BOSCH REXROTH
R901158978
$13,661.42 USD
- BOSCH REXROTH
- Material:R901158978
- Model:4WRVE16V200M-2X/G24EK0/B5M
Quantity in stock: 0
The Bosch Rexroth 4WRVE16V200M-2X/G24EK0/B5M (R901158978) is a high-performance directional control valve designed for advanced hydraulic system applications requiring precise control and fast response times. This valve is part of the WRVE series, which are pilot-operated, high-response valves with servo quality. It features integrated electronics OBE with a position controller for both the pilot and main stage, ensuring the valve is finely tuned and calibrated right at the plant for optimal performance. The main stage of the 4WRVE16V200M-2X/G24EK0/B5M valve exhibits servo quality with position feedback, which allows for accurate positioning and smooth operation under various load conditions. The flow characteristics of this model include a progressive and fine control edge (M), an inflected characteristic curve (P), and a linear flow (L), providing versatility to meet different application requirements. With its size denoted as Component series X, this valve can handle maximum operating pressures up to bar levels specified by the manufacturer and supports a maximum flow rate in liters per minute as indicated. The nominal flow rate is also provided in liters per minute, ensuring users can match the valve's capabilities to their system's requirements. This Bosch Rexroth valve is engineered for use in applications where high dynamics and precision are essential, making it suitable for a wide range of industrial hydraulic systems.
Valves of type 4WRVE are pilot-operated high-response valves in servo quality.
|
01 |
02 |
03 |
04 |
05 |
06 |
07 |
08 |
09 |
10 |
11 |
12 |
13 |
14 |
|||
|
4 |
WRV |
E |
‒ |
2X |
/ |
G24 |
K0 |
/ |
B5 |
M |
* |
|
01 |
4 main ports |
4 |
|
02 |
High-response directional valve, pilot operated |
WRV |
|
03 |
With integrated electronics (OBE) |
E |
|
04 |
Size 10 |
10 |
|
Size 16 |
16 |
|
|
Size 25 |
25 |
|
|
Size 27 |
27 1) |
|
|
05 |
Symbols; for the possible version, see "Symbols/Circuit diagrams" |
V, V1 |
|
Rated flow (Δp = 5 bar) |
||
|
06 |
Size 10 |
|
|
40 l/min |
40 2) |
|
|
55 l/min |
55 3) |
|
|
70 l/min |
70 2) |
|
|
85 l/min |
85 3) |
|
|
Size 16 |
||
|
90 l/min |
90 2) |
|
|
120 l/min |
120 3) |
|
|
150 l/min |
150 2) |
|
|
200 l/min |
200 3) |
|
|
Size 25 |
||
|
300 l/min |
300 2) |
|
|
370 l/min |
370 3) |
|
|
Size 27 |
||
|
430 l/min |
430 1) 3) |
|
|
Flow characteristic |
||
|
07 |
Progressive with linear fine control range |
M |
|
Inflected characteristic curve, linear (inflection at 40 %) |
P |
|
|
Linear |
L |
|
|
08 |
Component series 20 ... 29 (20 ... 29: unchanged installation and connection dimensions) - Size 6 |
2X |
|
Supply voltage of the control electronics |
||
|
09 |
Direct voltage 24 V |
G24 |
|
Pilot oil supply and return |
||
|
10 |
External pilot oil supply, external pilot oil return |
no code |
|
Internal pilot oil supply, external pilot oil return |
E |
|
|
Pilot oil supply internal, pilot oil return internal |
ET |
|
|
External pilot oil supply, internal pilot oil return |
T |
|
|
Electrical connection |
||
|
11 |
Without mating connector; connector DIN 43563-AM6 |
K0 |
|
Electrical interface |
||
|
12 |
Command value ±10 V |
B5 |
|
Seal material |
||
|
13 |
NBR seals |
M |
|
14 |
Further details in the plain text |
* |
|
1) |
NG27 is a high-flow version of NG25, the connection bores P, A, B, T in the main stage are designed with Ø32 mm. Deviating from the standard ISO 4401-08-08-0-05, ports P, A, B, T can be bored in the manifold with a maximum of Ø30 mm. So these valves offer higher flow values QA : QB |
|
|
2) |
QN: flow characteristic P |
|
|
3) |
QN: flow characteristic M or L |
|
For applications outside these parameters, please consult us!
general
|
Type |
4WRVE | ||||
|
Size |
10 | 16 | 25 | 27 | |
|
Component series |
2X | ||||
|
Design |
Directional spool valve, pilot-operated | ||||
|
Type of actuation |
High-response directional valve NG6 with position control for pilot control and main valve | ||||
|
Anschlussart |
For subplate mounting: Porting pattern according to ISO 4401 | ||||
|
Installation position |
Any | ||||
|
Earth |
kg |
8 | 10.4 | 18.2 | |
|
Ambient temperature range |
°C |
-20 … +50 | |||
hydraulic
|
Type |
4WRVE | ||||||
|
Size |
10 | 16 | 25 | 27 | |||
|
Maximum operating pressure |
bar |
350 | |||||
|
Maximum operating pressure |
Port T |
bar |
250 | ||||
|
Port Y |
bar |
250 | |||||
|
Port X |
bar |
250 | |||||
|
Maximum operating pressure |
Port P |
External pilot oil supply |
bar |
350 | |||
|
Port A |
bar |
350 | |||||
|
Port B |
bar |
350 | |||||
|
Maximum operating pressure |
Port P |
Internal pilot oil supply |
bar |
250 | |||
|
Port A |
bar |
250 | |||||
|
Port B |
bar |
250 | |||||
|
Nominal flow 1) |
l/min |
40 55 70 85 |
90 120 150 200 |
300 370 |
430 | ||
|
Nominal flow |
Pilot control valve |
l/min |
8 | 24 | 40 | ||
|
Maximum flow |
l/min |
170 | 450 | 900 | 1000 | ||
|
Hydraulic fluid temperature range |
°C |
-20 … +65 | |||||
|
Viscosity range |
mm²/s |
10 … 800 | |||||
|
preferably |
mm²/s |
20 … 100 | |||||
|
Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 2) |
Class 18/16/13 according to ISO 4406 (c) | ||||||
|
Hysteresis |
% |
< 0.1 | |||||
|
Manufacturing tolerance |
% |
≤ 10 | |||||
|
Temperature drift |
% |
< 1 | |||||
|
Actuating time |
0 ... 100 % |
ms |
12 | 15 | 23 | ||
|
0 ... 10 % |
ms |
6 | 7 | 10 | |||
|
Actuating time |
0 ... 100 % |
Symbol E, E1-, W6-, W8- |
ms |
40 | 50 | 90 | |
| 1) | Δp = 5 bar per edge |
| 2) | The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter. |
electrical
|
Type |
4WRVE | ||
|
Power supply |
Nominal voltage |
V |
24 |
|
Lower limit value |
V |
21 | |
|
Upper limit value |
V |
40 | |
|
Duty cycle |
% |
100 | |
|
Maximum power consumption |
VA |
30 | |
|
Required fuse protection |
AT |
2.5 AF | |
|
Protection class according to DIN EN 60529 |
IP65 (with mating connector mounted and locked) | ||
|
EMC (electro-magnetic compatibility) |
CE conformity according to EMC directive 2004/108/EC tested according to EN 61000-6-2 and EN 61000-6-3 | ||
|
Zero point calibration 1) |
% |
± 1 | |
| 1) | ex works |