***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Bosch Rexroth directly.***
The Bosch Rexroth LINEAR-SET LSACT-50-DD-NR-G (R102925034) is a high-quality linear motion set designed for precision applications. This product features a lightweight tandem housing made from aluminum, incorporating two compact linear bushings with the model code KBCNR. The shaft diameter is meticulously crafted to ensure smooth motion and the entire unit comes with integrated wiper seals to protect against contaminants, enhancing the longevity of the system. Equipped with two seals and possessing rust-resistant properties, this linear set is pre-greased with Dynalub, reducing maintenance requirements and ensuring reliable operation right from installation. It exhibits normal radial clearance and is built to withstand dynamic loads effectively, as indicated by its robust dynamic load capacity. The LSACT-50-DD-NR-G is capable of handling maximum accelerations and operates within a permissible ambient temperature range that ensures functionality in various working environments. With its closed format of linear bushings, it maintains a compact footprint while delivering exceptional performance. The outer diameter of the unit is designed to provide stability and support for the load capacities which are optimized for the main direction of loading. Any deviation from this direction requires adjustment of these capacities using specified factors provided in the product documentation. This linear set can achieve a significant breakaway force and supports a maximum permissible linear speed without compromising on its static load rating. The friction force remains consistently low thanks to the efficient design, contributing to smooth operation under various conditions. Overall, the Bosch Rexroth LINEAR-SET LSACT-50-DD-NR-G stands out for its combination of durability, precision capabilities, and ease of use in applications requiring reliable linear motion solutions. Its construction ensures that it can be integrated into systems where high performance and longevity are critical.


Linear set (aluminum), CT-50, with two seals, CR, greased

Linear set (aluminum)
With compact LB, tandem, closed
Shaft diameter d = 50
With two seals
Version: Rust-resistant
Greased

Unpacked Weight: 2.443 kg
Lightweight precision tandem housing (aluminum)
Two compact linear bushings KBC-NR
Integrated wiper seals
Normal radial clearance
Initial lubrication with Dynalub 510
SeriesCompact
Footnote friction force FRFrictional drags generated by linear bushings with integrated wiper seals on two sides when not under radial load. The frictional drags depend on speed and lubrication.
Size E182
Footnote dynamic load capacity CThe load capacities apply for the main direction of loading. If the load direction is not the main direction of loading, the load capacities must be multiplied by the following factors: ↩Ø d 12 and 16: f = 0.90, f0 = 0.86, ↩Ø d 20 to 50: f = 0.79, f0 = 0.68
Size H47
Max. acceleration amax150
Permissible ambient temperature-10 °C ... +80 °C
Outer diameter D62
Breakaway force10
Size H430
Maximum permissible linear speed vmax5
Size D62
Footnote static load capacity C0The load capacities apply for the main direction of loading. If the load direction is not the main direction of loading, the load capacities must be multiplied by the following factors: ↩Ø d 12 and 16: f = 0.90, f0 = 0.86, ↩Ø d 20 to 50: f = 0.79, f0 = 0.68
Size N146
Static load rating C08560
Friction force4
Size A103
Productgroup ID17
Size N226
Permissible ambient temperature (max)+80
Size E2100
Permissible ambient temperature (min)-10
Size S10.5
Shaft diameter d50
Linear guide typeLinear bushing and shaft
Filter for linear bushings and shaftsLinear sets with linear bushings
Format of linear bushings– Closed
Dynamic load capacity C8170
Static longitudinal moment load capacity ML0271
Size L145
Weight2.443
Size D1 with tolerance
Size H192

General technical data

Ø d

mm

12 16 20 25 30 40 50

amax

m/s²

150

vmax

m/s

5

m

kg

0.17 0.24 0.31 0.57 0.8 1.54 2.45

FR 1)

N

0.8 1 1.5 2 2.5 3 4

Breakaway force

N

1.5 2 3 4.5 6 8 10

Shaft radial clearance h6

µm

+ 32
0
+ 33
- 1
+ 36
0
+ 42
- 1

Operating conditions

Permissible ambient temperature (min ... max)

-10 °C ... +80 °C
1) Frictional drags generated by Linear Bushings with integrated wiper seals on two sides when not under radial load. The frictional drags depend on speed and lubrication.

