The Bosch Rexroth R-IB IL TEMP 4/8 RTD-PAC (R911170428) is a highly precise and versatile analog input module designed for integration into a Rexroth Inline station. This specific module offers four to eight channels for reading temperatures through resistive temperature detectors (RTDs), making it an essential component for industrial automation systems that require accurate temperature monitoring and control. The R-IB IL TEMP 4/8 RTD-PAC supports three linear resistance ranges, catering to a variety of resistive temperature sensors. This module utilizes a wire connection technique to ensure secure and reliable communication with RTDs. It is engineered to streamline the temperature sensing process, which is crucial in maintaining optimal conditions in various applications. The provided accessories, including a connection plug and labeling field, facilitate easy installation and maintenance, while also promoting clear identification within complex systems. The R-IB IL TEMP 4/8 RTD-PAC's capability to interface with multiple sensor types makes it an adaptable solution for different thermal measurement needs. Its precision in reading resistance changes translates into accurate temperature data, which is vital for processes where temperature plays a critical role in product quality or safety. The module's robust design ensures consistent performance even in demanding industrial environments.
Inline connector
The modular, compact equipment configuration of the I/O systems from Rexroth offers you maximum flexibility for the cost-effective implementation of your individual machine concepts. The I/O modules have robust design and mechanics, are easy to use, have a quick reaction time and are quick to install – both in the control cabinet and in the field. Open communication standards allow you perfect integration of the I/O modules with maximum availability.
Unpacked Weight: 0.26 kg
This module is designed for use within a Rexroth Inline station. This module provides you with an 8-channel input module with three linear resistance ranges for resistive temperature sensors.
| Data Sheet | Download Data Sheet |
| Manual | Download Manual |
| Air pressure (operation) | 70-106 kPa (up to 3,000 m above sea level) |
| Supported sensor types | Pt, Ni, Cu, KTY, lineare Widerstände |
| Width | 48.8 |
| Productgroup ID | 4,6 |
| Height | 136.8 |
| International protection code | IP20 |
| Permissible air humidity (storage) | 10-95 |
| Permissible air humidity (transport) | 10-95 |
| Number of channels | 8 |
| Connection type | Zugfederanschluss |
| Connection techniques | 4-Leitertechnik |
| Depth | 72 |
| Weight | 0.26 |
| Ambient temperature (during operation) | -25-60 |
| Ambient temperature (storage and transport) | -25-85 |
| Conductor cross-section | Rigid: 0.08-0.5 mm²,Flexible: 0.08-0.5 mm²,AWG: 28 ... 16 |
General data
|
Type |
R-IB IL TEMP 4/8 RTD-EF-PAC | |
|
Color |
Green | |
|
Weight 1) |
g |
190 |
|
Operating mode |
Process data operation with 5 words/1 word PCP | |
|
Sensor connection type |
4-wire technology | |
|
Ambient temperature (operation) |
-25 °C ... +60 °C | |
|
Ambient temperature (storage/transport) |
-25 °C ... +85 °C | |
|
Permissible relative humidity (operation) |
10 % ... 95 % acc. to DIN EN 61131-2 | |
|
Permissible relative humidity (storage/transport) |
10 % ... 95 % acc. to DIN EN 61131-2 | |
|
Air pressure (operation) |
70 kPa ... 106 kPa (up to 3000 m above sea level) | |
|
Air pressure (storage/transport) |
70 kPa ... 106 kPa (up to 3000 m above sea level) | |
|
Protection type |
IP20, IEC 60529 | |
|
Protection class |
III, IEC 61140, EN 61140, VDE 0140-1 | |
| 1) | Including plug |
Connection data
|
Type |
R-IB IL TEMP 4/8 RTD-EF-PAC | |
|
Designation |
Inline connection plug | |
|
Connection type |
Spring-cage connection | |
|
Conductor cross-section solid/flexible/AWG |
0.08 mm² ... 1.5 mm² 0.08 mm² ... 1.5 mm² 28 ... 16 |
|
Interface local bus
|
Type |
R-IB IL TEMP 4/8 RTD-EF-PAC | |
|
Connection type |
Inline data jumper | |
|
Transmission speed |
kBit/s |
500 |
Inline potentials/performance balance
|
Type |
R-IB IL TEMP 4/8 RTD-EF-PAC | |
|
Logic voltage UL |
V |
7.5 |
|
Typical current consumption from UL |
mA |
95 |
|
Peripheral supply voltage UANA |
V DC |
