You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

BOSCH REXROTH
R911172291


$1,171.84 USD
  • BOSCH REXROTH
  • Material:R911172291
  • Model:SLC-3-XTIO84302

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Bosch Rexroth directly.***
The Bosch Rexroth SLC-3-XTIO84302 (R911172291) is a state-of-the-art digital input/output module designed for signal connection with safety peripherals. This module is specifically engineered to accommodate all standard sensors, thereby offering exceptional flexibility in terms of integration into various machine and plant setups. The inclusion of an integrated fast shutoff function significantly enhances the safety response time, contributing to the overall increased availability and efficiency of the machinery it's connected to. Equipped with SIL-rated safety inputs and outputs, the SLC-3-XTIO84302 ensures rigorous monitoring of the connected sensor system, maintaining a high level of safety during operation. The fast safety response facilitated by the module's design is crucial for applications requiring prompt action in critical situations. Additionally, the unit features diagnostic LEDs that simplify troubleshooting processes, allowing for easy identification and resolution of issues without the need for an additional gateway. The SLC-3-XTIO84302 module is also necessary when utilizing Bosch Rexroth's SLCAUERORO relay modules, as it complements their functionality and supports a seamless safety system architecture. Its straightforward diagnostics capabilities make it an indispensable component for any setup that prioritizes both operational efficiency and stringent safety protocols.

The digital input/output modules are used as a signal connection for the safety peripherals. The connection of all standard sensors provides maximum flexibility. The integrated fast shut-off function reduces the reaction times of the machines and plants and increases their availability. Simple diagnostics are made possible by means of standard outputs with no additional gateway.

General data

Type

SLC-3-XTIO84302

Weight 1)

g

164

Ambient temperature (operation)

-25 °C ... +55 °C

Ambient temperature (storage)

-25 °C ... +70 °C

Permissible relative humidity (operation)

10 ... 95%, no dewing

Climatic conditions

+55 °C ambient temperature, 95 % relative humidity, acc. to EN 61131-2

Electromagnetic compatibility (EMC)

Class A, acc. to EN 61000-6-2, EN 55011

Protection type terminals

IP20, EN 60529

Protection type housing

IP40, EN 60529
1) ±5 %

Safety technological parameters

Type

SLC-3-XTIO84302

Safety integrity level acc. to IEC 61508

SIL 3

Safety integrity level acc. to EN 62061

SILCL3

Category acc. to EN ISO 13849-1

Category 4

Performance level acc. to EN ISO 13849-1

PL e

PFHd acc. to EN ISO 13849

4.8*10-9, two-channel
0.9*10-9, single-channel

TM (service life) acc. to EN ISO 13849

20 a

Electrical data

Type

SLC-3-XTIO84302

Protection class

III, DIN EN 61140

Type of voltage supply

Via FLEXBUS+

Internal power consumption

W

≤ 2.2

Functions

Type

SLC-3-XTIO84302

Functions

Fast-Shut-Off, 8 ms

Interfaces

Type

SLC-3-XTIO84302

Number of safe inputs

8

Number of safe outputs

4

Connection type system connector

Tension spring modules

Mechanical tests

Type

SLC-3-XTIO84302

Vibration resistance

1 g, 5 … 150 Hz, acc. to EN 60068-2-6
3 g RMS, 10 … 500 Hz, acc. to EN 60068-2-64

Shock

30 g, 11 ms, acc. to EN 60068-2-27

Continuous shock

10 g, 16 ms, acc. to EN 60068-2-27

Relay module (2 outputs)

SLC-A-UE410-2RO4

technical illustration-R911172291-

Relay module (2 outputs)

SLC-A-UE410-2RO4

Extension of the CPU modules with relay outputs Two-channel outputs with forcibly guided contacts Return signaling path for contactor monitoring (EDM) Can be extended to include up to 16 secure relay outputs per station Can only be used with digital I/O module SLC-3-XTIO84302

Operating instructions

CAD Download

Relay module (4 outputs)

SLC-A-UE410-4RO4

technical illustration-R911172291-

Relay module (4 outputs)

SLC-A-UE410-4RO4

Extension of the CPU modules with relay outputs Two-channel outputs with forcibly guided contacts Return signaling path for contactor monitoring (EDM) Can be extended to include up to 16 secure relay outputs per station Can only be used with digital I/O module SLC-3-XTIO84302

Operating instructions

CAD Download

technical illustration-R911172291-

Dimensions

Type

SLC-3-XTIO84302

A

mm

22.5

B1

mm

96.5

B2

mm

5.1

B3

mm

5.1

C

mm

120.6