Load capacities and load moments

Ød

mm

12 16 20 25 30 40 50

C 1)

N

920 1180 1610 3330 4385 7260 8170

C0 1)

N

780 920 1440 3120 4460 7440 8560

ML0

Nm

13 18 21 59 103 204 271
1) The load ratings apply for the main direction of loading. If the load direction is not the main direction of loading, the load ratings must be multiplied by the following factors: Ø d 12 and 16: f = 0,90, f0 = 0.86, Ø d 20 to 50: f = 0.79, f0 = 0.68
The load ratings are based on a total travel of 100, 00 m. When based on 50 000 m, the  values in the table need to be multiplied by 1.26.

Legend

Symbol

Description

Unit

Ød

Shaft diameters

mm

amax

Maximum acceleration travel

m/s2

C

Dynamic load capacity

N

C0

Static load capacity

N

FR

Friction force

N

m

Mass

kg

ML0

Static longitudinal moment load capacity

Nm

vmax

Maximum permissible speed

m/s2

Effect of load direction on load rating

The listed load ratings should be chosen depending on installation in minimum or maximum position and should be based on the calculations. If the load direction is clearly defined and the Linear Bushings can be installed in maximum position, the load ratings Cmax. (dynamic load rating) and C0 max (static load rating) can be used. If aligned installation is not possible or the load direction is not defined, the minimum load ratings must be used.

 

technical illustration-R102925034-Linear set (aluminum), CT-50, with two seals, CR, greased

Reduced load capacity with short stroke

In case of short stroke, the service life of the shafts is less than that of Linear Bushings. The load ratings C specified in the tables must therefore be multiplied by the factor f.s .

technical illustration-R102925034-Linear set (aluminum), CT-50, with two seals, CR, greased
1) fs = factor
2) s = stroke

Definition of dynamic load ratings

technical illustration-R102925034-Linear set (aluminum), CT-50, with two seals, CR, greased

Dimensions

Ød

mm

12 16 20 25 30 40 50

D

mm

19 24 28 35 40 52 62

A

mm

40 45 53 62 67 87 103

E1

29 mm ±0.15 34 mm ±0.15 40 mm ±0.15 48 mm ±0.15 53 mm ±0.15 69 mm ±0.15 82 mm ±0.15

E2

35 mm ±0.15 40 mm ±0.15 45 mm ±0.15 55 mm ±0.15 70 mm ±0.15 85 mm ±0.15 100 mm ±0.15

H

mm

17 19 23 27 30 39 47

Tolerance for H 1)

µm

+ 24
0
+ 25
0
+ 26
0
+ 14
- 12

H1

mm

33 38 45 54 60 76 92

H4

mm

11 13 15 17 19 24 30

L

mm

60 65 85 105 125 145

N1

mm

16 18 22 26 29 38 46

N2

mm

11 13 18 22 26

S 2)

mm

4.3 5.3 6.6 8.4 10.5

S1

M5 M6 M8 M10 M12
1) In relation to Ø d.
2) Fixing screws ISO 4762-8.8

Legend

Symbol

Description

Unit

Ød

Shaft diameters

mm

C/C0

Main direction of loading

ML0

Static torsional moment laod capacity

Nm

Life expectancy calculation

General mounting instructions

Initial lubrication

Linear bushings come with initial lubrication. Grease the Linear Bushings before use. Service life data is based on initial lubrication and relubricated Linear Bushings.

technical illustration-R102925034-Linear set (aluminum), CT-50, with two seals, CR, greased

Lubrication

Directives and standards