BOSCH REXROTH
R901088813
$441.05 USD
- BOSCH REXROTH
- Material:R901088813
- Model:ABZMS-35-1X/120F090S-T70F-K24
Quantity in stock: 0
The Bosch Rexroth ABZMS-35-1X/120F090S-T70F-K24 (R901088813) is a precision-engineered float switch designed to monitor and control fluid levels within tanks, particularly suited for small power units of the ABSKG series. This device features dual reed contacts—one normally closed and one normally open—that are activated by permanent magnets in the float as fluid levels change. These contacts switch states when the magnetic float reaches predetermined points, with their positions maintained until the float moves past these points with changing oil levels. The ABZMS-35-1X/120F090S-T70F-K24 offers versatility through its optional contact function at switching point L, allowing users to choose between a normally closed or normally open contact setup based on specific requirements. Additionally, this model includes a temperature monitoring feature that employs a bimetal plate sensitive to temperature changes. When a preset temperature threshold is reached, the device activates a switch, providing an essential shutdown function to prevent overheating of the hydraulic fluid. This level switch operates on a simple yet effective principle: as the oil level falls, the float descends to the switching points and magnetically actuates the contacts. This action is reversed when the oil level rises, ensuring consistent and reliable monitoring of fluid levels within the system. The model's design ensures durability and long-term operation in various applications where precise fluid level control is critical. Its integrated temperature contact adds an extra layer of safety by alerting system operators or triggering automatic shutdowns if maximum hydraulic fluid temperatures are exceeded, thus preventing potential damage to equipment due to overheating.
Float switches are switching devices operated by a float moved by fluid. They are used to control the tank fluid levels in small power units type ABSKG ... NG10; 20; 40 and 60.
The sliding tubes contain two fixedly set reed contacts (normally closed contact and normally open contact) that are switched by the permanent magnets installed in the float.
Fixedly set temperature contacts (option) are fitted to monitor the max. hydraulic fluid temperature.
Function of level switch
When the float reaches the switching points while the oil level is falling, the contacts are operated magnetically. The switching positions of the contacts are maintained until the float passes the switching points again due to a rising oil level.
Switching point L1 is a normally closed contact, the contact function of switching point L2 is optionally a normally closed or normally open contact.
Level switch function
When the float reaches the switching points while the oil level is falling, the contacts are operated magnetically. The switching positions of the contacts are maintained until the float passes the switching points again due to a rising oil level.
Switching point L1 is a normally closed contact, the contact function of switching point L2 is optionally a normally closed or normally open contact.
Temperature contact function
A bimetal plate, which is influenced by temperature, switches when a firmly set response temperature is reached. The temperature contact is not suitable for temperature controlling, but merely for a shutdown function.
Ordering code
01 |
02 |
03 |
04 |
05 |
06 |
07 |
08 |
09 |
10 |
|||||
ABZM |
S |
‒ |
35 |
‒ |
1X |
/ |
F |
‒ |
‒ |
V |
Power unit accessories |
||
01 |
Measuring devices |
ABZM |
02 |
Float switches |
S |
03 |
Version |
35 |
04 |
Component series 10 ... 19 (10 ... 19: unchanged installation and connection dimensions) |
1X |
Minimum contact |
||
05 |
Switching point L1 in mm |
… |
06 |
Normally closed contact |
F |
Maximum contact |
||
07 |
Switching point L2 in mm |
… |
08 |
Normally closed contact |
F |
Normally open contact |
S |
|
Temperature contact |
||
09 |
Without switching contact |
no code |
Switching contact normally closed contact at 63 °C |
T63F1) |
|
Switching contact normally closed contact at 70 °C |
T70F |
|
Switching contact normally closed contact at 80 °C |
T80F1) |
|
Electrical connection 2) |
||
10 |
Connector, 4-pole M12 x 1 |
K24 |
Connector 4-pole (3 + PE) DIN EN 175301-803 (float switch without temperature contact) |
K14 |
|
Connector 7-pole (6 + PE) DIN EN 175201-804 (float switch without temperature contact) |
K6 |
1) | Only upon request |
2) | The mating connectors are not included in the scope of delivery and must be ordered separately, if required (see R.08006) |
Order example: Float switch with connection thread M20 x 1.5, with 2 fixedly set switching contacts, switching point L1 = 90 mm normally closed contact, switching point L2 = 30 mm normally open contact, connector K24 for mating connector Z24 (M12 x 1): |
|
ABZMS-35-1X/090F030S-K24 |
Resistance
