BOSCH REXROTH
R901281640
$1,152.14 USD
- BOSCH REXROTH
- Material:R901281640
- Model:Z2S6-1-6X//60SO55
Quantity in stock: 0
The Bosch Rexroth Z2S6-1-6X//60SO55 (R901281640) is a sophisticated isolator valve designed for precise control in hydraulic systems. This releasable check valve, part of the ZS series, is engineered to enable leak-free blocking of one or two actuator ports even over extended periods of inactivity. Its sandwich plate design allows for easy integration into vertical stacking arrangements and is compatible with porting patterns according to DIN form A and ISO with locating hole. The model features a control spool and poppet mechanism that facilitates free flow in one direction (A to A or B to B) while securely blocking the opposite direction until released by the control spool movement. This functionality ensures that hydraulic fluid can flow freely when needed, while maintaining a solid block when required. The presence of preopening in this model provides damped decompression of pressurized liquid, effectively minimizing potential switching shocks that could otherwise cause premature wear or noise. This valve has been built to withstand maximum operating pressures and accommodate significant flow rates, ensuring reliable performance in demanding applications. It also offers various cracking pressures as per ordering codes and comes with optional check valve installation sets for added versatility. The Z2S6-1-6X//60SO55 is particularly valuable for applications requiring secure isolation without leakage, even during long periods of downtime. Its robust design and preopening feature make it suitable for systems where smooth operation and protection against pressure spikes are critical. Whether used individually or as part of a complex hydraulic circuit, this Bosch Rexroth isolator valve stands out for its reliability and advanced functionality.
The isolator valve type Z2S is a releasable check valve in sandwich plate design.
It is used for the leakage-free blocking of one or two actuator ports, also in case of longer standstill times.
In direction A① to A② or B① to B②, there is a free flow; in the opposite direction, the flow is blocked.
If, for example, there is a flow through the valve in direction A① to A②, the control spool (1) is moved in the direction of the B side, opens the ball seat valve (2) and then pushes the poppet (3) off its seat. Hydraulic fluid can now flow from B➁ to B➀.
In order to allow the ball seat valve (2) to be safely closed, the control spool (1) must be hydraulically unloaded (see circuit example).
Pre-opening
Due to the pre-opening, there is a damped decompression of the pressurized liquid. Thus, possible switching shocks are avoided. The two-stage set-up with an increased control open ratio means even low pilot pressure can be unloaded securely.
Notice:
In valves without pre-opening, sudden unloading of pent-up pressure volume may occur. Resulting switching shocks may lead to premature wear on installed components, as well as noise formation.
|
1 |
Control spool, area A2 |
|
2 |
Poppet, area A1 |
|
3 |
Stop |
Type Z2S 6 A…SO40
Type Z2S 6 A…SO60
|
1 |
Control spool, area A2 |
|
2 |
Poppet, area A1 |
|
3 |
Stop |
|
4 |
Control spool, area A4 |
|
5 |
Pre-opening, area A3 |
Type Z2S 6 -…SO55 (with pre-opening)
1) Corrosion-resistant surface on request: e.g."J50" thick film passivated (DIN 50979 Fe//Zn8//Cn//T0)
2) Locking pin ISO 8752-3x8-St, material no. R900005694 (separate order)
|
01 |
02 |
03 |
04 |
05 |
06 |
07 |
08 |
09 |
10 |
||
|
Z2S |
6 |
– |
6X |
/ |
* |
|
01 |
Check valve, Sandwich plate design |
Z2S |
|
02 |
Size 6 |
6 |
|
Leakage-free blocking |
||
|
03 |
In channel A and B |
– |
|
In channel A |
A |
|
|
In channel B |
B |
|
|
Cracking pressure |
||
|
04 |
1,5 bar |
1 |
|
3 bar |
2 |
|
|
6 bar |
3 |
|
|
05 |
Component series 60 … 69 (60 … 69: unchanged installation and connection dimensions) |
6X |
|
06 |
Surface without corrosion resistance 1) |
no code |
|
Seal material |
||
|
07 |
NBR seals |
no code |
|
FKM seals |
V |
|
|
The selection is dependent on the operating parameters (hydraulic fluid, temperature, etc.)! |
||
|
Locating hole |
||
|
08 |
no code |
|
|
With locating hole |
/60 |
|
|
With locating hole and locking pin ISO 8752-3x8-St 2) |
/62 |
|
|
Special version |
||
|
09 |
Without special version |
no code |
|
Control open by external port G1/4 (only version "A" and "B") |
SO40 |
|
|
With pre-opening |
SO55 |
|
|
Control spool unloaded to port T |
SO60 |
|
|
With pre-opening and control open from channel P |
SO150 |
|
|
Symbols (examples) see "Symbols/Circuit diagrams" |
||
|
10 |
Further details in the plain text |
* |
general
|
Size |
6 | ||
|
Weight |
kg |
0.8 | |
|
Installation position |
any | ||
|
Ambient temperature range |
NBR seals |
°C |
-30 … +80 |
|
FKM seals |
°C |
-20 … +80 | |
hydraulic
|
Size |
6 | ||
|
Maximum operating pressure |
bar |
315 | |
|
Cracking pressure 1) |
bar |
1.5 / 3 / 6 | |
|
Maximum flow |
l/min |
60 | |
|
Direction of flow |
see symbols | ||
|
Hydraulic fluid |
see table | ||
|
Hydraulic fluid temperature range (NBR seals) |
°C |
-30 … +80 | |
|
Hydraulic fluid temperature range (FKM seals) |
°C |
-20 … +80 | |
|
Viscosity range |
mm²/s |
2.8 … 500 | |
|
Maximum admissible degree of contamination of the hydraulic fluid 2) |
Class 20/18/15 according to ISO 4406 (c) | ||
|
Area ratio |
Without pre-opening |
A1/A2 ~ 1/3.5 (see sectional drawing) | |
|
With pre-opening |
A3/A2 ~ 1/12.5 (see sectional drawing) | ||
|
Version "SO60" |
A1/A4 ~ 1/7 (see sectional drawing) | ||
| 1) | in free direction |
| 2) | The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter. |
Selection of optimal sealing material also depends on the type of hydraulic fluid used.
