The Bosch Rexroth SLC-A-UE10-2FG3D0 (R911172295) is a relay module designed to enhance the functionality of the SafeLogic compact safety controller's base station. This module is equipped with two-channel outputs that utilize forcibly guided relay contacts, ensuring a high level of safety and reliability in operation. The inclusion of these outputs allows for the expansion of CPU modules with additional relay outputs, catering to more complex safety requirements. The SLC-A-UE10-2FG3D0 also features a return signaling path for contactor monitoring, known as Electrical Discharge Machining (EDM), which adds an extra layer of security by verifying the integrity and performance of connected contactors. This capability is critical in applications where contactor status feedback is necessary to maintain operational safety standards. Furthermore, this relay module offers scalability, as it can be extended to include up to several secure relay outputs per station. This flexibility makes it an ideal choice for systems that may require future expansion without the need for complete system overhauls. Overall, the Bosch Rexroth SLC-A-UE10-2FG3D0 relay module is an integral component for users seeking to upgrade their SafeLogic compact safety controllers with additional relay output capabilities while maintaining stringent safety protocols through reliable and secure connections.
The relay module upgrades the base station of the SafeLogic compact safety controller. The module provides two-channel outputs with contacts in the form of forcibly guided relay contacts.
General data
|
Type |
SLC-A-UE10-2FG3D0 | |
|
Weight 1) |
g |
86 |
|
Ambient temperature (operation) |
0 °C ... +55 °C | |
|
Protection type terminals |
IP20, EN 60529 | |
|
Protection type housing |
IP40, EN 60529 | |
| 1) | ±5 % |
Safety technological parameters
|
Type |
SLC-A-UE10-2FG3D0 | |
|
Safety integrity level acc. to IEC 61508 |
SIL 3 | |
|
Safety integrity level acc. to EN 62061 |
SILCL3 | |
|
Category acc. to EN ISO 13849-1 |
Category 4 | |
|
Performance level acc. to EN ISO 13849-1 |
PL e | |
|
PFHd acc. to EN ISO 13849 |
1.05*10-9 - |
|
|
B10d value |
1*105 switching cycles (AC-15, 230 V, I = 2 A) 2.5*105 switching cycles (AC-15, 230 V, I = 1 A) 5.4*105 switching cycles (DC-13, 24 V, I = 0.5 A) 1*107 switching cycles (DC-13, 24 V, I ≤ 2 A) |
|
|
TM (service life) acc. to EN ISO 13849 |
20 a | |
Electrical data
|
Type |
SLC-A-UE10-2FG3D0 | |
|
Protection class |
III, DIN EN 61140 | |
|
Type of voltage supply |
Via FLEXBUS+ | |
|
Internal power consumption |
W |
≤ 3.2 |
|
Switching current |
A |
≤ 6 |
|
Mechanical service life (relay contacts) |
1*107 switching cycles | |
|
Electrical service life (relay contacts) |
1*105 switching cycles | |
Interfaces
|
Type |
SLC-A-UE10-2FG3D0 | |
|
Contact type |
Forcibly guided | |
|
Number of safe contact outputs |
2 | |
|
Number of return signaling current paths |
1 | |
|
Cascadable |
No | |
|
Connection type |
Screw terminals | |
Dimensions
|
Type |
SLC-A-UE10-2FG3D0 | |
|
A |
mm |
17.8 |
|
B1 |
mm |
89.6 |
|
B2 |
mm |
105.5 |
|
C |
mm |
70.8 |