The Bosch Rexroth S67-S3-BK-DI8-M8 (R911172899) is a fieldbus coupler designed to seamlessly integrate S IO modules with a Sercos III network. This unit features 8 digital inputs, enabling it to handle multiple signals and facilitate efficient data communication within automated systems. It is engineered to support a considerable number of modules on the local system bus, enhancing its scalability and flexibility for various application requirements. The S67-S3-BK-DI8-M8 ensures reliable connectivity within an automation setup, maintaining a maximum distance of 10 meters between any two modules. This capability is critical in distributed control systems where components are spread across different locations. Moreover, it allows for a total extension of up to 50 meters per station, providing ample coverage for extensive industrial environments. Its robust design and adherence to industry standards make it suitable for a broad range of applications that require precise and secure communication between control systems and peripheral devices.
This fieldbus coupler is used to connect the S67 I/O modules to Sercos III. It comes with 8 digital inputs. It supports up to 64 modules on the local system bus. The maximum distance between two modules is 50 meters, with a maximum total extension of 500 meters per station.
General data
|
Type |
S67-S3-BK-DI8-M8 | |
|
Weight |
g |
≈ 360 |
|
Ambient temperature (operation) |
-25 °C ... +60 °C | |
|
Permissible relative humidity (operation) |
5 % ... 95 %, no dewing | |
|
Air pressure (operation) |
795 ... 1080 hPa | |
|
Protection type |
IP67 | |
Interface fieldbus
|
Type |
S67-S3-BK-DI8-M8 | |
|
Fieldbus system |
Sercos | |
|
Connection type |
M12 connector, shielded, B-coded, 5-pin | |
|
Transmission speed 1) |
100 MBit/s | |
|
Transfer physics |
Copper cable (Cat-5e, Class D) - - - |
|
| 1) | Full-duplex |
Interface local bus
|
Type |
S67-S3-BK-DI8-M8 | |
|
Designation |
System bus | |
|
Connection type |
M12 connector, shielded, B-coded, 5-pin | |
|
Transfer physics |
Copper cable (Cat-5e, Class D) | |
System boundaries
|
Type |
S67-S3-BK-DI8-M8 | |
|
Number of supported participants per station 1) |
≤ 63 | |
| 1) | I/O modules |
Supply of module electronics
|
Type |
S67-S3-BK-DI8-M8 | |
|
Connection type |
A-coded 4-pin M12 plug | |
|
Current carrying capacity of supply connections 1) |
A |
≤ 8 |
|
Voltage supply logic and sensors ULS |
V DC |
24 |
|
Voltage supply actuators UA |
V DC |
24 |
|
Current consumption from ULS |
Typ. 45 mA + sensors (max. 400 mA) | |
|
Current consumption from UA |
mA |
5 |
|
Reverse polarity protection |
For ULS + UA | |
|
Short-circuit protection of the sensor supply |
Yes | |
| 1) | (ULS: 4 A, UA: 4 A) |
Digital inputs
|
Type |
S67-S3-BK-DI8-M8 | |
|
Number of digital inputs |
8 | |
|
Connection type |
A-coded 3-pin M8 plug | |
|
Connectivity technology |
2-, 3-wire technology | |
|
Dimensioning of inputs |
Acc. to EN 61131-2 type 1 | |
|
Input voltage range |
24 V DC (-30 V DC < UIN < +30 V DC) | |
|
Nominal input voltage UINenn |
V DC |
24 |
|
Nominal input current at UINenn |
mA |
2.8 |
|
Input voltage range "0" signal |
-30 V ... +5 V | |
|
Input voltage range "1" signal |
+15 V ... +30 V | |
|
Input filter time |
≤ 10 μs | |
Mechanical tests
|
Type |
S67-S3-BK-DI8-M8 | |
|
Vibration resistance |
Acc. to IEC 60068-2-6 | |
|
Shock |
Acc. to IEC 60068-2-27 | |
|
Approvals |
|
The current approvals can be found at www.boschrexroth.com. |
Dimensions
|
Type |
S67-S3-BK-DI8-M8 | |
|
A |
mm |
75 |
|
B |
mm |
117 |
|
C1 |
mm |
10.7 |
|
C2 |
mm |
25 |