BOSCH REXROTH
R106585040
$345.57 USD
- BOSCH REXROTH
- Material:R106585040
- Model:LSG-B-50-DD
Quantity in stock: 0
The Bosch Rexroth LINEAR-SET LSG-B-50-DD (R106585040) is a high-quality linear set designed for precision motion applications. This robust assembly features a closed steel configuration with integrated wiper seals, ensuring reliable operation by preventing the ingress of contaminants. The linear set is constructed from lamellar graphite cast iron and includes the super LB B linear bushing, which is known for its high load capacities and precise movement. With a shaft diameter of 50mm, this model provides sturdy support for linear motion tasks without the need for self-alignment features. The standard precision housing contributes to the overall rigidity and performance of the system. This LINEAR-SET is especially suitable for applications requiring controlled friction force (FR), as it maintains consistent frictional drags even when not under radial load, with values dependent on speed and lubrication conditions. The dynamic load capacity (C) of this model accounts for the main direction of loading; however, if loads are applied in non-primary directions, the capacity must be adjusted using specified factors. It can handle maximum accelerations (amax) efficiently and operates within an ambient temperature range of -20°C to 80°C without compromising performance. This LINEAR-SET has a substantial outer diameter that facilitates a breakaway force tailored to meet demanding operational requirements. Additionally, it boasts an impressive static load rating (C), ensuring stability and longevity under constant loads. With its size V series designation and lack of self-alignment feature, this Bosch Rexroth product excels in applications where precision alignment is managed externally or inherently within the system design. The weight specifications indicate that it is robust yet manageable for various installations. Overall, the Bosch Rexroth LINEAR-SET LSG-B-50-DD is tailored for users seeking a reliable and precise linear motion solution that balances performance with durability in challenging industrial settings.
Linear set (steel), B-50, with two seals
Linear set (steel)
Closed
With super LB B
Shaft diameter d = 50
With two seals
Version: Standard
Unpacked Weight: 3.188 kg
For precision guides with easy installation. Fixed working bore diameter.
| Precision housing (lamellar graphite cast iron/steel) |
| super linear bushing B without self-alignment feature |
| Integrated wiper seals |
| Data Sheet | Download Data Sheet |
| 2D CAD | Download 2D CAD |
| 2D CAD | Download 2D CAD |
| 3D CAD | Download 3D CAD |
| 3D CAD | Download 3D CAD |
| Manual | Download Manual |
| Manual | Download Manual |
| Manual | Download Manual |
| Manual | Download Manual |
| Manual | Download Manual |
| Size V | 14 |
| Series | Super B (no self-alignment feature) |
| Footnote friction force FR | Frictional drags generated by linear bushings with integrated wiper seals on two sides when not under radial load. The frictional drags depend on speed and lubrication. |
| Size B1 (linear bushing) | 72 |
| Size E1 | 108 |
| Footnote dynamic load capacity C | The load capacities apply for the main direction of loading. If the direction of loading is not the main direction of loading, the load capacities must be multiplied by the following factors: Ø d 12 and 16: f = 0.82, f0 = 0.86, Ø d 20 to 50: f = 0.82, f0 = 0.78 |
| Size H | 50 |
| Max. acceleration amax | 150 |
| Permissible ambient temperature | -10 °C ... +80 °C |
| Outer diameter D | 75 |
| Breakaway force | 10 |
| Maximum permissible linear speed vmax | 3 |
| Size D | 75 |
| Footnote static load capacity C0 | The load capacities apply for the main direction of loading. If the direction of loading is not the main direction of loading, the load capacities must be multiplied by the following factors: Ø d 12 and 16: f = 0.82, f0 = 0.86, Ø d 20 to 50: f = 0.82, f0 = 0.78 |
| Static load rating C0 | 8280 |
| Friction force | 4 |
| Size A | 130 |
| Productgroup ID | 17 |
| Permissible ambient temperature (max) | |
| Size E2 | 50 |
| Size SW | 8 |
| Permissible ambient temperature (min) | |
| Size S | 9 |
| Size A1 | 57 |
| Shaft diameter d | 50 |
| Linear guide type | Linear bushing and shaft |
| Filter for linear bushings and shafts | Linear sets with linear bushings |
| Format of linear bushings | – Closed |
| Dynamic load capacity C | 14730 |
| Size L | 100 |
