|
Type |
S20-DO-64/1 | |||
|
Number of digital outputs |
64 | |||
|
Connection type |
Push-in technology | |||
|
Connectivity technology |
1-wire | |||
|
Nominal output voltage |
24 V DC | |||
|
Output current per channel |
mA |
≤ 500 | ||
|
Output current per device 1) |
A |
≤ 16 | ||
|
Nominal load |
Ohmic |
48 Ω; for nominal voltage |
W |
≤ 12 |
|
Lamps |
for nominal voltage |
W |
≤ 12 | |
|
Inductance |
1.2 H, 48 Ω; for nominal voltage |
VA |
≤ 12 | |
|
Signal delay upon activation |
µs |
≤ 100 | ||
|
Signal delay upon deactivation |
µs |
≤ 100 | ||
|
Switching frequency |
Max. 10000 per second (for ohmic nominal load) Max. 1 per second (for inductive nominal load) Max. 16 per second (for lamp nominal load) |
|||
|
Load |
kΩ |
≥ 10 | ||
|
Energy consumption |
See diagram | |||
|
Limited inductive cut-off voltage |
-25.8 V ... -15 V | |||
|
Output voltage in deactivated state |
V |
≤ 1 | ||
|
Output current in deactivated state |
μA |
≤ 300 | ||
|
Behavior |
For overload |
Shutdown with automatic restart | ||
|
For inductive overload |
Output can be destroyed | |||
|
Reverse voltage protection from short pulses |
Limited reverse voltage protection up to 0.5 A for 1 s | |||
|
Overcurrent cutoff |
A |
> 0.7 | ||
|
Output current upon overvoltage in deactivated state |
mA |
< 1 | ||
|
Short-circuit protection, overload protection of the outputs |
Electronic | |||
| 1) | Secure externally |
PROFIBUS telegram data
|
Type |
S20-DO-64/1 | |
|
Need for parameter data |
byte |
1 |
|
Need for configuration data |
byte |
6 |
Error messages to the higher-level control or computer system
|
Type |
S20-DO-64/1 | |
|
Error message |
Short-circuit/overload of digital outputs | |
Electrical isolation/insulation of the voltage ranges
|
Type |
S20-DO-64/1 | |
|
Test distance |
Test voltage | |
|
5 V supply (logic)/24 V supply (peripherals) |
500 V AC, 50 Hz, 1 min. | |
|
5 V supply (logic)/function earth |
500 V AC, 50 Hz, 1 min. | |
|
24 V supply (peripherals)/function earth |
500 V AC, 50 Hz, 1 min. | |
Mechanical tests
|
Type |
S20-DO-64/1 | |
|
Vibration resistance 1) |
g |
5 |
|
Shock 2) |
g |
30 |
|
Continuous shock 2) |
g |
10 |
| 1) | Acc. to EN 60068-2-6/IEC 60068-2-6 |
| 2) | Acc. to EN 60068-2-27/IEC 60068-2-27 |
Conformity
|
Type |
S20-DO-64/1 | ||
|
Conforms with |
|||
|
Testing of interference immunity acc. to EN 61000-6-2 |
Discharge of static electricity (ESD) |
Criterion B; 6 kV contact discharge; 8 kV air discharge acc. to EN 61000-4-2/IEC 61000-4-2 | |
|
Electro-magnetic fields |
Criterion A; field strength: 10 V/m acc. to EN 61000-4-3/IEC 61000-4-3 | ||
|
Fast transients (burst) |
Criterion B; 2 kV acc. to EN 61000-4-4/IEC 61000-4-4 | ||
|
Transient overvoltage (surge) |
Criterion B; supply lines DC: ±0.5 kV/±0.5 kV (symmetric/asymmetric) acc. to EN 61000-4-5/IEC 61000-4-5 | ||
|
Line-fed disturbances |
Criterion A; test voltage 10 V acc. to EN 61000-4-6/IEC 61000-4-6 | ||
|
Testing of disturbance transmission acc. to EN 61000-6-3 |
Radio disturbance characteristics |
Class B acc. to EN 55022 | |
|
Approvals |
|
The current approvals can be found at www.boschrexroth.com. |
Dimensions
|
Type |
S20-DO-64/1 | |
|
A |
mm |
53.6 |
|
B |
mm |
129.9 |
|
C |
mm |
54 |
|
Note on dimensions |
The depth applies when using a support rail TH 35-7.5 (acc. to EN 60715). | |