BOSCH REXROTH
R900598388
$1,094.69 USD
- BOSCH REXROTH
- Material:R900598388
- Model:DR20G5-4X/200YMW115
Quantity in stock: 0
The Bosch Rexroth DR20G5-4X/200YMW115 (R900598388) is a sophisticated pressure reducing valve designed for subplate mounting and efficiently controls system pressure by utilizing a pilot-operated mechanism. This valve is particularly characterized by its screw-in cartridge valve and housing, which can be optionally equipped with a check valve. It operates in a default open position, allowing hydraulic fluid to flow from the inlet to the outlet channel freely. The unit's functionality hinges on the main control spool and a spring mechanism that responds to changes in outlet channel pressure. When this pressure surpasses the spring's set value, the pilot poppet is actuated, causing fluid to flow into the spring chamber and prompting the main control spool to maintain constant pressure in the outlet channel. One of the unique features of this model is its external pilot oil return via port Y, which must be considered as it contributes to the set reduced pressure. An optional check valve can be installed for free return flow between channels A and B in subplate mounting version P. The DR20G5-4X/200YMW115 offers various adjustment types for user convenience, including a rotary knob, sleeve with hexagon and protective cap, lockable rotary knob with scale, or rotary knob with scale. This diversity allows for precise control suited to different operational preferences. With its component series X; X maximum operating pressure bar rating, this Bosch Rexroth valve ensures reliable performance under demanding conditions. The porting pattern conforms to ISO standards for threaded connections or as a cartridge valve. The DR20G5-4X/200YMW115 serves as an integral component in hydraulic systems requiring precise pressure regulation and stability.
The pressure valve type DR is a pilot-operated pressure reducing valve. It is used to reduce the system pressure.
It mainly consists of screw-in cartridge valve (cartridge) and housing, optionally with or without check valve (subplate mounting only).
In the rest position the valve is open. The hydraulic fluid is able to flow freely from the inlet channel via the main control spool (1) to the outlet channel. The pressure in the outlet channel is applied to the spring-loaded side of the main control spool (1) via the bore (2). At the same time, the pressure acts upon the side of the main control spool (1) that is opposite to the spring via the bores (3) and (4).
If the pressure in the outlet channel exceeds the value set at the spring (6), the pilot poppet (5) opens.
Hydraulic fluid flows from the spring-loaded side of the main control spool (1) via the nozzle (7) and the pilot poppet (5) into the spring chamber (8).
The main control spool (1) assumes its control position and keeps the value in the outlet channel set at the spring (6) constant. The pilot oil return from the spring chamber (8) is always realized externally via the Y port (9).
In subplate mounting version "P", a check valve (10) can be optionally installed for free return flow from channel A to B.
Type DR 10 -4-4X/…
Type DR 20 G-4-4X/…
Notice!
The pressure in port Y is added 1:1 to the set reduced pressure.
|
01 |
02 |
03 |
04 |
05 |
06 |
07 |
08 |
09 |
10 |
|||
|
DR |
– |
– |
/ |
Y |
* |
|
01 |
Pressure reducing valve |
DR |
|
02 |
Size 10 |
|
|
Subplate mounting "no code" |
10 |
|
|
Threaded connection "G" (G1 1/2) |
10 |
|
|
Size 25 |
||
|
Subplate mounting "no code" |
20 |
|
|
Threaded connection "G" (G3/4) |
15 |
|
|
Threaded connection "G" (G1) |
20 |
|
|
Screw-in cartridge valve "K" |
20 |
|
|
03 |
Subplate mounting |
no code |
|
Threaded connection |
G |
|
|
Cartridge valve |
K |
|
|
Adjustment type |
||
|
04 |
Rotary knob |
4 |
|
Sleeve with hexagon and protective cap |
5 |
|
|
Lockable rotary knob with scale |
6 1) |
|
|
Rotary knob with scale |
7 |
|
|
05 |
Component series 10 ... 19 (10 ... 19: unchanged installation and connection dimensions); (03 = "K") |
1X |
|
Component series 40 ... 49 (40 ... 49: unchanged installation and connection dimensions); (03 = "no code" and "G") |
4X |
|
|
Pressure rating |
||
|
06 |
Set pressure up to 50 bar |
50 |
|
Set pressure up to 100 bar |
100 |
|
|
Set pressure up to 200 bar |
200 |
|
|
Set pressure up to 315 bar |
315 |
|
|
07 |
Internal pilot oil supply, external pilot oil return |
Y |
|
08 |
With check valve (subplate mounting only) |
no code |
|
Without spring return |
M |
|
|
Seal material |
||
|
09 |
NBR seals |
no code |
|
FKM seals |
V |
|
|
Observe compatibility of seals with hydraulic fluid used. (Other seals upon request) |
||
|
10 |
Further details in the plain text |
* |
| 1) H-key with material no. R900008158 is included in the scope of delivery |
Notice! Preferred types and standard units are specified in the EPS (standard price list).
