BOSCH REXROTH
R911172576
$1,502.65 USD
- BOSCH REXROTH
- Material:R911172576
- Model:R-IB IL AO 2/SF/CN-PAC
Quantity in stock: 0
The Bosch Rexroth R-IB IL AO 2/SF/CN-PAC (R911172576) is a state-of-the-art analog output module designed for seamless integration within an Inline station. This high-resolution module is adept at outputting analog voltage or current signals, providing users with precise control and monitoring capabilities. With a resolution of 14 bits, it ensures accurate signal processing essential for various automation tasks. The module's flexibility is showcased by its ability to output signals in the ranges of 0...20 mA or 4...20 mA for current, and 0...10 V for voltage, catering to a wide range of application requirements. The connection technology utilized is the proven 3-wire connection technique, ensuring reliable and secure connections. Included with this module are essential accessories such as a connection plug and a labeling field, which facilitate easy installation and maintenance. The consecutive terminal point labeling further simplifies wiring and commissioning processes by providing clear identification for setup. The R-IB IL AO 2/SF/CN-PAC is designed to meet the stringent demands of modern industrial environments, offering both robustness and precision. It is an ideal solution for applications requiring high-quality analog signal output within the Bosch Rexroth Inline station ecosystem.
This module is designed for use within an Inline station. It is used to output analog voltage or current signals. The signals are provided with a resolution of 16 bits.
General data
|
Type |
R-IB IL AO 2/SF/CN-PAC | |
|
Color |
Gray | |
|
Weight 1) |
g |
190 |
|
Operating mode |
Process data mode with 2 words | |
|
Actuator connection type |
2-wire technology | |
|
Ambient temperature (operation) |
-25 °C ... +55 °C | |
|
Ambient temperature (storage/transport) |
-25 °C ... +85 °C | |
|
Permissible relative humidity (operation) |
10 % ... 95 % acc. to DIN EN 61131-2 | |
|
Permissible relative humidity (storage/transport) |
10 % ... 95 % acc. to DIN EN 61131-2 | |
|
Air pressure (operation) |
70 kPa ... 106 kPa (up to 3000 m above sea level) | |
|
Air pressure (storage/transport) |
70 kPa ... 106 kPa (up to 3000 m above sea level) | |
|
Protection type |
IP20 | |
|
Protection class |
III, IEC 61140, EN 61140, VDE 0140-1 | |
| 1) | Including plug |
Connection data
|
Type |
R-IB IL AO 2/SF/CN-PAC | |
|
Designation |
Inline connection plug | |
|
Connection type |
Spring-cage connection | |
|
Conductor cross-section solid/flexible/AWG |
0.2 mm² ... 1.5 mm² 0.2 mm² ... 1.5 mm² 24 ... 16 |
|
Interface local bus
|
Type |
R-IB IL AO 2/SF/CN-PAC | |
|
Connection type |
Inline data jumper | |
|
Transmission speed |
kBit/s |
500 |
|
Transfer physics |
Copper | |
Inline potentials/performance balance
|
Type |
R-IB IL AO 2/SF/CN-PAC | |
|
Logic voltage UL |
V DC |
7.5 |
|
Typical current consumption from UL |
mA |
36 |
|
Maximum current consumption from UL |
mA |
45 |
|
Analog supply voltage UANA |
V DC |
24 |
|
Typical current consumption from UANA |
mA |
75 |
|
Maximum current consumption from UANA |
mA |
95 |
|
Typical power consumption total |
W |
2.1 |
Analog outputs
|
Type |
R-IB IL AO 2/SF/CN-PAC | |||
|
Number of analog outputs 1) |
2 | |||
|
Signals/resolution in the process data bytes (quantization) |
For Inline |
Voltage 0 V ... 10 V |
0 V ... 10.837 V; 0.333 mV/LSB | |
|
Current 0 mA ... 20 mA |
0 mA ... 21.6764 mA; 0.667 μA/LSB | |||
|
Current 4 mA ... 20 mA |
4 mA ... 21.3397 mA; 0.553 μA/LSB | |||
|
For IB ST |
Voltage 0 V ... 10 V |
0 V ... 9.9975 V; 2.441 mV/LSB | ||
|
Current 0 mA ... 20 mA |
0 mA ... 19.9951 mA; 4.8828 μA/LSB | |||
|
Current 4 mA ... 20 mA |
4 mA ... 19.9961 mA; 3.906 μA/LSB | |||
|
Basic error limit |