24 |
|
Typical current consumption from UANA |
mA |
6 |
|
Typical power consumption total |
W |
0.85 |
Supply of module electronics and peripherals via bus coupler/power feed module
|
Type |
R-IB IL TEMP 4/8 RTD-EF-PAC | |
|
Connectivity technology |
Potential jumpers | |
Analog inputs
|
Type |
R-IB IL TEMP 4/8 RTD-EF-PAC | ||
|
Number of analog inputs 1) |
8 | ||
|
Resolution of the A/D converter |
bits |
24 | |
|
Measurement representation |
16 bits (15 bits + sign) - - - - - |
||
|
Measurement representation |
Standardized for |
Degrees Celsius (°C), degrees Fahrenheit (°F) and linear resistance in ohms (Ω) | |
|
Resolution (quantization) |
In the °C range |
0.1 K/LSB (factory setting); 0.01 K/LSB | |
|
In the °F range |
0.1 °F/LSB; 0.01 °F/LSB | ||
|
In the linear Ω range |
0.01 Ω/LSB; 0.1 Ω/LSB; 1 Ω/LSB | ||
|
Connectivity technology |
4-wire, shielded sensor line (e.g. LiYCY (TP)) | ||
|
Permissible cable length 2) |
m |
250 | |
|
Crosstalk attenuation |
Typ. 98.6 dB (channel/channel, external Pt100 connection, resolution 0.01 K/LSB) Typ. 100 dB (channel/channel, sensor type RLin500, resolution 0.01 Ω/LSB) Typ. 88 dB (channel/channel, sensor type RLin5000, resolution 0.1 Ω/LSB) |
||
|
Supported sensor types (RTD) |
Pt, Ni, Cu, KTY, linear resistors | ||
|
Characteristics standards |
DIN EN 60751: 07/1996 / SAMA RC 21-4-1966 | ||
|
Process data update |
Depending on the filter time | ||
|
Differential non-linearity |
Typ. 1 ppm/±0.0001 % (in all areas) | ||
|
Integral non-linearity |
Typ. 30 ppm/±0.003 % (Pt100) Typ. 20 ppm/±0.002 % (RLin 500 Ω) Typ. 200 ppm/±0.02 % (RLin 5000 Ω) |
||
| 1) | 4-wire RTD for resistive temperature sensors |
| 2) | 4-wire connection with LiYCY (TP) 2 x 2 x 0.5 mm² |
Conformity
|
Type |
R-IB IL TEMP 4/8 RTD-EF-PAC | ||
|
Conforms with |
|||
|
Testing of interference immunity acc. to EN 61000-6-2 |
Electro-magnetic fields |
Criterion A; level: 10 V/m; additional tolerance of the measurement range end value: < 0.1 % acc. to EN 61000-4-3/IEC 61000-4-3 | |
|
Fast transients (burst) |
Criterion A; level: 1.1 kV acc. to EN 61000-4-4/IEC 61000-4-4 | ||
|
Line-fed disturbances |
Criterion A; level: 150 kHz ... 80 MHz, test voltage 10 V, 80 % AM (1 kHz) acc. to EN 61000-4-6/IEC 61000-4-6 | ||
|
Line-fed disturbances (ODS) |
Criterion A; level: 150 kHz ... 300 MHz, test voltage 30 V, 80 % AM (1 kHz) acc. to EN 61000-4-6/IEC 61000-4-6 | ||
Protective devices
|
Type |
R-IB IL TEMP 4/8 RTD-EF-PAC | |
|
Transient protection of the inputs |
Yes | |
|
Sensor supply voltage |
Yes | |
Electrical isolation/insulation of the voltage ranges
|
Type |
R-IB IL TEMP 4/8 RTD-EF-PAC | |
|
For the potential separation of the logic layer from the peripheral area, it is necessary to use separate power supplies when supplying the station's bus coupler and the sensors that are connected to the analog input terminal described here. A connection to the supply units in the 24 V range is not allowed. |
||
|
Common potentials |
||
|
24 V main voltage, 24 V segment voltage and GND are on the same potential. FE represents a separate potential area. |
||
|
Separate potentials in the system of bus coupler/feed module and I/O module |
||
|
Test distance |
Test voltage | |
|
5 V supply incoming remote bus/7.5 V supply (bus logic) |
500 V AC, 50 Hz, 1 min. | |
|
5 V supply to further remote bus/7.5 V supply (bus logic) |
500 V AC, 50 Hz, 1 min. | |
|
7.5 V supply (bus logic), 24 V supply UANA/peripherals |
500 V AC, 50 Hz, 1 min. | |
|
7.5 V supply (bus logic), 24 V supply UANA/function earth |
500 V AC, 50 Hz, 1 min. | |
|
Peripherals/function earth |
500 V AC, 50 Hz, 1 min. | |
Error messages to the higher-level control or computer system
|
Type |
R-IB IL TEMP 4/8 RTD-EF-PAC | |
|
Error message |
Failure of the internal, galvanically-isolated peripheral voltage supply Failure or undershooting of the logic voltage UL - - |
|
|
Error messages about process data |
||
|
Error message |
Peripheral / user error | |
|
Approvals |
|
The current approvals can be found at www.boschrexroth.com. |
Dimensions
|
Type |
R-IB IL TEMP 4/8 RTD-EF-PAC | |
|
A |
mm |
48.8 |
|
B |
mm |
136.8 |
|
C |
mm |
72 |
|
Note on dimensions |
The depth applies when using a support rail TH 35-7.5 (acc. to EN 60715). | |