BOSCH REXROTH
R900594126
$943.49 USD
- BOSCH REXROTH
- Material:R900594126
- Model:DR10DP3-4X/25YM
Quantity in stock: 0
The Bosch Rexroth DR10DP3-4X/25YM (R900594126) is a direct-operated pressure reducing valve designed to manage system pressure by limiting the secondary circuit. This valve, suitable for subplate mounting, features a porting pattern in accordance with DIN Form D and ISO standards. It is engineered to maintain a constant level of pressure in channel A, even when external forces are at play, by utilizing its control spool and compression spring mechanism. The DR10DP3-4X/25YM valve operates by allowing hydraulic fluid to flow freely from channel B to channel A in its initial position, while the secondary pressure is set through the adjustment type. The internal control line supplies signal and pilot oil from channel A, ensuring efficient operation. If an increase in pressure occurs due to an actuator's external force effect, the control spool adjusts against the spring to connect channel A to channel TY through the control edge, allowing excess fluid to discharge into the tank and maintaining slight pressure increases. Additionally, this model provides options for leakage oil discharge via channel TY from the spring chamber and includes a check valve for free flow back from channel A to B if needed. Monitoring of secondary pressure is facilitated by a pressure gauge connection. The DR10DP3-4X/25YM offers various adjustment types such as rotary knob, threaded pin with hexagon and protective cap, lockable rotary knob with scale, or rotary knob with scale for versatile applications. In terms of specifications, this model has a size component series X with maximum operating pressures up to bar levels and can handle maximum flow rates measured in liters per minute. The Bosch Rexroth DR10DP3-4X/25YM stands out for its reliability in maintaining system pressures within hydraulic applications while offering user-friendly adjustment features and monitoring capabilities.
The valve type DR 10 DP is a direct operated pressure reducing valve in 3-way version, i. e. with pressure limitation of the secondary circuit.
It is used to limit a system pressure.
The secondary pressure is set via the adjustment type (1).
The valve is open in initial position. Hydraulic fluid can flow from channel B to channel A without restrictions. The pressure in channel A is simultaneously applied via the control line (4) at the piston area opposite the compression spring (3). If the pressure in channel A exceeds the value set at the compression spring (3), the control spool (2) moves to control position and keeps the set pressure in channel A at a constant level.
Signal and pilot oil are supplied internally via the control line (4) from channel A.
If the pressure in channel A increases further due to an external force effect at the actuator, it pushes the control spool (2) even further against the compression spring (3).
In this way, channel A is connected to channel T(Y) via the control edge (5) at the control spool (2). So much hydraulic fluid is discharged into the tank that the pressure can only increase slightly.
The leakage oil discharge from the spring chamber (6) is always effected externally via channel T(Y).
For the free flow back from channel A to channel B, a check valve (7) can optionally be installed.
A pressure gauge connection (8) allows for the control of the secondary pressure.
Type DR 10 DP1-4X/.Y…
|
01 |
02 |
03 |
04 |
05 |
06 |
07 |
08 |
||
|
DR 10 DP |
– |
4X |
/ |
Y |
* |
|
01 |
Pressure reducing valve, direct operated, size 10 |
DR 10 DP |
|
Adjustment type |
||
|
02 |
Rotary knob |
1 |
|
Grub screw with hexagon and protective cap |
2 |
|
|
Lockable rotary knob with scale |
31) |
|
|
Rotary knob with scale |
7 |
|
|
03 |
Component series 40 … 49 (40 … 49: unchanged installation and mounting dimensions) |
4X |
|
04 |
Maximum secondary pressure 25 bar |
25 |
|
Maximum secondary pressure 75 bar |
75 |
|
|
Maximum secondary pressure 150 bar |
150 |
|
|
Maximum secondary pressure 210 bar |
210 |
|
|
05 |
Internal pilot oil supply, external leakage oil discharge |
Y |
|
06 |
With check valve |
no code |
|
Without check valve |
M |
|
|
Seal material |
||
|
07 |
NBR seals |
no code |
|
FKM seals (other seals on request) Attention! Observe compatibility of seals with the hydraulic fluid used! |
V |
|
|
08 |
Further details in the plain text |
* |
1) H-key with material no. R900008158 is included in the scope of delivery.