general
|
Size |
10 | 25 | ||
|
Weight |
Subplate mounting |
kg |
3.2 | 3.5 |
|
Cartridge valve |
kg |
2.5 | 2.8 | |
|
Threaded connection |
kg |
3.6 | 3.3 | |
|
Installation position |
any | |||
|
Ambient temperature range |
NBR seals |
°C |
-30 … +80 | |
|
FKM seals |
°C |
-20 … +80 | ||
hydraulic
|
Size |
10 | 25 | ||
|
Nominal pressure |
bar |
315 | ||
|
Maximum operating pressure |
Inlet |
bar |
315 | |
|
Maximum secondary pressure |
Outlet |
bar |
50 100 200 315 |
|
|
Maximum counter pressure |
Port Y |
bar |
250 | |
|
Set pressure |
Minimum |
flow-dependent, see characteristic curves | ||
|
Maximum |
bar |
50 100 200 315 |
||
|
Maximum flow |
Subplate mounting |
l/min |
80 | 160 |
|
Threaded connection |
l/min |
80 | 160 | |
|
Hydraulic fluid |
see table | |||
|
Hydraulic fluid temperature range |
NBR seals |
°C |
-30 … +80 | |
|
FKM seals |
°C |
-20 … +80 | ||
|
Viscosity range |
mm²/s |
10 … 800 | ||
|
Maximum admissible degree of contamination of the hydraulic fluid 1) |
Class 20/18/15 according to ISO 4406 (c) | |||
| 1) | The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter. |
|
Hydraulic fluid |
Classification |
Suitable sealing materials |
Standards |
|
|
Mineral oils |
HL,HLP |
NBR, FKM |
DIN 51524 |
|
|
Bio-degradable |
Insoluble in water |
HETG |
NBR, FKM |
VDMA 24568 |
|
HEES |
FKM |
|||
|
Soluble in water |
HEPG |
FKM |
VDMA 24568 |
|
|
Containing water |
Water-free |
HFDU, HFDR |
FKM |
ISO 12922 |
|
Containing water |
HFC (Fuchs Hydrotherm 46M, Petrofer Ultra Safe 620) |
NBR |
ISO 12922 |
|
|
Important information on hydraulic fluids! For further information and data on the use of other hydraulic fluids, please refer to data sheet 90220 or contact us! There may be limitations regarding the technical valve data (temperature, pressure range, life cycle, maintenance intervals, etc.)! The flash point of the hydraulic fluid used must be 40 K higher than the maximum surface temperature.Flame-resistant – containing water: The maximum pressure differential per control edge is 210 bar. Otherwise, there is increased cavitation erosion. Maximum hydraulic fluid temperature 60 °C Life cycle as compared to operation with mineral oil HLP 30 to 100 % |
||||
For applications outside these parameters, please consult us!