% |
± 0.003 | ||
|
Output load voltage output |
kΩ |
≥ 2 | ||
|
Output load current output |
0 ... 500 | |||
|
Process data update of the assembly 2) |
ms |
< 1 | ||
| 1) | Configures dependent on terminal point used |
| 2) | Including conversion time of digital-analog converter |
Signal rise times
| 10 % ... 90 % | 0 % ... > 99 % | ||
|
Voltage output 0 V ... 10 V (typical data) |
|||
|
At no load |
µs |
44 | 72 |
|
Ohmic load RL = 2 kΩ |
µs |
46 | 74 |
|
Ohmic/capacitive load RL = 2 kΩ/CL = 10 nF |
µs |
47 | 95 |
|
Ohmic/capacitive load RL = 2 kΩ/CL = 220 nF |
µs |
79 | 350 |
|
Ohmic/inductive load RL = 2 kΩ/LL = 3.3 mH |
µs |
48 | 75 |
|
Power output 0 mA ... 20 mA (typical data) |
|||
|
Ohmic load RL = 500 Ω |
µs |
126 | 380 |
|
Ohmic/capacitive load RL = 500 Ω/CL = 10 nF |
µs |
140 | 425 |
|
Ohmic/capacitive load RL = 500 Ω/CL = 220 nF |
µs |
350 | 1200 |
|
Ohmic/inductive load RL = 500 Ω/LL = 3.3 mH |
µs |
110 | 368 |
|
Power output 4 mA ... 20 mA (typical data) |
|||
|
Ohmic load RL = 500 Ω |
µs |
140 | 508 |
|
Ohmic/capacitive load RL = 500 Ω/CL = 10 nF |
µs |
145 | 534 |
|
Ohmic/capacitive load RL = 500 Ω/CL = 220 nF |
µs |
380 | 1200 |
|
Ohmic/inductive load RL = 500 Ω/LL = 3.3 mH |
µs |
116 | 410 |
Tolerance and temperature behavior of outputs at TU = 25 °C
| Tolerance absolute, typical | Tolerance absolute, maximum | Tolerance relative, typical | Tolerance relative, maximum | |||
|
Output range |
0 V ... 10 V |
± 0.8 mV | ± 2 mV | ± 0.008 % | ± 0.02 % | |
|
0 mA ... 20 mA |
± 2 μA | ± 6 μA | ± 0.01 % | ± 0.03 % | ||
|
4 mA ... 20 mA |
± 2 μA | ± 6 μA | ± 0.01 % | ± 0.03 % | ||
Tolerance and temperature behavior of outputs at TU = -25 °C ... +55 °C
| Temperature coefficient maximum | Temperature coefficient typical | |||
|
Output range |
0 V ... 10 V |
ppm/K |
± 8 | ± 25 |
|
0 mA ... 20 mA |
ppm/K |
± 18 | ± 45 | |
|
4 mA ... 20 mA |
ppm/K |
± 18 | ± 45 | |
Protective devices
|
Type |
R-IB IL AO 2/SF/CN-PAC | |
|
Transient protection on voltage and current outputs |
Yes | |
Programming data
|
Type |
R-IB IL AO 2/SF/CN-PAC | |
|
ID code (hex) |
5B | |
|
ID code (dec) |
91 | |
|
Length code (hex) |
02 | |
|
Length code (dec) |
02 | |
|
Process data channel |
bits |
32 |
|
Input address room |
byte |
4 |
|
Output address room |
byte |
4 |
|
Parameter channel (PCP) |
byte |
0 |
|
Register length (bus) |
bits |
32 |
Fieldbus data telegram
|
Type |
R-IB IL AO 2/SF/CN-PAC | |
|
Need for parameter data |
byte |
6 |
|
Need for configuration data |
byte |
5 |
Error messages to the higher-level control or computer system
|
Type |
R-IB IL AO 2/SF/CN-PAC | |
|
Error message |
Upon failure or undershooting of the analog supply voltage UANA: Peripheral error message to the bus coupler | |
Electrical isolation/insulation of the voltage ranges
|
Type |
R-IB IL AO 2/SF/CN-PAC | |
|
Common potentials |
||
|
24 V peripheral voltage, 24 V segment voltage and GND are on the same potential. FE represents a separate potential area. |
||
|
Separate potentials in the system of bus coupler/feed module and I/O module |
||
|
Test distance |
Test voltage | |
|
7.5 V supply (bus logic), 24 V supply UANA/peripherals |
500 V AC, 50 Hz, 1 min. | |
|
7.5 V supply (bus logic), 24 V supply UANA/function earth |
500 V AC, 50 Hz, 1 min. | |
|
24 V supply (peripherals)/function earth |
500 V AC, 50 Hz, 1 min. | |
Mechanical tests
|
Type |
R-IB IL AO 2/SF/CN-PAC | |
|
Shock 1) |
15 g, 11 ms; 25 g, 6 ms; half sinusoidal shock pulse, 3 shocks per spatial direction | |
| 1) | Acc. to EN 60068-2-27/IEC 60068-2-27Deviation compared to DOK-CONTRL-ILSYSINS***-AW-DE-P |
|
Approvals |
|
The current approvals can be found at www.boschrexroth.com. |
Dimensions
|
Type |
R-IB IL AO 2/SF/CN-PAC | |
|
A |
mm |
48.8 |
|
B |
mm |
136.8 |
|
C |
mm |
72 |
|
Note on dimensions |