| Footnote size H1 | Tolerance ISO 8062-3 - DCTG 9. |
| Size B | 70 |
| Weight | 3.188 |
| Size D1 with tolerance | |
| Size H1 | 105 |
General technical data
|
Ø d |
mm |
12 | 16 | 20 | 25 | 30 | 40 | 50 |
|
m |
kg |
0.15 | 0.24 | 0.42 | 0.83 | 1.22 | 2.29 | 3.23 |
|
FR 1) |
N |
0.8 | 1 | 1.5 | 2 | 2.5 | 3 | 4 |
|
Breakaway force |
N |
1.5 | 2 | 3 | 4.5 | 6 | 8 | 10 |
|
Shaft radial clearance h6 |
µm |
+ 38 + 10 |
+ 43 + 11 |
+ 50 + 12 |
||||
|
Operating conditions |
||||||||
|
Permissible ambient temperature (min ... max) |
-10 °C ... +80 °C | |||||||
| 1) | Frictional drags generated by Linear Bushings with integrated wiper seals on two sides when not under radial load. The frictional drags depend on speed and lubrication. |
Load capacities and load moments
|
Ød |
mm |
12 | 16 | 20 | 25 | 30 | 40 | 50 |
|
C 1) |
N |
1020 | 1500 | 2470 | 5040 | 5860 | 10070 | 14730 |
|
C0 1) |
N |
490 | 830 | 1340 | 2470 | 3570 | 5570 | 8280 |
| 1) | The load ratings apply for the main direction of loading. If the load direction is not the main direction of loading, the dynamic load ratings must be multiplied by the following factors:Ø d 12 and 16: f = 0.82, f0 = 0.86,Ø d 20 to 50: f = 0.82, f0 = 0.78 |
| The load ratings are based on a total travel of 100, 00 m. When based on 50 000 m, the values in the table need to be multiplied by 1.26. |
Legend
|
Symbol |
Description |
Unit |
|
Ød |
Shaft diameters |
mm |
|
amax |
Maximum acceleration travel |
m/s2 |
|
C |
Dynamic load capacity |
N |
|
C0 |
Static load capacity |
N |
|
FR |
Friction force |
N |
|
m |
Mass |
kg |
|
vmax |
Maximum permissible speed |
m/s |
Impact of load direction on load rating of closed Linear Bushings
The listed load ratings should be chosen depending on installation in minimum or maximum position and should be based on the calculations. If the load direction is clearly defined and the Linear Bushings can be installed in maximum position, the load ratings Cmax. (dynamic load rating) and C0 max (static load rating) can be used. If aligned installation is not possible or the load direction is not defined, the minimum load ratings must be used.
Reduced load capacity with short stroke
In case of short stroke, the service life of the shaft is less than that of the super Linear Bushing. The load ratings C specified in the tables must therefore be multiplied by the factor f.s .
| 1) | fs = factor |
| 2) | s = movement path |
Definition of dynamic load ratings
Dimensions
|
Ød |
mm |
12 | 16 | 20 | 25 | 30 | 40 | 50 |
|
D |
mm |
22 | 26 | 32 | 40 | 47 | 62 | 75 |
|
A 1) |
mm |
42 | 50 | 60 | 74 | 84 | 108 | 130 |
|
A1 1) |
mm |
21 | 26 | 28 | 38 | 41 | 51 | 57 |
|
B |
mm |
32 1) | 35 1) | 42 1) | 54 1) | 60 1) | 78 1) | 70 1) |
|
B1 |
mm |
20 | 22 | 28 | 40 | 48 | 56 | 72 |
|
E1 |
32 mm ±0.15 | 40 mm ±0.15 | 45 mm ±0.15 | 60 mm ±0.15 | 68 mm ±0.2 | 86 mm ±0.2 | 108 mm ±0.2 | |
|
E2 |
23 mm ±0.15 | 26 mm ±0.15 | 32 mm ±0.15 | 40 mm ±0.15 | 45 mm ±0.2 | 58 mm ±0.2 | 50 mm ±0.2 | |
|
H |
mm |
18 | 22 | 25 | 30 | 35 | 45 | 50 |
|
Tolerance for H 2) |
µm |
+ 8 - 16 |
+ 13 - 21 |
|||||
|
H1 1) |
mm |
35 | 42 | 50 | 60 | 70 | 90 | 105 |
|
L |
mm |
32 | 36 | 45 | 58 | 68 | 80 | 100 |
|
S |
mm |
4.5 | 5.5 | 6.6 | 9 | |||
|
SW |
mm |
2.5 | 3 | 5 | 6 | 8 | ||
|
V 1) |
mm |
5.5 | 6.5 | 8 | 9 | 10 | 12 | 14 |
| 1) | Tolerance ISO 8062-3 - DCTG 9. |
| 2) | Clamped (fastened) in relation to Ø d. |
Radial clearance
The radial clearance values shown in the table have been determined from statistics and correspond to values expected in practice. The adjustable Linear Sets come clamped to an h5 shaft (lower limit) and set to zero clearance.
Vertical dimension
The tolerance values for the vertical dimension "H" for the Linear Sets shown in the table have been determined from statistics and correspond to values expected in practice.
Bolts
We recommend bolts in accordance with ISO 4762-8.8 for fastening the Linear Sets.
Lubrication
On-shaft relubrication on relubricatable Linear Bushing only until lubricant seeps out.
General mounting instructions
Wiper seals for closed-type Super Linear Bushings and Standard Linear Bushings
Wiper seals for closed-type Super Linear Bushings and Standard Linear Bushings
Galvanized metal case Elastomer wiper sealCatalog
Instructions
Service
CAD data
Metal cases for Super Linear Bushings and standard Linear Bushings
Metal cases for Super Linear Bushings and standard Linear Bushings
Galvanized steelCatalog
Instructions
Service
CAD data