For applications outside these parameters, please consult us!
|
Hydraulic fluid |
Classification |
Suitable sealing materials |
Standards |
|
|
Mineral oils |
HL, HLP, HLPD |
NBR, FKM |
DIN 51524 |
|
|
Bio-degradable |
Insoluble in water |
HETG |
NBR, FKM |
VDMA 24568 |
|
HEES |
FKM |
|||
|
Soluble in water |
HEPG |
FKM |
VDMA 24568 |
|
|
Flame-resistant |
Water-free |
HFDU, HFDR |
FKM |
ISO 12922 |
|
Containing water |
HFC (Fuchs Hydrotherm 46M, Petrofer Ultra Safe 620) |
NBR |
ISO 12922 |
|
Important information on hydraulic fluids!For further information and data on the use of other hydraulic fluids, please refer to data sheet 90220 or contact us! There may be limitations regarding the technical valve data (temperature, pressure range, life cycle, maintenance intervals, etc.)! The flash point of the hydraulic fluid used must be 40 K higher than the maximum solenoid surface temperature.Flame-resistant – containing water: Maximum operating pressure 210 bar Maximum hydraulic fluid temperature 60 °C Life cycle compared to operation with mineral oil HL, HLP 30 to 100 % |
||||
(measured with HLP46, ϑOil = 40 ±5 °C)
Δp-qV characteristic curves
Δp-qV characteristic curves
Circuit example, schematic
|
① |
component side |
|
② |
plate side |
Type Z2S 6 A…
Type Z2S 6 -… and Z2S 6 -…SO55
Type Z2S 6 B…
Type Z2S 6 A…SO40
Type Z2S 6 A…SO60
Type Z2S 6 -…SO150
|
➀ |
component side |
|
➁ |
plate side |
Dimensions in mm
Dimensions in mm
|
Type |
L1 |
|
mm |
|
| Z2S 6...ohne Bez. | 11 |
| Z2S 6...SO40 | 11 |
| Z2S 6...SO55 |
11 1) 21.5 1) |
| Z2S 6...SO60 | 11 |
| Z2S 6...SO150 | 21.5 |
| 1) | Maximum dimension on the side of the check valve cartridge |
|
➀ |
component side – porting pattern according to DIN 24340 form A (without locating hole), or ISO 4401-03-02-0-05 (with locating hole Ø4 x 4 mm deep) and NFPA T3.5.1 R2-2002 D03 |
|
➁ |
plate side – porting pattern according to DIN 24340 form A (without locating hole), or ISO 4401-03-02-0-05 (with locating hole for locking pin ISO 8752-3x8-St; version "/60" and "/62") and NFPA T3.5.1 R2-2002 D03 |
|
3 |
Name plate |
|
4 |
Through hole for valve mounting |
|
5 |
Identical seal rings for ports A, B, P, and T |
|
6 |
Locking pin ISO 8752-3x8-St (only version "/62") |
|
7 |
Plug screw SW22 |
Valve mounting screws (separate order)
4 hexagon socket head cap screws ISO 4762 - M5 - 10.9
4 hexagon socket head cap screws N10-24 UNC
Notice!
The length of the valve mounting screws of the sandwich plate valve must be selected according to the components mounted under and over the isolator valve.
Depending on the application, screw type and tightening torque must be adjusted to the circumstances.
Please ask Rexroth for screws with the required length.
Type Z2S 6 -… (with pre-opening)
Type Z2S 6 A…
|
➀ |
component side |
|
➁ |
plate side |