Hydraulic fluids |
||||
Mineral oils |
Mineral oil |
HLP |
according to DIN 51524 |
Resistant |
Flame-resistant hydraulic fluids |
Emulsions |
HFA-E |
according to DIN 24320 |
Not resistant |
Water solutions |
HFC |
according to VDMA 24317 |
||
Phosphoric acid esters |
HFD-R |
|||
Organic esters |
HFD-U |
|||
Fast bio-degradable hydraulic fluids |
Triglycerides (rape seed oil) |
HETG |
according to VDMA 24568 |
|
Synthetic esters |
HEES |
|||
Polyglycols |
HEPG |
electrical
Plug-in connection |
4-pole M12 x 1 (material: metal) DIN EN 175301-803/DIN EN 175201-804 |
Reed contacts of the float switches
with connection K24 for mating connector M12 x 1; 4-pole
Switching voltage range |
V DC |
10 … 50 |
Maximum switching current |
A |
0.5 |
Maximum switching power |
W |
10 |
Temperature contacts of the float switches
with connection K24 for mating connector M12 x 1; 4-pole
Switching voltage range |
V DC |
10 … 50 |
Maximum switching current |
A |
2 |
Maximum switching cycles |
10000 | |
Response tolerance |
K |
± 4 |
Hysteresis range |
K |
2 … 10 |
Maximum temperature change velocity |
K/min |
1 |
Reed contacts of the float switches
with connection K14 according to DIN EN 175301-803 / K6 according to DIN EN 175201-804
Switching voltage range |
V AC |
10 … 230 |
Maximum switching current |
A |
0.5 |
Maximum switching power |
10 W; 30 VA |
Temperature contacts of the float switches
with connection K14 according to DIN EN 175301-803 / K6 according to DIN EN 175201-804
Switching voltage range |
V AC |
10 … 230 |
Maximum switching current |
A |
2 |
Maximum switching cycles |
10000 | |
Response tolerance |
K |
± 5 |
Hysteresis range |
K |
2 … 10 |
Maximum temperature change velocity |
K/min |
1 |
For inductive and capacitive loads, protection circuits are to be provided (diode, RC element, varistor).
Assignment to reservoirs
Float switches with min./max. switching points
Tank size DN10 and 20 |
Tank size DN40 and 60 |
1 |
Maximum oil level |
Float switches ABZMS-35-1X/... |
Tank size DN |
Maximum oil volume |
Capacity fluctuation |
Residual volume |
Switching point |
Switching point |
|
P |
R |
L1 |
L2 |
||
l |
l |
mm |
mm |
|||
090F030S-K24 | 10 | 9.6 l; -; - | 3.8 | 5.8 | 90 | 30 |
120F050S-K24 | 20 | 18 l; -; - | 6.8 | 11.2 | 120 | 50 |
165F085S-K24 | 40 | 33 l; -; - | 12.2 | 20.8 | 165 | 85 |
60 | 54 l; -; - | 17 | 37 | 165 | 85 |
Float switches with min. early warning switching points
Tank size DN10 and 20 |
Tank size DN40 and 60 |
1 |
Maximum oil level |
Float switches ABZMS-35-1X/... |
Tank size DN |
Maximum oil volume |
Capacity fluctuation |
Residual volume |
Switching point |
Switching point |
|
P |
R |
L1 |
L2 |
||
l |
l |
mm |
mm |
|||
090F060S-K24 | 10 | 9.6 l; -; - | 2 | 7.6 | 90 | 60 |
120F090S-K24 | 20 | 18 l; -; - | 4 | 14 | 120 | 90 |
165F135S-K24 | 40 | 33 l; -; - | 8 | 25 | 165 | 135 |
60 | 54 l; -; - | 11 | 43 | 165 | 135 |
For applications outside these parameters, please consult us!
With two switching contacts
With two switching contacts and one temperature contact
Dimensions: Float switches with two switching contacts
Plug-in connection M12 x 1, max. 50 VDC
Dimensions in mm
Plug-in connection DIN EN 175301-803, max. 230 VAC
Dimensions in mm
1 |
Mating connector for plug-in connections K24 (M12 x 1), see table "Mating connector" |
2 |
Mating connector for plug-in connections K14, see table "Mating connector" |
3 |
Profile seal M20 x 1.5 RNI 18104 |
4 |
Switching point |
5 |
Connector K24; 4-pole M12 x 1 |
6 |
Connector K14; 4-pole (3 + PE) DIN EN 175301-803 |
7 |
Name plate |
Pinout
Switching function with plug-in connection M12 x 1 |
|
|
|
Switching function with plug-in connection DIN EN 175301-803 |
|
|
|
L1 = |
Normally closed contact at min. |
L2 = |
Normally closed or normally open contact as early warning |
Dimensions: Float switches with two switching contacts and temperature contact
Plug-in connection M12 x 1, max. 50 VDC
Dimensions in mm
Plug-in connection DIN EN 175201-804, max. 230 VAC
Dimensions in mm
1 |
2 x mating connector for plug-in connections K24 (M12 x 1), see table "Mating connector" |
2 |
Mating connector for plug-in connections K6, see table "Mating connector" |
3 |
Profile seal M20 x 1.5 RNI 18104 |
4 |
Switching point |
5 |
2 x connector K24; 4-pole M12 x 1 |
6 |
Connector K6; 7-pole (6 + PE) DIN EN 175201-804 |
7 |
Name plate |
8 |
Temperature contact in sliding tube |
9 |
Temperature contact |
Pinout
Switching function with plug-in connection M12 x 1 |
|
|
|
Switching function with plug-in connection DIN EN 175201-804 |
|
|
|
L1 = |
Normally closed contact at min. |
L2 = |
Normally closed or normally open contact as early warning |
ϑ = |
Normally closed contact at max. temperature |
Installation information
Vertical installation according to technical data (see “Technical data”) Avoid flows Do not expose the switch to heavy impacts and bends Avoid external magnetic fields. Thus, the function of the reed contacts may be impaired.
