BOSCH REXROTH
R911172291
$1,171.84 USD
- BOSCH REXROTH
- Material:R911172291
- Model:SLC-3-XTIO84302
Quantity in stock: 0
The Bosch Rexroth SLC-3-XTIO84302 (R911172291) is a state-of-the-art digital input/output module designed for signal connection with safety peripherals. This module is specifically engineered to accommodate all standard sensors, thereby offering exceptional flexibility in terms of integration into various machine and plant setups. The inclusion of an integrated fast shutoff function significantly enhances the safety response time, contributing to the overall increased availability and efficiency of the machinery it's connected to. Equipped with SIL-rated safety inputs and outputs, the SLC-3-XTIO84302 ensures rigorous monitoring of the connected sensor system, maintaining a high level of safety during operation. The fast safety response facilitated by the module's design is crucial for applications requiring prompt action in critical situations. Additionally, the unit features diagnostic LEDs that simplify troubleshooting processes, allowing for easy identification and resolution of issues without the need for an additional gateway. The SLC-3-XTIO84302 module is also necessary when utilizing Bosch Rexroth's SLCAUERORO relay modules, as it complements their functionality and supports a seamless safety system architecture. Its straightforward diagnostics capabilities make it an indispensable component for any setup that prioritizes both operational efficiency and stringent safety protocols.
The digital input/output modules are used as a signal connection for the safety peripherals. The connection of all standard sensors provides maximum flexibility. The integrated fast shut-off function reduces the reaction times of the machines and plants and increases their availability. Simple diagnostics are made possible by means of standard outputs with no additional gateway.
General data
|
Type |
SLC-3-XTIO84302 | |
|
Weight 1) |
g |
164 |
|
Ambient temperature (operation) |
-25 °C ... +55 °C | |
|
Ambient temperature (storage) |
-25 °C ... +70 °C | |
|
Permissible relative humidity (operation) |
10 ... 95%, no dewing | |
|
Climatic conditions |
+55 °C ambient temperature, 95 % relative humidity, acc. to EN 61131-2 | |
|
Electromagnetic compatibility (EMC) |
Class A, acc. to EN 61000-6-2, EN 55011 | |
|
Protection type terminals |
IP20, EN 60529 | |
|
Protection type housing |
IP40, EN 60529 | |
| 1) | ±5 % |
Safety technological parameters
|
Type |
SLC-3-XTIO84302 | |
|
Safety integrity level acc. to IEC 61508 |
SIL 3 | |
|
Safety integrity level acc. to EN 62061 |
SILCL3 | |
|
Category acc. to EN ISO 13849-1 |
Category 4 | |
|
Performance level acc. to EN ISO 13849-1 |
PL e | |
|
PFHd acc. to EN ISO 13849 |
4.8*10-9, two-channel 0.9*10-9, single-channel |
|
|
TM (service life) acc. to EN ISO 13849 |
20 a | |
Electrical data
|
Type |
SLC-3-XTIO84302 | |
|
Protection class |
III, DIN EN 61140 | |
|
Type of voltage supply |
Via FLEXBUS+ | |
|
Internal power consumption |
W |
≤ 2.2 |
Functions
|
Type |
SLC-3-XTIO84302 | |
|
Functions |
Fast-Shut-Off, 8 ms | |
Interfaces
|
Type |
SLC-3-XTIO84302 | |
|
Number of safe inputs |
8 | |
|
Number of safe outputs |
4 | |
|
Connection type system connector |
Tension spring modules | |
Mechanical tests
|
Type |
SLC-3-XTIO84302 | |
|
Vibration resistance |
1 g, 5 … 150 Hz, acc. to EN 60068-2-6 3 g RMS, 10 … 500 Hz, acc. to EN 60068-2-64 |
|
|
Shock |
30 g, 11 ms, acc. to EN 60068-2-27 | |
|
Continuous shock |
10 g, 16 ms, acc. to EN 60068-2-27 | |
Relay module (2 outputs)
SLC-A-UE410-2RO4
Relay module (2 outputs)
SLC-A-UE410-2RO4
Extension of the CPU modules with relay outputs Two-channel outputs with forcibly guided contacts Return signaling path for contactor monitoring (EDM) Can be extended to include up to 16 secure relay outputs per station Can only be used with digital I/O module SLC-3-XTIO84302Operating instructions
CAD Download
Relay module (4 outputs)
SLC-A-UE410-4RO4
Relay module (4 outputs)
SLC-A-UE410-4RO4
Extension of the CPU modules with relay outputs Two-channel outputs with forcibly guided contacts Return signaling path for contactor monitoring (EDM) Can be extended to include up to 16 secure relay outputs per station Can only be used with digital I/O module SLC-3-XTIO84302Operating instructions
CAD Download
Dimensions
|
Type |
SLC-3-XTIO84302 | |
|
A |
mm |
22.5 |
|
B1 |
mm |
96.5 |
|
B2 |
mm |
5.1 |
|
B3 |
mm |
5.1 |
|
C |
mm |
120.6 |