BOSCH REXROTH
R901183009
$44,511.26 USD
- BOSCH REXROTH
- Material:R901183009
- Model:VT-MAC8-1X/S5-AM4-1AX4
Quantity in stock: 0
The Bosch Rexroth VT-MAC8-1X/S5-AM4-1AX4 (R901183009) is a highly sophisticated digital multiaxis NC control designed for complex automation tasks. This modular system can start with a master card that accommodates no or one axis controller, and it can be expanded to include up to seven slave cards, each capable of managing four axes. This scalability allows the VT-MAC8-1X/S5-AM4-1AX4 to handle up to 28 interpolatable axes, making it an ideal solution for intricate control challenges. The unit's connectivity options are versatile, supporting local Ethernet connections for linking multiple MAC units. Additionally, it offers communication with superior PLC machine controls through field bus interfaces such as PROFIBUS DP or CAN, as well as via Ethernet. The VT-MAC8-1X/S5-AM4-1AX4 excels in hydraulic control applications thanks to its specialized hydraulic control characteristics, which enable it to automate machine movements precisely and autonomously. Furthermore, this control unit can take on PLC tasks, ensuring seamless integration into a variety of automation systems. With its ability to analyze and activate sensors and actuators over the CAN bus, the VT-MAC8-1X/S5-AM4-1AX4 provides comprehensive control capabilities for engineers looking to optimize their machinery's performance through advanced automation technology. Its design caters specifically to those requiring precise and reliable control over multi-axis operations within their automated systems.
|
01 |
02 |
03 |
04 |
05 |
06 |
07 |
08 |
09 |
10 |
||||
|
VT-MAC8 |
– |
1X |
/ |
S |
– |
M |
– |
AX4 |
* |
|
01 |
VT-MAC8 |
|
|
02 |
1X |
|
|
03 |
S |
|
|
System with |
||
|
04 |
1 slot |
1 |
|
5 slots |
5 |
|
|
8 slots |
8 |
|
|
Bus variant |
||
|
05 |
No field bus |
A |
|
PROFIBUS DP slave connection |
P |
|
|
PROFINET RT / EtherNET/IP slave connection |
E |
|
|
06 |
M |
|
|
Master |
||
|
07 |
without axis module, with RS485 |
1 |
|
2-axis version, with RS485 |
2 |
|
|
4-axis version |
4 |
|
|
4-axis slave |
||
|
08 |
Quantity |
0 to 7 |
|
09 |
AX4 |
|
|
10 |
Further details in the plain text |
|
General
|
Component series |
1X |
Voltage supply
|
Operating voltage |
UB |
18 to 36 VDC / max. 3.6 A | ||
|
Current consumption |
Master without axes |
mA |
500 | |
|
Master with axes |
mA |
800 | ||
|
Slave |
mA |
400 | ||
Analog inputs
|
Voltage inputs (differential inputs) |
Input voltage, max. |
UE |
max.+10 V to –10 V; 12 bits with 4-fold oversampling | |
|
Input resistance |
Re |
kΩ |
160 | |
|
Resolution |
mV |
5 | ||
|
Current inputs |
Input current |
Ie |
mA |
± 20 |
|
Ie |
4 to 20 mA | |||
|
Input resistance |
Re |
Ω |
100 | |
|
Re |
Ω |
500 | ||
|
Leakage current |
Iv |
μA |
12 | |
|
Resolution |
μA |
4 |
Digital inputs
|
Number |
32 | ||
|
Logic level |
log 0 (low) 0 V to +5 V | ||
| log 1 (high) +10 V to 36 V | |||
|
Input resistance |
Re |
3 kΩ ±10 % |
Analog outputs
|
Voltage outputs |
Output voltage |
U |
±10 V PWM (pulse width modulation) | |
|
Current, max. |
Imax |
mA |
10 | |
|
Load, min. |
Rmin |
kΩ |
2 | |
|
Current outputs |
Output current, normalized |
Inom |
mA |
± 20 |
|
Load, max. |
Rmax |
Ω |
500 | |
|
Resolution |
mV |
1 |
Digital outputs
|
Number |
24 | |
|
Logic level |
log 0 (low) 0 V to +5 V | |
| log 1 (high) +10 V to 36 V | ||
|
Connection |
A |
≤ 50 |
Digital position transducers
|
Incremental transducer with TTL output |
Input voltage |
log 0 |
0 to 1 V | ||
|
log 1 |
2.8 to 5.5 V | ||||
|
Input current |
log 0 |
–0.8 mA (with 0 V) | |||
|
log 1 |
0.8 mA (with 5 V) | ||||
|
Frequency, max. related to Ua1 |
fmax |
250 kHz, 24 bit | |||
|
SSI transducer |
Coding |
Gray code | |||
|
Data width |
adjustable up to max. 28 bit | ||||
|
Line receiver (TTL) |
fmax |
kHz |
250 | ||
|
Input voltage |
log 0 |
0 to 1 V | |||
|
log 1 |
2.5 to 5.5 V | ||||
|
Input current |
log 0 |
-0.5 mA (with 0 V) | |||
|
log 1 |
0.5 mA (with 5 V) | ||||
|
Output voltage |
log 0 |
0 to 0.5 V | |||
|
log 1 |
2.5 to 5.5 V | ||||
Other characteristics
|
Processor |
MPC860 and MPC555 | |||
|
Accumulators |
16 MB SDRAM, 16 MB Flash, 8 KByte DPR, 4 MB Flash (MPC555), 2 MB SRAM (MPC555) |
|||
|
Interfaces, serial |
Standard |
RS232 (V 24) (19.2 KBaud) RS485 (115 KBaud) |
||
|
optional |
PROFIBUS DP (max. 12 MBaud) CANopen (max. 1 MBaud) |
|||
|
Operating temperature range |
ϑ |
0 … +50 °C | ||
|
Storage temperature range |
ϑ |
-20 … +70 °C | ||
|
Weight |
Rack 1 |
m |
1000 g | |
|
Rack 5 |
m |
1800 g | ||
|
Rack 8 |
m |
2500 g | ||
|
Master card |
m |
400 g | ||
|
Slave card |
m |
350 g | ||
|
Blank cover |
m |
100 g | ||
For applications outside these parameters, please consult us!
System overview
Pin assignment master card VT-MAC8
Pin assignment master card VT-MAC8
Pin assignment master card VT-MAC8
Pin assignment slave card VT-MAC8-1X/K-AX4
VT-MAC8-1X/K-RACK5 VT-MAC8-1X/K-RACK1
System with 5 slots System with 1 slot
Dimensions in mm
VT-MAC8-1X/K-RACK8
System with 8 slots
Dimensions in mm
VT-MAC8-1X/K-RACK1/5/8
Dimensions in mm