BOSCH REXROTH
R106563040
$149.30 USD
- BOSCH REXROTH
- Material:R106563040
- Model:LSG-A-30-DD
Quantity in stock: 0
The Bosch Rexroth LINEAR-SET LSG-A-30-DD (R106563040) is a high-quality linear set designed for precision guiding applications requiring easy installation and reliable operation. This set includes a closed steel linear bushing of the Super A series, featuring self-alignment capabilities and integrated wiper seals that maintain cleanliness by preventing contaminants from entering the system. The bushing's shaft diameter 'd' ensures compatibility with standardized components, while the dual-seal design enhances the product's durability and performance. The linear set is crafted from lamellar graphite cast iron steel, providing a robust and stable platform for linear motion. It boasts standard precision housing, making it suitable for various industrial applications. The dynamic load capacity 'C' indicates the unit's ability to handle significant loads in its main direction of operation. In cases where loading occurs in other directions, load capacities can be adjusted using specified factors to ensure optimal performance. Equipped with a maximum acceleration 'amax' and capable of operating within an ambient temperature range of -20°C to +80°C, this linear set is versatile for different working environments. The outer diameter 'D', breakaway force, and maximum permissible linear speed 'vmax' are engineered to meet rigorous operational demands, allowing speeds up to 5 m/s with certain limitations on service life due to wear on plastic parts. The LINEAR-SET LSG-A-30-DD also comes with an impressive static load rating 'C', ensuring it can withstand substantial stationary forces without compromising integrity. Its weight is finely balanced at 2.7 kg, which contributes to its efficiency and ease of handling during installation or maintenance procedures. Overall, this product provides a reliable solution for applications requiring precise linear motion control with minimal frictional resistance and maximum longevity under varied environmental conditions.
Linear set (steel), A-30, with two seals
Linear set (steel)
Closed
With super LB A
Shaft diameter d = 30
With two seals
Version: Standard
Unpacked Weight: 1.255 kg
For precision guides with easy installation. Fixed working bore diameter.
| Precision housing (lamellar graphite cast iron/steel) |
| super linear bushing A with self-alignment feature |
| Integrated wiper seals |
| Data Sheet | Download Data Sheet |
| 2D CAD | Download 2D CAD |
| 2D CAD | Download 2D CAD |
| 3D CAD | Download 3D CAD |
| 3D CAD | Download 3D CAD |
| Manual | Download Manual |
| Manual | Download Manual |
| Manual | Download Manual |
| Manual | Download Manual |
| Manual | Download Manual |
| Size V | 10 |
| Series | Super A (with self-alignment feature) |
| Footnote friction force FR | Frictional drags generated by linear bushings with integrated wiper seals on two sides when not under radial load. The frictional drags depend on speed and lubrication. |
| Size B1 (linear bushing) | 48 |
| Size E1 | 68 |
| Footnote dynamic load capacity C | The load capacities apply for the main direction of loading. If the direction of loading is not the main direction of loading, the load capacities must be multiplied by the following factors: Ø d 12 and 16: f = 0.82, f0 = 0.86, Ø d 20 to 50: f = 0.82, f0 = 0.78 |
| Size H | 35 |
| Max. acceleration amax | 150 |
| Permissible ambient temperature | -10 °C ... +80 °C |
| Outer diameter D | 47 |
| Breakaway force | 6 |
| Maximum permissible linear speed vmax | 3 |
| Size D | 47 |
| Footnote static load capacity C0 | The load capacities apply for the main direction of loading. If the direction of loading is not the main direction of loading, the load capacities must be multiplied by the following factors: Ø d 12 and 16: f = 0.82, f0 = 0.86, Ø d 20 to 50: f = 0.82, f0 = 0.78 |
| Static load rating C0 | 3570 |
| Note: Maximum permissible speed vmax | Speeds of up to 5 m/s possible. Service life is limited by heightened wear to plastic parts. Tests have shown total travel from 50 • 105 m to 100 • 105 m without failure. |
| Friction force | 2.5 |
| Size A | 84 |
| Productgroup ID | 17 |
| Permissible ambient temperature (max) | |
| Size E2 | 45 |
| Size SW | 5 |
| Permissible ambient temperature (min) | |
| Size S | 6.6 |
| Size A1 | 41 |
| Shaft diameter d | 30 |
| Linear guide type | Linear bushing and shaft |
| Filter for linear bushings and shafts | Linear sets with linear bushings |
| Format of linear bushings | – Closed |
| Dynamic load capacity C | 5860 |
| Size L | 68 |
| Footnote size H1 | Tolerance ISO 8062-3 - DCTG 9. |
| Size B | 60 |
| Weight | 1.255 |
| Size D1 with tolerance | |
| Size H1 | 70 |
General technical data
|
Ø d |
mm |
12 | 16 | 20 | 25 | 30 | 40 | 50 |
|
amax |
m/s² |
150 | ||||||
|
vmax 1) |
m/s |
3 | ||||||
|
m |
kg |
0.15 | 0.24 | 0.42 | 0.83 | 1.22 | 2.29 | 3.23 |
|
FR 2) |
N |
0.8 | 1 | 1.5 | 2 | 2.5 | 3 | 4 |
|
Breakaway force |
N |