Preferred types and standard units are contained in the EPS (standard price list).
general
|
Size |
10 | ||
|
Installation position |
any | ||
|
Ambient temperature range |
NBR seals |
°C |
-30 … +50 |
|
FKM seals |
°C |
-20 … +50 | |
|
Weight |
kg |
3 | |
hydraulic
|
Size |
10 | ||
|
Maximum operating pressure |
Port B |
bar |
315 |
|
Maximum secondary pressure |
Port A |
bar |
25 75 150 210 |
|
Maximum counter pressure |
Port T (Y) |
bar |
160 |
|
Maximum flow |
l/min |
80 | |
|
Hydraulic fluid |
see table | ||
|
Hydraulic fluid temperature range |
NBR seals |
°C |
-30 … +80 |
|
FKM seal |
°C |
-20 … +80 | |
|
Viscosity range |
mm²/s |
10 … 800 | |
|
Maximum admissible degree of contamination of the hydraulic fluid 1) |
Class 20/18/15 according to ISO 4406 (c) | ||
| 1) | The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter. |
|
Hydraulic fluid |
Classification |
Suitable sealing materials |
Standards |
|
|
Mineral oils and related hydrocarbons |
HL, HLP, HLPD |
NBR, FKM |
DIN 51524 |
|
|
Environmentally compatible |
Insoluble in water |
HETG |
NBR, FKM |
ISO 15380 |
|
HEES |
FKM |
|||
|
Soluble in water |
HEPG |
FKM |
ISO 15380 |
|
|
Containing water |
Water-free |
HFDU, HFDR |
FKM |
ISO 12922 |
|
Containing water |
HFC (Fuchs Hydrotherm 46M, Petrofer Ultra Safe 620) |
NBR |
ISO 12922 |
|
|
Important information on hydraulic fluids! For further information and data on the use of other hydraulic fluids, please refer to data sheet 90220 or contact us! There may be limitations regarding the technical valve data (temperature, pressure range, life cycle, maintenance intervals, etc.)!Flame-resistant – containing water: Maximum operating pressure 210 bar Maximum hydraulic fluid temperature 60 °C Expected life cycle as compared to HLP hydraulic oil 30 % to 100 % |
||||
For applications outside these parameters, please consult us!
(measured with HLP46, ϑOil = 40 ±5 °C)
pA-qV characteristic curves
Δp-qV characteristic curves
Notice!
The curve development is maintained if the pressure is set lower according to the pressure rating.
The characteristic curves apply to the pressure at the valve output p = 0 bar across the entire flow range.
Version "M"
Without check valve
Version "no code"
With check valve
Dimensions in mm
|
1 |
Name plate |
|
2 |
Adjustment type "1" |
|
3 |
Adjustment type "2" |
|
4 |
Adjustment type "3" |
|
5 |
Adjustment type "7" |
|
6 |
Space required to remove the key |
|
7 |
Valve mounting bores |
|
8 |
Lock nut SW24 |
|
9 |
Hexagon SW10 |
|
10 |
Identical seal rings for ports A, B, P, T (Y) |
|
11 |
Pressure gauge connection G1/4; 12 mm deep; internal hexagon SW6 |
|
12 |
Locking pin |
|
13 |
Porting pattern according to DIN 24340 form D and ISO 5781-06-07-0-00 |
Subplates (separate order)
G 460/01 (G3/8)
G 461/01 (G1/2)
Valve mounting screws (separate order)
4 metric hexagon socket head cap screws
ISO 4762 - M10 x 60 - 10.9-flZn-240h-L
with friction coefficient μtotal = 0.09 to 0.14,
tightening torque MA = 60 Nm ± 10%,
material no. R912000116