***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Bosch Rexroth directly.***
The Bosch Rexroth LINEAR-SET LSG-B-12-DD (R106581240) is a high-quality linear motion set designed for precision applications. This set includes a closed linear bushing of the Super B series without a self-alignment feature, ensuring stable and accurate movement. The product is crafted from durable steel with an outer diameter D and features an integrated wiper seal on both sides to protect against contaminants while maintaining low frictional drags, which are dependent on speed and lubrication conditions. The LINEAR-SET LSG-B-12-DD boasts a standard precision housing made from lamellar graphite cast ironsteel, providing robust support for the super linear bushing B. It has been engineered for fixed working bore diameters with shaft diameter d, suitable for various industrial applications where precision is key. The set operates efficiently within a permissible ambient temperature range of -20°C to 80°C, accommodating a wide range of operating environments. Dynamic load capacity C and static load rating C are indicative of the product's ability to withstand forces during operation. These capacities are given for the main direction of loading; however, they must be adjusted by specific factors if the direction of loading varies. The LINEAR-SET can handle maximum accelerations (amax) gracefully and is capable of achieving a breakaway force of 0.5 N without radial load. This Bosch Rexroth linear set is designed with size E dimensions, and it weighs 0.3 kg, making it suitable for various installation spaces while ensuring ease of integration into machinery or equipment setups. The product group ID further classifies it as part of Bosch Rexroth's comprehensive offerings in linear motion technology. Overall, the LINEAR-SET LSG-B-12-DD is tailored for users requiring precise linear guidance systems that combine durability with performance in demanding industrial settings or sophisticated mechanical assemblies.


Linear set (steel), B-12, with two seals

Linear set (steel)
Closed
With super LB B
Shaft diameter d = 12
With two seals
Version: Standard

Unpacked Weight: 0.154 kg

For precision guides with easy installation. Fixed working bore diameter.

Precision housing (lamellar graphite cast iron/steel)
super linear bushing B without self-alignment feature
Integrated wiper seals
Size V5.5
SeriesSuper B (no self-alignment feature)
Footnote friction force FRFrictional drags generated by linear bushings with integrated wiper seals on two sides when not under radial load. The frictional drags depend on speed and lubrication.
Size B1 (linear bushing)20
Size E132
Footnote dynamic load capacity CThe load capacities apply for the main direction of loading. If the direction of loading is not the main direction of loading, the load capacities must be multiplied by the following factors: Ø d 12 and 16: f = 0.82, f0 = 0.86, Ø d 20 to 50: f = 0.82, f0 = 0.78
Size H18
Max. acceleration amax150
Permissible ambient temperature-10 °C ... +80 °C
Outer diameter D22
Breakaway force1.5
Maximum permissible linear speed vmax3
Size D22
Footnote static load capacity C0The load capacities apply for the main direction of loading. If the direction of loading is not the main direction of loading, the load capacities must be multiplied by the following factors: Ø d 12 and 16: f = 0.82, f0 = 0.86, Ø d 20 to 50: f = 0.82, f0 = 0.78
Static load rating C0490
Friction force0.8
Size A42
Productgroup ID17
Permissible ambient temperature (max)+80
Size E223
Size SW2.5
Permissible ambient temperature (min)-10
Size S4.5
Size A121
Shaft diameter d12
Linear guide typeLinear bushing and shaft
Filter for linear bushings and shaftsLinear sets with linear bushings
Format of linear bushings– Closed
Dynamic load capacity C1020
Size L32
Footnote size H1Tolerance ISO 8062-3 - DCTG 9.
Size B32
Weight0.154
Size D1 with tolerance
Size H135

General technical data

Ø d

mm

12 16 20 25 30 40 50

m

kg

0.15 0.24 0.42 0.83 1.22 2.29 3.23

FR 1)

N

0.8 1 1.5 2 2.5 3 4

Breakaway force

N

1.5 2 3 4.5 6 8 10

Shaft radial clearance h6

µm

+ 38
+ 10
+ 43
+ 11
+ 50
+ 12

Operating conditions

Permissible ambient temperature (min ... max)

-10 °C ... +80 °C
1) Frictional drags generated by Linear Bushings with integrated wiper seals on two sides when not under radial load. The frictional drags depend on speed and lubrication.