Electrical connections:
Electrical connections may only be established by specialists Tighten the round connectors M12 x 1 and/or mating connectors after connection Only plug in the round connectors M12 x 1 and/or mating connectors in the de-energized condition Do not overload the contacts (see “Technical data”) In case of inductive load provide a protection circuit!Normative reference
DIN EN 50020
Electric operating equipment for potentially explosive atmospheres - Intrinsic safety “i”; German version EN 50020:2002
DIN EN 60079-0
Electric operating equipment for potentially explosive gas atmospheres - Part 0: General requirements (IEC 60079-0:2004); German version EN 60079-0:2004
DIN EN 60079-14
Electric operating equipment for potentially explosive gas atmospheres - Part 14: Electric systems for endangered areas (except for mining) (IEC 60079-14:2002); German version EN 60079-14:2003
DIN EN 175201-804
Detail specification - Circular connectors - Round contacts, size diameter 1.6 mm, threaded coupling; German version EN 175201-804:1999
DIN EN 175301-803
Detail specification: Rectangular connectors - Flat contacts, 0,8 mm thickness, locking screw not detachable; German version EN 175301-803:1999
Mating connectors
For detailed information see data sheet 08006 |
|||
Mating connector for connector K14 according to DIN EN 175301-803 |
Mating connector for connector K6 according to DIN EN 175201-804 |
||
Denomination |
Part number |
Denomination |
Part number |
LEITUNGSDOSE 4P Z14 M SW SPEZ |
R901017012 |
LEITUNGSDOSE 7P Z6 N6RFFK |
R900002803 |
|
|||
Mating connector for connector K24 |
Mating connector for connector K24 with potted-in PVC cable, 3 m long |
||
Denomination |
Part number |
Denomination |
Part number |
LEITUNGSDOSE 4P Z24 SPEZ |
R900031155 |
LEITUNGSDOSE 4P Z24M12X1+3MSPEZ |
R900064381 |
Mating connectors for mechanical pressure switches with connector “K14”, without circuitry, standard
4P Z14
Mating connectors for mechanical pressure switches with connector “K14”, without circuitry, standard
4P Z14
For mechanical pressure switches with connector “K14”, according to EN 175301-803 and ISO 4400, 3-pole + PE, “large cubic connector”Data sheet
Spare parts & repair
Mating connectors for sensors and valves with connector “K24”, “K35” and “K72”, M12 x 1
4P Z24
Mating connectors for sensors and valves with connector “K24”, “K35” and “K72”, M12 x 1
4P Z24
For sensors and valves with connector “K24”, “K35” and “K72” Mating connectors M12, 4-pole, line cross-section 0.75 mm2Data sheet
Spare parts & repair
Mating connectors for sensors and valves with connector “K24”, “K35” and “K72”, M12 x 1, with assembled connection line
4P Z24 +
Mating connectors for sensors and valves with connector “K24”, “K35” and “K72”, M12 x 1, with assembled connection line
4P Z24 +
For sensors and valves with connector “K24”, “K35” and “K72” Mating connectors M12, 4-pole, line cross-section 0.75 mm2Data sheet
Spare parts & repair
Mating connectors for mechanical position switches, mechanical pressure switches and valves with central connection with connector “K6” and “DK6L”, 6-pole + PE
7P Z6
Mating connectors for mechanical position switches, mechanical pressure switches and valves with central connection with connector “K6” and “DK6L”, 6-pole + PE
7P Z6
Mating connectors for mechanical position switches, mechanical pressure switches and valves with central connection with connector “K6”Data sheet
Spare parts & repair
Use in potentially explosive atmospheres according to Directive 94/9/EC (ATEX)
According to DIN EN 50020 float switches are simple electrical apparatus, which are not provided with voltage sources.
The electrical components consist of reed contacts, bimetal thermostats, plug-in connections and terminals.
The equipment complies with construction regulations according to DIN EN 60079-0 and DIN EN 50020.
According to DIN EN 60079-14 these simple, electrical apparatus may be used in intrinsically safe electric circuits [EEx ib] in systems for equipment class II, category 2G (Zone 1) and category 3G (Zone 2) without marking and certification.
The apparatus are assigned to category ib and temperature class T6.
Intrinsically safe, electrical equipment in potentially explosive atmosphere(zone 1 and 2) |
Associated electrical equipment in safe zone |
|
|
1 |
Cable |
2 |
Isolating relay |