(measured with HLP46, ϑOil = 40 ±5 °C)
Minimum adjustable output pressure P dependent on the flow qV (B to A)
Pilot flow qV st dependent on the flow qV (B to A) and the pressure differential Δp
Δpmin-qV characteristic curve (B to A)
Δp-qV characteristic curve (B to A)
Type DR . .-.-4X/.Y
Subplate mounting
Type DR . .-.-4X/.YM, Type DR . K-.-1X/.YM (screw-in cartridge valve)
Subplate mounting, screw-in cartridge valve
Type DR . G-.-4X/.YM
Threaded connection
Subplate mounting
Dimensions in mm
Subplate mounting
Dimensions in mm
|
1 |
Adjustment type "4" |
|
2 |
Adjustment type "5" |
|
3 |
Adjustment type "6" |
|
4 |
Adjustment type "7" |
|
5 |
Lock nut SW22 |
|
6 |
Hexagon SW10 |
|
7 |
Hexagon SW30, tightening torque for screw-in MA = 50 Nm |
|
8 |
Space required to remove the key |
|
9 |
Locking pin |
|
10 |
Valve mounting bores |
|
11 |
Name plate |
|
12 |
Identical seal rings for ports A and B |
|
13 |
Seal ring for port Y |
|
Type |
L1 |
L2 |
L3 |
L4 |
L5 |
L6 |
B1 |
B2 |
B3 |
B4 |
H1 |
H2 |
H3 |
H4 |
ØD1 |
ØD2 |
ØD3 |
|
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
|
| DR10 | 95.5 | 79 | 42.9 | 23 | 2.5 | 21.5 | 85 | 49 | 66.7 | 7.9 | 71 | 60 | 26 | 26 | 35.5 | 21.8 | 15 |
| DR20 | 96 | 79.5 | 60.3 | 7 | 4 | 39.7 | 100 | 58 | 79.4 | 6.4 | 96 | 78 | 26 | 40 | 41 | 34.8 | 25 |
Threaded connection "G"
Dimensions in mm
|
1 |
Adjustment type "4" |
|
2 |
Adjustment type "5" |
|
3 |
Adjustment type "6" |
|
4 |
Adjustment type "7" |
|
5 |
Lock nut SW22 |
|
6 |
Hexagon SW10 |
|
7 |
Hexagon SW30, tightening torque for screw-in MA = 50 Nm |
|
8 |
Space required to remove the key |
|
10 |
Valve mounting bores |
|
11 |
Name plate |
|
14 |
Y port for pilot oil return |
|
Type |
D1 |
ØD2 |
|
mm |
||
| DR 10G | G1/2 | 34 |
| DR 15G | G3/4 | 42 |
| DR 20G | G1 | 47 |
Notice!
In this valve version, no check valve for free return flow is installed in the valve.
Screw-in cartridge valve "K"
Dimensions in mm
|
1 |
Adjustment type "4" |
|
2 |
Adjustment type "5" |
|
3 |
Adjustment type "6" |
|
4 |
Adjustment type "7" |
|
5 |
Lock nut SW22 |
|
6 |
Hexagon SW10 |
|
7 |
Hexagon SW30, tightening torque for screw-in MA = 50 Nm |
|
8 |
Space required to remove the key |
|
15 |
Seal ring |
|
16 |
Support ring |
Mounting cavity
Dimensions in mm
Notice!
Optionally, the connection bores A, B and Y can be applied at the circumference.
Subplates (separate order)
Size 10:G 460/01 (G3/8)
G 461/01 (G1/2)
Size 25:G 412/01 (G3/4)
G 413/01(G1)
Valve mounting screws (separate order)
Size 10:4 hexagon socket head cap screws ISO 4762 - M10 x 40 - 10.9-flZn-240h-L
(friction coefficient μtotal = 0.09 to 0.14);
Tightening torque MA = 75 Nm ± 10 %
Size 25:4 hexagon socket head cap screws ISO 4762 - M10 x 50 - 10.9-flZn-240h-L
(friction coefficient μtotal = 0.09 to 0.14);
Tightening torque MA = 75 Nm ± 10 %
Notice!
The tightening torques stated are guidelines when using screws with the specified friction coefficients and when using a manual torque wrench (tolerance ± 10 %).