Load capacities and load moments

Ød

mm

12 16 20 25 30 40 50

C 1)

N

1020 1500 2470 5040 5860 10070 14730

C0 1)

N

490 830 1340 2470 3570 5570 8280
1) The load ratings apply for the main direction of loading. If the load direction is not the main direction of loading, the dynamic load ratings must be multiplied by the following factors:Ø d 12 and 16: f = 0.82, f0 = 0.86,Ø d 20 to 50:  f = 0.82, f0 = 0.78
The load ratings are based on a total travel of 100, 00 m. When based on 50 000 m, the  values in the table need to be multiplied by 1.26.

Legend

Symbol

Description

Unit

Ød

Shaft diameters

mm

amax

Maximum acceleration travel

m/s2

C

Dynamic load capacity

N

C0

Static load capacity

N

FR

Friction force

N

m

Mass

kg

vmax

Maximum permissible speed

m/s

Impact of load direction on load rating of closed Linear Bushings

The listed load ratings should be chosen depending on installation in minimum or maximum position and should be based on the calculations. If the load direction is clearly defined and the Linear Bushings can be installed in maximum position, the load ratings Cmax. (dynamic load rating) and C0 max (static load rating) can be used. If aligned installation is not possible or the load direction is not defined, the minimum load ratings must be used.

 

technical illustration-R106581240-Linear set (steel), B-12, with two seals

Reduced load capacity with short stroke

In case of short stroke, the service life of the shaft is less than that of the super Linear Bushing. The load ratings C specified in the tables must therefore be multiplied by the factor f.s .

technical illustration-R106581240-Linear set (steel), B-12, with two seals
1) fs = factor
2) s = movement path

Definition of dynamic load ratings

technical illustration-R106581240-Linear set (steel), B-12, with two seals

Dimensions

Ød

mm

12 16 20 25 30 40 50

D

mm

22 26 32 40 47 62 75

A 1)

mm

42 50 60 74 84 108 130

A1 1)

mm

21 26 28 38 41 51 57

B

mm

32 1) 35 1) 42 1) 54 1) 60 1) 78 1) 70 1)

B1

mm

20 22 28 40 48 56 72

E1

32 mm ±0.15 40 mm ±0.15 45 mm ±0.15 60 mm ±0.15 68 mm ±0.2 86 mm ±0.2 108 mm ±0.2

E2

23 mm ±0.15 26 mm ±0.15 32 mm ±0.15 40 mm ±0.15 45 mm ±0.2 58 mm ±0.2 50 mm ±0.2

H

mm

18 22 25 30 35 45 50

Tolerance for H 2)

µm

+ 8
- 16
+ 13
- 21

H1 1)

mm

35 42 50 60 70 90 105

L

mm

32 36 45 58 68 80 100

S

mm

4.5 5.5 6.6 9

SW

mm

2.5 3 5 6 8

V 1)

mm

5.5 6.5 8 9 10 12 14
1) Tolerance ISO 8062-3 - DCTG 9.
2) Clamped (fastened) in relation to Ø d.

Life expectancy calculation

Radial clearance

The radial clearance values shown in the table have been determined from statistics and correspond to values expected in practice. The adjustable Linear Sets come clamped to an h5 shaft (lower limit) and set to zero clearance.

 

Vertical dimension

The tolerance values for the vertical dimension "H" for the Linear Sets shown in the table have been determined from statistics and correspond to values expected in practice.

 

Bolts

We recommend bolts in accordance with ISO 4762-8.8 for fastening the Linear Sets.

 

Lubrication

technical illustration-R106581240-Linear set (steel), B-12, with two seals

On-shaft relubrication on relubricatable Linear Bushing only until lubricant seeps out.

General mounting instructions

Lubrication

Directives and standards

Notes