1.5 | 2 | 3 | 4.5 | 6 | 8 | 10 |
|
Shaft radial clearance h6 |
µm |
+ 38 + 10 |
+ 43 + 11 |
+ 50 + 12 |
||||
|
Operating conditions |
||||||||
|
Permissible ambient temperature (min ... max) |
-10 °C ... +80 °C | |||||||
| 1) | Speeds of up to 5 m/s possible. Service life is limited by heightened wear to plastic parts. Tests have shown total travel from 50 • 105 m to 100 • 105 m without failure. |
| 2) | Frictional drags generated by Linear Bushings with integrated wiper seals on two sides when not under radial load. The frictional drags depend on speed and lubrication. |
Load capacities and load moments
|
Ød |
mm |
12 | 16 | 20 | 25 | 30 | 40 | 50 |
|
C 1) |
N |
1020 | 1500 | 2470 | 5040 | 5860 | 10070 | 14730 |
|
C0 1) |
N |
490 | 830 | 1340 | 2470 | 3570 | 5570 | 8280 |
| 1) | The load ratings apply for the main direction of loading. If the load direction is not the main direction of loading, the dynamic load ratings must be multiplied by the following factors:Ø d 12 and 16: f = 0.82, f0 = 0.86,Ø d 20 to 50: f = 0.82, f0 = 0.78 |
| The load ratings are based on a total travel of 100, 00 m. When based on 50 000 m, the values in the table need to be multiplied by 1.26. |
Legend
|
Symbol |
Description |
Unit |
|
Ød |
Shaft diameters |
mm |
|
amax |
Maximum acceleration travel |
m/s2 |
|
C |
Dynamic load capacity |
N |
|
C0 |
Static load capacity |
N |
|
FR |
Friction force |
N |
|
m |
Mass |
kg |
|
vmax |
Maximum permissible speed |
m/s |
Impact of load direction on load rating of closed Linear Bushings
The listed load ratings should be chosen depending on installation in minimum or maximum position and should be based on the calculations. If the load direction is clearly defined and the Linear Bushings can be installed in maximum position, the load ratings Cmax. (dynamic load rating) and C0 max (static load rating) can be used. If aligned installation is not possible or the load direction is not defined, the minimum load ratings must be used.
Reduced load capacity with short stroke
In case of short stroke, the service life of the shaft is less than that of the super Linear Bushing. The load ratings C specified in the tables must therefore be multiplied by the factor f.s .
| 1) | fs = factor |
| 2) | s = movement path |
Reduced load capacity with high load
If the load F on a Super Linear Bushing A is more than F > 0.5 x C, the dynamic load rating C decreases.
Definition of dynamic load ratings
Self-alignment feature
The self-alignment feature in the steel bearing plates and machined ball guide grooves ensure quieter travel. The flow chart shows a comparison with a conventional Linear Bushing. The example is based on a load of 800 N and misalignment of about 8 ft (caused by shaft deflection).
Due to the self-alignment feature, two super Linear Bushings must be used on at least one of the shafts in the guide.
| FR = Frictional drag | |
| s = travel distance | |
| v = travel speed | |
| a) | Super Linear Bushing, A Ød 20 |
| b) | Conventional Linear Bushing, Ød 20 |
Dimensions
|
Ød |
mm |
12 | 16 | 20 | 25 | 30 | 40 | 50 |
|
D |
mm |
22 | 26 | 32 | 40 | 47 | 62 | 75 |
|
A 1) |
mm |
42 | 50 | 60 | 74 | 84 | 108 | 130 |
|
A1 1) |
mm |
21 | 26 | 28 | 38 | 41 | 51 | 57 |
|
B |
mm |
32 1) | 35 1) | 42 1) | 54 1) | 60 1) | 78 1) | 70 1) |
|
B1 1) |
mm |
20 | 22 | 28 | 40 | 48 | 56 | 72 |
|
E1 |
32 mm ±0.15 | 40 mm ±0.15 | 45 mm ±0.15 | 60 mm ±0.15 | 68 mm ±0.2 | 86 mm ±0.2 | 108 mm ±0.2 | |
|
E2 |
23 mm ±0.15 | 26 mm ±0.15 | 32 mm ±0.15 | 40 mm ±0.15 | 45 mm ±0.2 | 58 mm ±0.2 | 50 mm ±0.2 | |
|
H |
mm |
18 | 22 | 25 | 30 | 35 | 45 | 50 |
|
Tolerance for H 2) |
µm |
+ 8 - 16 |
+ 13 - 21 |
|||||
|
H1 1) |
mm |
35 | 42 | 50 | 60 | 70 | 90 | 105 |
|
L |
mm |
32 | 36 | 45 | 58 | 68 | 80 | 100 |
|
S |
mm |
4.5 | 5.5 | 6.6 | 9 | |||
|
SW |
mm |
2.5 | 3 | 5 | 6 | 8 | ||
|
V 1) |
mm |
5.5 | 6.5 | 8 | 9 | 10 | 12 | 14 |
| 1) | Tolerance ISO 8062-3 - DCTG 9. |
| 2) | Clamped (fastened) in relation to Ø d. |
Radial clearance
The radial clearance values shown in the table have been determined from statistics and correspond to values expected in practice. The adjustable Linear Sets come clamped to an h5 shaft (lower limit) and set to zero clearance.
Vertical dimension
The tolerance values for the vertical dimension "H" for the Linear Sets shown in the table have been determined from statistics and correspond to values expected in practice.
Bolts
We recommend bolts in accordance with ISO 4762-8.8 for fastening the Linear Sets.
Lubrication
On-shaft relubrication on relubricatable Linear Bushing only until lubricant seeps out.
General mounting instructions
Wiper seals for closed-type Super Linear Bushings and Standard Linear Bushings
Wiper seals for closed-type Super Linear Bushings and Standard Linear Bushings
Galvanized metal case Elastomer wiper sealCatalog
Instructions
Service
CAD data
Metal cases for Super Linear Bushings and standard Linear Bushings
Metal cases for Super Linear Bushings and standard Linear Bushings
Galvanized steelCatalog
Instructions
Service
CAD data